• Home
  • Search
  • Histomorphometric and removal torque analysis for TiO2hyphen;blasted titanium implants. An experimental study on dogs.
  • Cite Icon201
  • https://doi.org/10.1034/j.1600-0501.1992.030205.xCopy DOI Icon

Histomorphometric and removal torque analysis for TiO2hyphen;blasted titanium implants. An experimental study on dogs.

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The aim of the present study was to compare the anchorage of TiO2-blasted screw and cylindrical implants with conventionally used machine-produced screw and cylindrical implants inserted immediately in extraction sockets on dogs. 6 adult mongrel dogs had 3rd and 4th mandibular premolars extracted bilaterally and 24 commercial pure titanium implants were placed immediately in extraction sockets and covered with mucoperiosteum. Each dog had inserted 4 implants: 1 screw implant and 1 cylindrical implant blasted with titanium-dioxide-particles; 1 screw implant and 1 cylindrical implant with machine-produced (m.p.) surface (controls). After a healing period of 12 weeks, 16 implants from 4 animals were used for removal torque test, which demonstrated that significantly higher removal torque force was needed to unscrew the implants blasted with titanium-dioxide-particles, than the normal m.p. implants. The medians for the TiO2-blasted screw and cylindrical implants were > 150 Ncm and 105 Ncm, respectively, while the values for the m.p. implants were 60 Ncm and 35 Ncm, respectively. The SEM investigation demonstrated a high irregularity of the TiO2-blasted surface compared to the machined surface. The Ra and Rz values for surface roughness were higher for the TiO2-blasted implants than for the normal m.p. implants. Histomorphometrically, the arithmetic mean of the direct bone-implant contact fraction was 69%. There was no significant difference in direct bone-implant contact length fraction between TiO2-blasted implants and the control implants. The implants blasted with titanium-dioxide-particles in this study showed a better anchorage than implants with a machine-produced surface. The screw implants showed a better anchorage than the cylindrical implants.

Similar Papers
  • Research Article

Sinus lifting and varieties of subantral implantation in the use of screw intrabone implants

  • Mar 26, 2010
  • Journal of IMAB - Annual Proceeding (Scientific Papers)
  • Tihomir Georgiev
  • Research Article
  • Citations5

In Vivo Osteogenesis and In Vitro Streptococcus mutans Adherence: Porous-Surfaced Cylindrical Implants vs Rough-Surfaced Threaded Implants

  • Jan 01, 2013
  • The International Journal of Oral & Maxillofacial Implants
  • Renata Falchete Do Prado +9
  • Research Article
  • Citations17

Photo-activated implants: a triple-blinded, split-mouth, randomized controlled clinical trial on the resistance to removal torque at various healing intervals.

  • Sep 11, 2019
  • Clinical Oral Investigations
  • Algirdas Puisys +4
  • Research Article
  • Citations108

BMP stimulation of bone response adjacent to titanium implants in vivo.

  • Jun 01, 1999
  • Clinical Oral Implants Research
  • Kazuhisa Bessho +4
  • Research Article
  • Citations33

The biocompatibility (cell culture and histologic study) of hydroxy-apatite-coated implants created by ion beam dynamic mixing.

  • Jun 01, 1996
  • Clinical Oral Implants Research
  • Masao Yoshinari +2
  • Research Article
  • Citations4

A Comparative Pilot Study of Two Dental Implant Metals in a Pig Model

  • Dec 01, 2010
  • Implant Dentistry
  • Luigi F Rodella +7
  • Research Article
  • Citations161

The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching

  • May 15, 2003
  • Biomaterials
  • Sung-Am Cho
  • Research Article
  • Citations5

Assessment of Calcium Carbonate Coating on Osseointegration of Commercially Pure Titanium Implant by Torque Removal Test and Histomorphometric Analysis

  • Jan 01, 2017
  • Journal of Baghdad College of Dentistry
  • Mustafa S Mahmood +1
  • Research Article
  • Citations5

Immediate implant placement using injectable calcium phosphate hydraulic cement in dogs.

  • Mar 26, 2018
  • Journal of Applied Biomaterials & Functional Materials
  • P Van Landuyt +5
  • Research Article
  • Citations29

Influence of the local application of sodium alendronate gel on osseointegration of titanium implants

  • Jun 15, 2015
  • International Journal of Oral and Maxillofacial Surgery
  • M.B Guimarães +4
  • Research Article
  • Citations18

On the material dependency of peri-implant morphology and stability in healing bone

  • May 19, 2023
  • Bioactive Materials
  • Stefan Bruns +9
  • Research Article
  • Citations7

CaP Coating and Low-Level Laser Therapy to Stimulate Early Bone Formation and Improve Fixation of Rough Threaded Implants.

  • Dec 01, 2018
  • Implant dentistry
  • Renata Falchete Do Prado +8
  • Research Article
  • Citations18

Osseointegration of titanium implants with SLAffinity treatment: a histological and biomechanical study in miniature pigs.

  • Oct 28, 2015
  • Clinical Oral Investigations
  • Keng-Liang Ou +5
  • Research Article
  • Citations401

Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.

  • Dec 01, 1997
  • Clinical Oral Implants Research
  • Perry R Klokkevold +3
  • Research Article
  • Citations18

Comparison of ceramic and titanium implants in cats.

  • Jan 01, 1985
  • Acta Orthopaedica Scandinavica
  • Elin Barth +2
Cactus Communications logo