GIT (Glucose Infusion Test): Polycentric Evaluation of a New Test for Vascular Access Recirculation

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Introduction. Vascular access recirculation (AR), which is often unacknowledged, remains an important cause of inadequate dialytic dose. The glucose infusion test (GIT) is a new method for detecting and quantifying AR. This paper reports on a polycentric evaluation of the new test and a comparison with the classical Urea-test (UT). Methods. GIT protocol comprises withdrawal from the arterial port (sample A), injection into the venous drip chamber of 1 g glucose in 4 seconds, withdrawal from the arterial port (sample B) continuously from 13 to 17 seconds. Glucose is determined on A and B by a reflectance photometer. If B = A then there is no recirculation. If B exceeds A by at least 20 mg/dl there is recirculation. AR quantification: AR% = (B-A) / 20. GIT was performed on 623 patients from eleven dialysis centers to screen the patients for AR. Subsequently, GIT and Urea-test (UT) were compared in 189 paired tests. The reproducibility of GIT and UT was studied in 28 paired tests performed in sequence. Results. The screening test by GIT was positive in 68 cases (11 %). The majority of positivities was found in central venous catheters (CVC, 27/50 cases, 54 %), whereas only 7 % of artero-venous fistulas (AVF) were positive. In the CVC group, Tesio catheters were more frequently positive compared to Dual Lumen Catheters (64 % vs. 29 %). The comparison GIT - UT showed that results matched in 162 tests (79 negative and 83 positive both by GIT and UT), showing that on the grounds of UT, GIT has high sensitivity and specificity. In 27 tests GIT was positive, but UT negative. This disagreement is due to the different minimal limit of detection, 1 % for GIT and 5% for UT. The reproducibility was greater with GIT than with UT with a lower D% (respectively -0.6 +/- 2.5 and -0.4 +/- 6.1 %, p<0.001) and a lower coefficient of variation (17 vs 33 %). Conclusions. The screening of 623 patients by GIT confirmed that AR in AVF is normally absent, whereas an un-expectedly high frequency of moderate AR in CVC was found. The GIT-UT comparison showed that the new test is simple and immediate, and gives results with higher accuracy, sensitivity and reproducibility than UT.

Similar Papers
  • Research Article
  • Citations31

Glucose infusion test: A new screening test for vascular access recirculation

  • May 01, 2000
  • Kidney International
  • Alberto Magnasco +4
  • Research Article

The value of urea-based recirculation in screening arteriovenous fistula stenosis among end stage renal disease patients undergoing maintenance hemodialysis

  • Dec 31, 2024
  • MedPharmRes
  • Hien Van Pham +3
  • Supplementary Content
  • Citations31

A Review Article: Access Recirculation Among End Stage Renal Disease Patients Undergoing Maintenance Hemodialysis

  • Jan 01, 2013
  • Nephro-urology Monthly
  • Abbasali Zeraati +2
  • Research Article
  • Citations21

Identifying Hemodialysis Catheter Recirculation Using Effective Ionic Dialysance

  • Sep 01, 2012
  • ASAIO Journal
  • Jennifer Tan +4
  • Research Article
  • Citations13

Formation and Spontaneous Closure of an Arteriovenous Fistula After Transvenous Pacemaker Placement

  • Aug 01, 1991
  • Chest
  • Michael A Zullo +2
  • Research Article
  • Citations28

Factors influencing the prevalence of central venous catheter use in a Canadian haemodialysis centre

  • Jun 14, 2008
  • Nephrology Dialysis Transplantation
  • J Graham +4
  • Research Article

Prevalence of Access Recirculation in Prevalent Arterio-Venous (A-V) Fistula Hemodialysis Patients and Its Effect on Hemodialysis Adequacy

  • Apr 27, 2019
  • The Egyptian Journal of Hospital Medicine
  • Michael Mamdouh Fakhry +2
  • Research Article
  • Citations12

The influence of between‐needle cannulation distance on the efficacy of hemodialysis treatments

  • Jul 18, 2011
  • Hemodialysis International
  • Christine Rothera +4
  • Research Article
  • Citations4

Effects of Arterial Needle Placement in Arteriovenous Fistula on Dialysis Adequacy of End-Stage Renal Disease Patients Undergoing Maintenance Hemodialysis

  • Nov 08, 2016
  • Journal of Nursing &amp; Healthcare
  • Research Article

#5103 VASCULAR ACCESS AT HEMODIALYSIS INITIATION: A REPORT FROM THE ROMANIAN RENAL REGISTRY

  • Jun 14, 2023
  • Nephrology Dialysis Transplantation
  • Gabriel Stefan +2
  • Research Article
  • Citations2

Cross-sectional study of quality of life in relation with vascular access in hemodialysis patients

  • Jun 14, 2023
  • Revista Colombiana de Nefrología
  • Maria Maldonado +10
  • Research Article
  • Citations3

The effect of early conversion from central venous catheter to arteriovenous fistula on hospitalization and mortality in incident haemodialysis patients.

  • Aug 28, 2023
  • The journal of vascular access
  • Wenyuan Gan +5
  • Research Article
  • Citations51

Arteriovenous Fistulae as an Alternative to Central Venous Catheters for Delivery of Long-Term Home Parenteral Nutrition

  • Feb 10, 2009
  • Gastroenterology
  • Michelle W.J Versleijen +8
  • Research Article
  • Citations20

Haemodialysis recirculation measured using a femoral artery sample

  • Jan 01, 1994
  • Nephrology Dialysis Transplantation
  • Tom Buur +1
  • Research Article
  • Citations149

Vascular Access for Hemodialysis Patients: New Data Should Guide Decision Making.

  • Apr 11, 2019
  • Clinical Journal of the American Society of Nephrology
  • Michael Allon
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.