• Home
  • Search
  • Hadronic vs. electromagnetic pulse shape discrimination in CsI(Tl) for high energy physics experiments
  • Open Access IconOpen Access
  • Cite Icon11
  • https://doi.org/10.1088/1748-0221/13/03/p03018Copy DOI Icon

Hadronic vs. electromagnetic pulse shape discrimination in CsI(Tl) for high energy physics experiments

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Pulse shape discrimination using CsI(Tl) scintillators to perform neutral hadron particle identification is explored with emphasis towards application at high energy electron-positron collider experiments. Through the analysis of the pulse shape differences between scintillation pulses from photon and hadronic energy deposits using neutron and proton data collected at TRIUMF, it is shown that the pulse shape variations observed for hadrons can be modelled using a third scintillation component for CsI(Tl), in addition to the standard fast and slow components. Techniques for computing the hadronic pulse amplitudes and shape variations are developed and it is shown that the intensity of the additional scintillation component can be computed from the ionization energy loss of the interacting particles. These pulse modelling and simulation methods are integrated with GEANT4 simulation libraries and the predicted pulse shape for CsI(Tl) crystals in a 5 × 5 array of 5 × 5 × 30 cm3 crystals is studied for hadronic showers from 0.5 and 1 GeV/c KL0 and neutron particles. Using a crystal level and cluster level approach for photon vs. hadron cluster separation we demonstrate proof-of-concept for neutral hadron detection using CsI(Tl) pulse shape discrimination in high energy electron-positron collider experiments.

Similar Papers
  • Research Article
  • Citations21

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

  • Aug 22, 2020
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • S Longo +17
  • Research Article
  • Citations13

Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon

  • May 01, 2018
  • Journal of Instrumentation
  • E Hogenbirk +5
  • Research Article
  • Citations4

Self-Induced Transparency Phenomena of Single-Mode Pulse Laser Propagating in a Thick Ytterbium Vapor Column

  • Mar 01, 2000
  • Japanese Journal of Applied Physics
  • Jonghoon Yi +3
  • Research Article
  • Citations62

Fast neutron and gamma ray pulse shape discrimination in EJ-276 and EJ-276G plastic scintillators

  • Mar 01, 2020
  • Journal of Instrumentation
  • M Grodzicka-Kobylka +8
  • Research Article
  • Citations34

Calibration of a CsI(Tl) crystal with nuclear recoils and pulse shape measurements for dark matter detection

  • Sep 01, 1999
  • Astroparticle Physics
  • S Pécourt +10
  • Research Article
  • Citations123

Electron drift mobility in amorphous Si: H

  • Jul 01, 1986
  • Philosophical Magazine B
  • J M Marshall +2
  • Research Article
  • Citations13

The combined application of principal component analysis and decision tree in nuclear pulse shape discrimination

  • Aug 05, 2019
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Zhenhua Zhang +7
  • Research Article
  • Citations38

Light Pulse Shapes in Liquid Scintillators Originating From Gamma-Rays and Neutrons

  • Dec 01, 2010
  • IEEE Transactions on Nuclear Science
  • T Szczesniak +11
  • PDF
  • Research Article
  • Citations15

Evaluation of the Constant Fraction Time-Over-Threshold (CF-TOT) method for neutron-gamma pulse shape discrimination

  • May 01, 2022
  • Journal of Instrumentation
  • A Roy +6
  • Research Article
  • Citations21

Measurement of 222Rn by absorption in plastic scintillators and alpha/beta pulse shape discrimination

  • Feb 03, 2016
  • Applied Radiation and Isotopes
  • Krasimir K Mitev
  • Research Article
  • Citations1

A model for the secondary scintillation pulse shape from a gas proportional scintillation counter

  • Mar 01, 2016
  • Journal of Instrumentation
  • K Kazkaz +1
  • PDF
  • Research Article
  • Citations12

Effect of process parameters on pulsed laser welding of AA5083 alloy using response surface methodology and pulse shape variation

  • Mar 18, 2022
  • The International Journal of Advanced Manufacturing Technology
  • Mariane Chludzinski +4
  • Research Article
  • Citations7

Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system: first results

  • Aug 17, 2012
  • Journal of Radioanalytical and Nuclear Chemistry
  • C E Aalseth +11
  • Conference Article

Termination effect on pulse shape discrimination

  • Jan 01, 2007
  • Andy Li +4
  • Research Article
  • Citations2

Rectify the effect of measurement in survival probability of the ground vibrational state in diatomic molecule

  • Jul 10, 2019
  • International Journal of Modern Physics B
  • Bikram Nath +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.