• Home
  • Search
  • Hilbert Transform Based FBP Algorithm for Fan-Beam CT Full and Partial Scans
  • Cite Icon31
  • https://doi.org/10.1109/tmi.2006.889705Copy DOI Icon

Hilbert Transform Based FBP Algorithm for Fan-Beam CT Full and Partial Scans

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper presents a new type of filtered backprojection (FBP) algorithm for fan-beam full- and partial-scans. The filtering is shift-invariant with respect to the angular variable. The backprojection does not include position-dependent weights through the Hilbert transform and the one-dimensional transformation between the fan- and parallel-beam coordinates. The strong symmetry of the filtered projections directly leads to an exact reconstruction for partial data. The use of the Hilbert transform avoids the approximation introduced by the nonuniform cutoff frequency required in the ramp filter-based FBP algorithm. Variance analysis indicates that the algorithm might lead to a better uniformity of resolution and noise in the reconstructed image. Numerical simulations are provided to evaluate the algorithm with noise-free and noisy projections. Our simulation results indicate that the algorithm does have better stability over the ramp-filter-based FBP and circular harmonic reconstruction algorithms. This may help improve the image quality for in place computed tomography scanners with single-row detectors.

Similar Papers
  • Research Article
  • Citations53

Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT.

  • Aug 01, 2015
  • American Journal of Roentgenology
  • Sana Boudabbous +5
  • Conference Article

Iterative FBP using new families of empirical filters

  • Oct 01, 2010
  • J Verhaeghe +1
  • Research Article
  • Citations146

FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection.

  • Feb 01, 2001
  • European Journal of Nuclear Medicine
  • Celso D Ramos +7
  • Conference Article

Measurements of axisymmetric temperature and H2O concentration distributions on a circular flat flame burner based on tunable diode laser absorption tomography

  • Oct 25, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Huihui Xia +9
  • Conference Article
  • Citations1

An experimental study on DBP and Hilbert filtering method for tomography reconstruction

  • Oct 01, 2010
  • Xiaozhen Lin +4
  • Research Article
  • Citations6

Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm

  • Jan 01, 2015
  • Journal of Computer Assisted Tomography
  • Hiromitsu Onishi +13
  • Research Article
  • Citations56

Noise‐resolution tradeoffs in x‐ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

  • Feb 22, 2011
  • Medical Physics
  • Joshua D Evans +4
  • Research Article

Special issue on medical imaging

  • Mar 01, 2014
  • Biomedical Engineering Letters
  • Dosik Hwang +1
  • Research Article
  • Citations185

Evaluation of Heavily Calcified Vessels with Coronary CT Angiography: Comparison of Iterative and Filtered Back Projection Image Reconstruction

  • Jun 21, 2011
  • Radiology
  • Matthias Renker +10
  • Research Article
  • Citations97

Filtered backprojection proton CT reconstruction along most likely paths

  • Feb 28, 2013
  • Medical Physics
  • Simon Rit +4
  • Conference Article
  • Citations1

Filtered back-projection reconstruction of photo-acoustic imaging based on an modified wavelet threshold function

  • Oct 19, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Zhong Ren +2
  • Research Article
  • Citations33

Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector

  • Apr 06, 2005
  • Physics in Medicine & Biology
  • Shuai Leng +3
  • Research Article
  • Citations22

Effects of reconstruction technique on the quality of abdominal CT angiography: A comparison between forward projected model-based iterative reconstruction solution (FIRST) and conventional reconstruction methods

  • Jul 20, 2018
  • European Journal of Radiology
  • Rongli Wu +9
  • Conference Article
  • Citations1

A nonlinear, image domain filtering method for PET images

  • Nov 09, 1997
  • T.H Farquhar +4
  • Research Article
  • Citations32

Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method.

  • Jun 24, 2014
  • Medical Physics
  • Yinghua Tao +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.