Abstract

Monte Carlo simulations (MCS) represent a fundamental approach to modelling the photon interactions in positron emission tomography (PET). A variety of PET-dedicated MCS tools are available to assist and improve PET imaging applications. Of these, GATE has evolved into one of the most popular software for PET MCS because of its accuracy and flexibility. However, simulations are extremely time-consuming. The use of graphics processing units (GPU) has been proposed as a solution to this, with reported acceleration factors about 400–800. These factors refer to GATE benchmarks performed on a single CPU core. Consequently, CPU-based MCS can also be easily accelerated by one order of magnitude or beyond when exploiting multi-threading on powerful CPUs. Thus, CPU-based implementations become competitive when further optimisations can be achieved. In this context, we have developed a novel, CPU-based software called the PET physics simulator (PPS), which combines several efficient methods to significantly boost the performance. PPS flexibly applies GEANT4 cross-sections as a pre-calculated database, thus obtaining results equivalent to GATE. This is demonstrated for an elaborated PET scanner with 3-layer block detectors. All code optimisations yield an acceleration factor of ≈20 (single core). Multi-threading on a high-end CPU workstation (96 cores) further accelerates the PPS by a factor of 80. This results in a total speed-up factor of ≈1600, which outperforms comparable GPU-based MCS by a factor of ≳2. Optionally, the proposed method of coincidence multiplexing can further enhance the throughput by an additional factor of ≈15. The combination of all optimisations corresponds to an acceleration factor of ≈24 000. In this way, the PPS can simulate complex PET detector systems with an effective throughput of 106 photon pairs in less than 10 milliseconds.

Similar Papers
  • Conference Article
  • Citations3

Clinical investigations of a 4D ML reconstruction strategy for PET-based treatment verification in ion beam therapy

  • Nov 01, 2014
  • Chiara Gianoli +7
  • Research Article
  • Citations10

SU‐E‐I‐68: Fast and Accurate Estimation of Organ Doses in Medical Imaging Using a GPU‐Accelerated Monte Carlo Simulation Code

  • Jun 01, 2011
  • Medical Physics
  • A Badal +1
  • PDF
  • Research Article
  • Citations11

GPU-accelerated Monte Carlo based scatter correction in brain PET/MR.

  • Jul 29, 2014
  • EJNMMI Physics
  • Michaela Gaens +5
  • Research Article

TU‐C‐214‐12: On‐Board PET with Tomotherapy Using Open Dual Ring Geometry with Consideration to DOI Effect

  • Jun 01, 2011
  • Medical Physics
  • N Darwish +3
  • Research Article
  • Citations32

Large-scale simulations on multiple Graphics Processing Units (GPUs) for the direct simulation Monte Carlo method

  • Aug 08, 2012
  • Journal of Computational Physics
  • C.-C Su +5
  • Conference Article
  • Citations2

Post-filtering of PET image based on noise characteristic and spatial sensitivity distribution

  • Oct 01, 2013
  • Ji Hye Kim +4
  • Research Article
  • Citations25

GPU accelerated MCMC for modeling terrorist activity

  • Apr 12, 2013
  • Computational Statistics & Data Analysis
  • Gentry White +1
  • PDF
  • Research Article
  • Citations1

GPU ACCELERATION OF DOPPLER BROADENING FOR NEUTRON TRANSPORT CALCULATIONS1

  • Jan 01, 2021
  • EPJ Web of Conferences
  • Paul E Burke +2
  • Research Article

SU-E-T-28: Accelerated Event-By-Event Microdosimetry Monte Carlo Simulations of Low Energy Electron and Proton on a CUDA-Enabled GPU

  • Jun 01, 2012
  • Medical Physics
  • G Kalantzis +3
  • Conference Article
  • Citations2

Comparison study of RPC and crystal based PET systems for hadron therapy monitoring

  • Oct 01, 2012
  • F Diblen +9
  • Research Article
  • Citations86

Clinical Application of In-Room Positron Emission Tomography for In Vivo Treatment Monitoring in Proton Radiation Therapy

  • Feb 04, 2013
  • International Journal of Radiation Oncology*Biology*Physics
  • Chul Hee Min +8
  • Conference Article
  • Citations5

Accelerating VNF-based Deep Packet Inspection with the use of GPUs

  • Jul 01, 2018
  • Igor M Araujo +3
  • Research Article
  • Citations14

GPU-Based PET Image Reconstruction Using an Accurate Geometrical System Model

  • Oct 01, 2012
  • IEEE Transactions on Nuclear Science
  • S Kinouchi +6
  • Conference Article
  • Citations20

Fast GPU-Assisted FEM Simulations of 3D Periodic TCSAW, IHP, and XBAR Devices

  • Oct 01, 2019
  • J Koskela +6
  • Research Article
  • Citations5

Active and passive cooling techniques of graphical processing units in automotive applications - a review

  • Jun 01, 2024
  • Engineering Research Express
  • S M Praveen +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.