• Home
  • Search
  • High precision innovative micropump for artificial pancreas
  • Cite Icon5
  • https://doi.org/10.1117/12.2036068Copy DOI Icon

High precision innovative micropump for artificial pancreas

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech’s MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.

Similar Papers
  • PDF
  • Research Article
  • Citations38

Insulin Micropump with Embedded Pressure Sensors for Failure Detection and Delivery of Accurate Monitoring

  • Nov 18, 2014
  • Micromachines
  • Dimitry Dumont-Fillon +3
  • Research Article
  • Citations22

Type 1 Diabetes Mellitus

  • May 01, 2013
  • Pediatrics In Review
  • Justin M Gregory +2
  • Abstract

94 Evaluation of use of technology and its impact on glycemic control in children & young people with type1 diabetes mellitus

  • Apr 01, 2021
  • BMJ Paediatrics Open
  • Suman Fathima +1
  • Research Article
  • Citations2

Disaster planning in diabetes

  • Jan 01, 2021
  • Practical Diabetes
  • Rowan Hillson
  • Research Article
  • Citations10

User Acceptability and Perceived Benefits of New Reports in CareLink Pro 3.0 Therapy Management Software for Diabetes

  • Mar 01, 2012
  • Journal of Diabetes Science and Technology
  • John B Welsh +4
  • Research Article
  • Citations8

The separation of insulin pump hardware and software - a novel and low-cost approach to insulin pump design

  • Jan 01, 2021
  • IFAC-PapersOnLine
  • Matthew Payne +5
  • Abstract

S131. Reducing glucose variability with continuous subcutaneous insulin infusion is associated with reversal of axonal dysfunction in type 1 diabetes mellitus

  • May 01, 2018
  • Clinical Neurophysiology
  • Jordan Kamel +4
  • Research Article
  • Citations48

Evolution of Devices in Diabetes Management

  • Jun 01, 2011
  • Diabetes Technology & Therapeutics
  • Alfred Penfornis +2
  • Research Article
  • Citations3

Advances in exercise, physical activity, and diabetes mellitus.

  • Feb 01, 2015
  • Diabetes Technology & Therapeutics
  • Sepideh Mohajeri +1
  • Research Article
  • Citations3

Recent Exposure to Hypoglycemia Increases Glucose Variability Following a Hyper/Hypoglycemic Metabolic Challenge in T1D.

  • Sep 25, 2017
  • Journal of Diabetes Science and Technology
  • Chiara Fabris +5
  • Book Chapter

Components of an Artificial Pancreas System

  • Jan 01, 2018
  • Ali Cinar +1
  • Research Article
  • Citations6

Evaluation of a New Digital Automated Glycemic Pattern Detection Tool

  • Nov 01, 2017
  • Diabetes Technology & Therapeutics
  • María José Comellas +10
  • Research Article
  • Citations61

A Remotely Programmable Insulin Delivery System

  • Apr 02, 1982
  • JAMA
  • David S Schade
  • Research Article
  • Citations24

The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability.

  • Jan 16, 2019
  • Diabetes Technology & Therapeutics
  • Stacey M Anderson +20
  • Research Article
  • Citations1

(Invited) MEMS Capping By Anodic Bonding of Evaporated Glass Thin Films

  • Sep 01, 2016
  • Electrochemical Society Meeting Abstracts
  • Ulli Hansen +3
Cactus Communications logo