• Home
  • Search
  • High sensitive magnetometers and gradiometers based on DC SQUIDs with flux focuser
  • Cite Icon15
  • https://doi.org/10.1109/20.133832Copy DOI Icon

High sensitive magnetometers and gradiometers based on DC SQUIDs with flux focuser

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Highly sensitive DC SQUID magnetometers and gradiometers with flux focusers instead of traditional coupling coils were designed and experimentally tested. All refractory material DC SQUIDs with shunted Nb-AlO/sub x/-Nb tunnel junctions were used. The outer dimension of the square washer electrode was 2.5 mm and the inner 70 mu m. A wide superconducting washer concentrates the magnetic flux by twenty times, and a flux sensitivity of about 20 nT/ Phi /sub 0/ can be realized without any input coil. The application of the additional 14-mm diameter flux focuser has increased the flux concentration by four times. As a result, a magnetic field resolution of 10 fT/ square root Hz has been achieved; this figure corresponds to the flux resolution about 2*10/sup -6/ Phi /sub 0// square root Hz. Connecting the additional flux focuser to the compensation coils, one can create gradiometers of both the first and higher orders. The flux concentration coefficients were calculated for the several possible mutual positions of the SQUID washer and the focuser. The influence of the two focusers on each other was calculated. The experimental test makes it possible to get the correct relation between the effective area of the SQUID with a focuser and the outer sizes of the focuser. The first-order gradiometer, consisting of the rectangular focuser and compensation coil connected to it, has been experimentally verified. The results demonstrate that sensitivity of the magnetometers and gradiometers with flux focuses are very attractive for multichannel biomagnetic systems and for high-temperature SQUID magnetometers.

Similar Papers
  • Research Article

First steps towards a high-Tc squid amplifier

  • Sep 01, 1996
  • Applied Superconductivity
  • J Ramos +6
  • Research Article
  • Citations261

Tunnel junction dc SQUID: Fabrication, operation, and performance

  • Oct 01, 1976
  • Journal of Low Temperature Physics
  • John Clarke +2
  • Research Article
  • Citations2

Magneto-Optical Ceramics with High Transparency for Highly Sensitive Magnetometer via Quantum Weak Measurement.

  • Jul 22, 2024
  • ACS applied materials & interfaces
  • Wenhan Han +6
  • Research Article
  • Citations36

Measured performance parameters of gradiometers with digital output

  • Mar 01, 1989
  • IEEE Transactions on Magnetics
  • D Drung +4
  • Conference Article
  • Citations2

<title>Faraday effect sensors for magnetic field and electric current</title>

  • Nov 01, 1994
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Gordon W Day +3
  • Conference Article
  • Citations2

Light intensity fluctuation insensitive faraday polarimeter for atomic magnetometer

  • Aug 01, 2011
  • Qin Jie +2
  • Research Article
  • Citations3

Performance of high-T/sub c/ SQUID magnetometers for application in biomagnetism

  • Jun 01, 2003
  • IEEE Transactions on Appiled Superconductivity
  • In-Seon Kim +4
  • Book Chapter
  • Citations3

Design of HTS dc SQUID Gradiometer for Application in Nondestructive Evaluation and Biomagnetism

  • Jan 01, 2001
  • F Schmidls +2
  • Research Article
  • Citations22

A tightly coupled dc SQUID with an intermediary transformer

  • Oct 04, 2001
  • Physica C: Superconductivity
  • V Polushkin +4
  • Single Report

Airborne gamma-ray spectrometer and magnetometer survey: north/south tieline. Final report

  • May 01, 1981
  • Bendix Field Engineering Corp., Grand Junction, Co (Usa) +1
  • Single Report
  • Citations1

Airborne gamma-ray spectrometer and magnetometer survey, New Rockford Quadrangle, North Dakota. Final report

  • Apr 01, 1981
  • Western Geophysical Co Of America, Houston, Tx Aero Service Div
  • Single Report

Airborne gamma-ray spectrometer and magnetometer survey Coos Bay, Oregon. Final report

  • May 01, 1981
  • Western Geophysical Co Of America, Houston, Tx Aero Service Div
  • Conference Article
  • Citations1

The sensitivity test of JOM-2 overhauser magnetometer

  • Jun 01, 2017
  • Jinglun Cai +3
  • Single Report

Airborne gamma-ray spectrometer and magnetometer survey: Alturas quadrangle, California. Final report

  • May 01, 1981
  • Bendix Field Engineering Corp., Grand Junction, Co (Usa) +1
  • Single Report

Airborne gamma-ray spectrometer and magnetometer survey: Platoro Caldera Detail Survey, Durango quadrangle (Colorado). Final report

  • Feb 01, 1980
  • Not Available
Cactus Communications logo