First steps towards a high-Tc squid amplifier
- Sep 01, 1996
- Applied Superconductivity
- J Ramos + 6 more +6
First steps towards a high-Tc squid amplifier
Highly sensitive DC SQUID magnetometers and gradiometers with flux focusers instead of traditional coupling coils were designed and experimentally tested. All refractory material DC SQUIDs with shunted Nb-AlO/sub x/-Nb tunnel junctions were used. The outer dimension of the square washer electrode was 2.5 mm and the inner 70 mu m. A wide superconducting washer concentrates the magnetic flux by twenty times, and a flux sensitivity of about 20 nT/ Phi /sub 0/ can be realized without any input coil. The application of the additional 14-mm diameter flux focuser has increased the flux concentration by four times. As a result, a magnetic field resolution of 10 fT/ square root Hz has been achieved; this figure corresponds to the flux resolution about 2*10/sup -6/ Phi /sub 0// square root Hz. Connecting the additional flux focuser to the compensation coils, one can create gradiometers of both the first and higher orders. The flux concentration coefficients were calculated for the several possible mutual positions of the SQUID washer and the focuser. The influence of the two focusers on each other was calculated. The experimental test makes it possible to get the correct relation between the effective area of the SQUID with a focuser and the outer sizes of the focuser. The first-order gradiometer, consisting of the rectangular focuser and compensation coil connected to it, has been experimentally verified. The results demonstrate that sensitivity of the magnetometers and gradiometers with flux focuses are very attractive for multichannel biomagnetic systems and for high-temperature SQUID magnetometers.
First steps towards a high-Tc squid amplifier
First steps towards a high-Tc squid amplifier
Tunnel junction dc SQUID: Fabrication, operation, and performance
We describe the theory, fabrication, operation, and performance of a cylindrical dc SQUID made with shunted Nb-NbOx-Pb Josephson tunnel junctions. The SQUID is current-biased at a nonzero voltage, and modulated with a 100 kHz flux. The 100 kHz voltage developed across the SQUID is amplified by a cooled, resonantLC circuit that optimally couples the SQUID impedance to the input of a room-temperature FET preamplifier. The SQUID is operated in a flux-locked loop with a dynamic range in a 1-Hz bandwidth of ±3×106. The 3-dB rolloff frequency for the loop response is typicalty 2 kHz, and the slewing rate is generally 2×104 φ0 sec−1. A typical flux noise power spectrum for a SQUID at 4.2 K in a superconducting shield is presented. Above 2×10−2 Hz the spectrum is white and has an rms value of 3.5×10−5 φ0 Hz−1/2. The white noise is intrinsic to the sensor and is close to the theoretical limit set by Johnson noise in the shunts. At lower frequencies, the power spectrum is approximately 10−10 (1 Hz/f) φ 0 2 Hz−1, wheref is the frequency. This value is approximately two orders of magnitude greater than the calculated 1/f noise in the tunnel junctions. The factors contributing to the long-term drift of the SQUID are discussed. By regulating the temperature of the helium bath we have achieved a drift rate of 2×10−5 φ0 h−1 over a 20-h period. A detailed description is given of the coupling efficiency of various input coils wound on the SQUID. The effects of coupling between the input coil, the SQUID, and the feedback (modulation) coil are described, and measurements of the coupling parameters reported. The energy resolution of the SQUID with respect to a current in a 24-turn input coil is 7×10−30 J Hz−1 for frequencies at which the flux noise has a white power spectrum. In terms of energy resolution, the SQUID has a better performance in the 1/f noise region that that of any SQUID previously reported in the literature. The long-term drift over an extended period also represents the lowest value yet reported.
Read moreMagneto-Optical Ceramics with High Transparency for Highly Sensitive Magnetometer via Quantum Weak Measurement.
Sensitive magnetometer technology is desirable for biomagnetic field detection and geomagnetic field measuring. Signal amplification materials such as magneto-optical crystals or ceramics are crucial for enhancing detection sensitivity, but severe optical scattering and low Verdet constant further limit its application. To develop high-sensitivity magnetometers for quantum weak measurement schemes, we have conducted investigations on the powder calcining dynamics and prepared a series of high-optical-quality (Ho/Dy)2Zr2O7 transparent ceramic samples. The Verdet constant of magneto-optical materials was measured across a continuous wavelength spectrum, exhibiting a peak at 283 ± 5 rad/(T·m). We further established an electron transition mechanism to elucidate the exceptional magneto-optical attributes of dysprosium. In addition, samples demonstrated superior performance in weak-value amplification, reaching a low detectable magnetic field threshold of 3.5 × 10-8 T and continuously worked over 6 h with high stability. Our work developed a highly sensitive magnetometer using optimized magneto-optical ceramics and provided guidance on design, fabrication, and application for magneto-optical ceramics in quantum weak measurement.
Read moreMeasured performance parameters of gradiometers with digital output
A planar first-order gradiometer and a DC SQUID (superconducting quantum interference device) comparator have been integrated on the same 6*6 mm/sup 2/ chip in Nb-Nb/sub 2/O/sub 5/-PbInAu technology and operated in a flux-locked loop. Owing to the digital gradiometer output, a very low flux noise of 7*10/sup -7/ phi /sub 0// square root Hz, a coupled noise energy of 34 times Planck's constant h, and a gradient noise of 3.8 pT/m square root Hz have been achieved in the white noise region above about 60 Hz. In spite of the very low flux noise, a maximum slew rate of 1.5*10/sup 5/ phi /sub 0//s at a signal frequency of 4 kHz has been measured. A simple modulation scheme has been developed to cancel Josephson junction critical-current fluctuations, yielding 4.5*10/sup -6/ phi /sub 0// square root Hz at 0.1 Hz.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Read more<title>Faraday effect sensors for magnetic field and electric current</title>
Recent research at NIST has greatly extended the capabilities of Faraday effect sensors for both magnetic field and electric current measurements. Current sensors using single-mode optical fiber show temperature stability near material limits, and are approaching commercial availability for application in the power industry. The Faraday effect in iron garnets shows great promise for measuring current at low levels and/or high speeds. Sensors with noise equivalent currents of about 200 nA/(root)Hz have been demonstrated. Magnetic field sensors using iron garnets and flux concentration, have led to sensors with noise equivalent magnetic fields in the range of 1 pT/(root)Hz.
Read moreLight intensity fluctuation insensitive faraday polarimeter for atomic magnetometer
Atomic Magnetometer has ranked the highest sensitive magnetometer in recent years. To realize a high performance atomic magnetometer, a well designed polarimeter is required to detect the atomic spin precession. Among various polarimeter techniques available, faraday polarimeter is suitable for high sensitive atomic magnetometer application due to its high angular sensitivity at low frequency range. However, this polarimeter is sensitive to light intensity fluctuation which will decrease the atomic magnetometer sensitivity and its long time performance. Instead of utilizing a light intensity feedback controlled system to active stabilize the light intensity, this paper proposed a faraday polarimeter with light intensity fluctuation compensation capability. The structure and mathematic model of this polarimeter was analyzed, experimental tests were performed. With this polarimeter, the light intensity fluctuation was decreased significantly to 0.001%, and an angular sensitivity of 10−8 rad/Hz1/2 has been achieved.
Read morePerformance of high-T/sub c/ SQUID magnetometers for application in biomagnetism
Single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of MCG measurements in magnetically disturbed environment. Two types of magnetometers have been designed and fabricated using 10 mm/spl times/10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system with the SQUID magnetometers with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clear magnetocardiogram in a weak magnetic-shield-room.
Read moreDesign of HTS dc SQUID Gradiometer for Application in Nondestructive Evaluation and Biomagnetism
We investigated dc SQUID structures for operations in planar high T C-gradiometer structures for different applications in unshielded evironments. The developement of dc SQUIDs for practical applications is determined by the type of sensor in which the SQUID will be used. Generally we can distinguish between different instance between magnetically and galvanically coupled sensor layouts.
Read moreA tightly coupled dc SQUID with an intermediary transformer
A tightly coupled dc SQUID with an intermediary transformer
Airborne gamma-ray spectrometer and magnetometer survey: north/south tieline. Final report
An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted along the 99/sup 0/ longitude meridian from the Canadian border southward to the Mexican border. A total of 1555 line miles of geophysical data were acquired and, subsequently, compiled. The north-south tieline was flown as part of the National Uranium Resources Evaluation. NURE is a program of the US Department of Energy's Grand Junction, Colorado, office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States.
Read moreAirborne gamma-ray spectrometer and magnetometer survey, New Rockford Quadrangle, North Dakota. Final report
An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2/sup 0/ x 1/sup 0/ NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2/sup 0/ x 1/sup 0/ NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the New Rockford map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1397 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States.
Read moreAirborne gamma-ray spectrometer and magnetometer survey Coos Bay, Oregon. Final report
During the months of August, September, and October of 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over ten (10) areas over northern California and southwestern Oregon. These include the 2/sup 0/ x 1/sup 0/ NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1/sup 0/ x 2/sup 0/ areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Coos Bay, Oregon, map area. Line spacing was generally six miles for east/west traverses and eighteen miles for north/south tie lines over the northern one-half of the area. Traverses and tie lines were flown at three miles and twelve miles respectively over the southern one-half of the area. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 863.8 line miles are in this quadrangle.
Read moreThe sensitivity test of JOM-2 overhauser magnetometer
Overhauser magnetometer is a detection instrument of the geomagnetic field. The sensitivity of Overhauser magnetometer is one of the important technical parameters. This paper introduces a high sensitivity and low power consumption JOM-2 Overhauser magnetometer based on Overhauser effect. A detailed description of the system controlled by DSP+CPLD is provided from three aspects: design principle, system composition and the sensitivity experimental test. In order to explore the sensitivity of JOM-2 under ideal and practical conditions, we give the test methods and results. Under ideal conditions, we use a DDS function signal generator to make a static magnetic field whose frequency and amplitude are constant and the signal to noise ratio (SNR) is high. And we use an analog function signal generator to generate a time-dependent magnetic field. These experimental results indicate that the ideal sensitivity of the JOM-2 Overhauser magnetometer is up to 0.003nT. Under practical conditions, the sensitivity can reach 0.043nT, which confirms that the JOM-2 Overhauser magnetometer is sensitive to geomagnetic field measurement.
Read moreAirborne gamma-ray spectrometer and magnetometer survey: Alturas quadrangle, California. Final report
An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten (10) areas over northern California and southwestern Oregon. These include the 2/sup 0/ x 1/sup 0/ NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1/sup 0/ x 2/sup 0/ areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Alturas, California, map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately eighteen (18) miles apart. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1631.6 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States.
Read moreAirborne gamma-ray spectrometer and magnetometer survey: Platoro Caldera Detail Survey, Durango quadrangle (Colorado). Final report
Between October 18 and November 7, 1978, a high sensitivity airborne gamma-ray spectrometer and magnetometer survey was conducted over the Durango Detailed Survey Area No. 3, which is centered about 20 miles northeast of Pagosa Springs, Colorado and located within the San Juan Mountains. The study was carried out as part of the Aerial Radiometric and Magnetic Reconnaissance Survey Program, designed to map the regional distribution of the natural radioelements for the principal rock units of the United States in support of the National Uranium Resource Evaluation (NURE) program.
Read more