Abstract

This paper addresses the miniaturization of microwave vector network analyzers (VNAs) and the future vision of the VNA on a chip. Therefore, a highly integrated two-port VNA with a multioctave bandwidth from 4 to 32 GHz is presented. The proposed system is based on a fully integrated radio-frequency frontend consisting of a two-port stimulus, a four-channel heterodyne receiver, and a wideband testset. The testset is comprised of on-chip multisection directional couplers. The chip is operated inside a hardware demonstrator using a 16-term calibration procedure. The measurement of arbitrary devices under test is in excellent agreement with commercial measurement equipment and showed a mean deviation from the reference measurement of 0.17 dB and 1.29° regarding the forward transmission of a coaxial 30-dB attenuator. The system and receiver dynamic ranges are 44-77 and 82-101 dB at a resolution bandwidth of 100 kHz over the full system bandwidth. The measurements are highly repeatable and are robust against drift over time. As a proof of concept, the developed integrated network analyzers are utilized in a biomedical sensing scenario with an external and an on-chip sensor. Both approaches showed good sensitivity regarding the mixture ratio of binary solutions of ethanol and methanol.

Similar Papers
  • Conference Article
  • Citations15

High-rsolution estimation of nlos indoor mimo channel with network analyzer based system

  • Sep 07, 2003
  • K Haneda +1
  • Research Article
  • Citations2

Measurement Technique for Symmetrical Reciprocal Three-Port Devices Using Two-Port Vector Network Analyzer

  • Oct 01, 2013
  • IEEE Transactions on Instrumentation and Measurement
  • Eric S Li +2
  • Research Article
  • Citations8

Life signal detection using an on-chip split-ring based solid state microwave sensor

  • Sep 29, 2014
  • Applied Physics Letters
  • H J Tang +7
  • Research Article

Limited-Information Signal De-Embedding for a Grain Bin Electromagnetic Imaging System

  • Jan 01, 2022
  • IEEE Open Journal of Antennas and Propagation
  • Seth Cathers +8
  • Research Article
  • Citations42

Novel and Simple High-Frequency Single-Port Vector Network Analyzer

  • Mar 01, 2010
  • IEEE Transactions on Instrumentation and Measurement
  • M.A Abou-Khousa +3
  • Conference Article

A calibration technique of 4-port vector network analyzers with a general 12-term error model

  • Sep 01, 2010
  • Quan Sun +4
  • Conference Article

High Frequency Transfer Characterization of a Three Phase Transformer Using Two-port Vector Network Analyzer

  • Jan 01, 2016
  • Kwangho Kim Kwangho Kim +1
  • Conference Article
  • Citations10

Using a single-ended TRL calibration pattern to de-embed coupled transmission lines

  • Aug 01, 2009
  • Jianmin Zhang +4
  • Research Article
  • Citations13

Measurement of Multi-Port S-Parameters using Four-Port Network Analyzer

  • Dec 31, 2013
  • JSTS:Journal of Semiconductor Technology and Science
  • Jongmin Kim +3
  • Conference Article

Network analyzer functionality simulator

  • Dec 02, 2004
  • P Malmlof
  • Research Article
  • Citations4

Extended Through-Short-Delay Technique for the Calibration of Vector Network Analyzers With Nonmating Waveguide Ports

  • Feb 01, 2010
  • IEEE Transactions on Microwave Theory and Techniques
  • O.A Peverini +4
  • Conference Article
  • Citations8

Full two-port on-wafer vector network analysis to 120 GHz using active probes

  • Jun 14, 1993
  • R Yu +5
  • Research Article
  • Citations1

Measuring Impedances of DC-biased Inductors by Using Vector Network Analyzers

  • Sep 06, 2019
  • International Journal of Electronics and Telecommunications
  • G Asmanis +3
  • Conference Article
  • Citations4

Second-order waveguide calibration of a one-port vector network analyzer

  • Jun 01, 2011
  • Rolf H Judaschke
  • Research Article
  • Citations4

2-MM WAVE VECTOR NETWORK ANALYZER UPON HIGH-ORDER IMPATT MULTIPLIERS

  • Feb 03, 2007
  • International Journal of Infrared and Millimeter Waves
  • Gennadiy P Ermak +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.