Abstract

<p>Background: The main goal of ultrasound therapy is to have clinical effects in the tissue without damage to the intervening and surrounding tissues. Treatments have been developed for both in vitro and in clinical applications. HIFU therapy is one of these. Non-invasive surgeries, such as HIFU, have been developed to treat tumors or to stop bleeding. In this approach, an adequate imaging method for monitoring and controlling the treatment is required. Methods: In this paper, an adaptive compressive sensing representation of ultrasound RF echo signals is presented based on empirical mode decomposition (EMD). According to the different numbers of intrinsic mode functions (IMFs) produced by the EMD, the ultrasound signals is adaptively compressive sampled in the source and then adaptively reconstructed in the receiver domains. In this paper, a new application of compressive sensing based on EMD (CS-EMD) in the monitoring of high-intensity focused ultrasound (HIFU) treatment is presented. Non-invasive surgeries such as HIFU have been developed for various therapeutic applications. In this technique, a suitable imaging method is necessary for monitoring of the treatment to achieve adequate treatment safety and efficacy. So far, several methods have been proposed, such as ultrasound radiofrequency (RF) signal processing techniques, and imaging methods such as X-ray, MRI, and ultrasound to monitor HIFU lesions. Results:In this paper, a CS-EMD method is used to detect the HIFU thermal lesion dimensions using different types of wavelet transform. The results of the processing on the real data demonstrate the potential for this technique in image-guided HIFU therapy. Conclusions: In this study, a new application of compressive sensing in the field of monitoring of the HIFU treatment is presented. To the best of our knowledge, so far no studies on compressive sensing have been carried out in the monitoring of the HIFU. Based on the results obtained, it was showed that the number of measurements and Intrinsic Mode Functions have the function of noise reduction. In addition, results were shown that the successful reconstruction of the compressive sensing signals can be gained using a threshold based algorithm. To this end, in this paper it was shown that by selecting an suitable number of measurements, the sparse transform, and a thresholding algorithm, we can achieve a more accurate detection of the HIFU thermal lesion size. </p>

Similar Papers
  • Research Article
  • Citations6

High-Intensity Focused Ultrasound Lesion Detection Using Adaptive Compressive Sensing Based on Empirical Mode Decomposition

  • Jan 01, 2019
  • Journal of Medical Signals and Sensors
  • Hamid Behnam +2
  • Preprint Article

High-Intensity Focused Ultrasound Lesion Detection Using Adaptive Compressive Sensing Based on Empirical Mode Decomposition

  • Jan 09, 2023
  • Hadi Ghasemifard +2
  • Conference Article
  • Citations41

Using the ATL HDI 1000 to collect demodulated RF data for monitoring HIFU lesion formation

  • May 23, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ajay Anand +6
  • Research Article
  • Citations22

High-Intensity Focused Ultrasound Thermal Lesion Detection Using Entropy Imaging of Ultrasound Radio Frequency Signal Time Series

  • Jan 01, 2018
  • Journal of Medical Ultrasound
  • Hamid Behnam +3
  • Research Article
  • Citations2

Enhancement of HIFU Effect by Simultaneous Short Course Degarelix for Early Stage Prostate Cancer: A Pilot Study

  • Jan 01, 2016
  • Open Journal of Urology
  • Teiichiro Aoyagi +1
  • Conference Article

Design of a Time-Frequency Algorithm for Automatic Eeg Artifact Removal

  • Jan 01, 2016
  • Boualem Boashash +2
  • Research Article
  • Citations70

Interpretation of mechanical signals using an improved Hilbert–Huang transform

  • Nov 29, 2007
  • Mechanical Systems and Signal Processing
  • Wen-Xian Yang
  • Conference Article

High Intensity Focused Ultrasound Transducer Using Inversion Layer Technique for Ultrasound Therapy

  • Apr 10, 2017
  • Chan Yuk Park +3
  • Research Article
  • Citations5

High-Intensity Focused Ultrasound Therapy Versus Coblation for the Treatment of Inferior Turbinate Hypertrophy: A Clinical Trial

  • Feb 13, 2023
  • Clinical and Experimental Otorhinolaryngology
  • Hyung Gu Kim +5
  • Conference Article

Integrated photoacoustic/ultrasound/HFU system based on a clinical ultrasound imaging platform

  • Feb 19, 2018
  • Photons Plus Ultrasound: Imaging and Sensing 2018
  • Jeesu Kim +3
  • Research Article

ПРОФИЛАКТИКА РАССТРОЙСТВ МОЧЕИСПУСКАНИЯ ПОСЛЕ HIFU-ТЕРАПИИ РАКА ПРЕДСТАТЕЛЬНОЙ ЖЕЛЕЗЫ

  • Jul 25, 2014
  • Oncourology (Russian Society of Oncourologists)
  • А Ю Шестаев +4
  • Research Article
  • Citations4

A new approach for embedding dimension determination based on empirical mode decomposition

  • Oct 12, 2012
  • Kybernetes
  • Shulin Liu +4
  • Conference Article
  • Citations16

Therapy planning and monitoring of tissue ablation by high intensity focused ultrasound (HIFU) using imaging and simulation

  • Aug 01, 2008
  • Viren Amin +5
  • Research Article
  • Citations5

A modified EMD method for detecting and mitigating narrow-band RFI in SAR data

  • Apr 24, 2022
  • Remote Sensing Letters
  • Ning Li +3
  • Research Article
  • Citations14

Real-Time Reconstruction of HIFU Focal Temperature Field Based on Deep Learning.

  • Jan 01, 2024
  • BME Frontiers
  • Shunyao Luan +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.