HTA corrosion resistant technology for free cooling

  • Mar 1, 2015
  • Yongzhan He +9 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

advent of the big data era, the rapid development of mobile internet, and the rising demand of cloud computing services require increasingly more compute capability from their data center. This compute increase will most likely come from higher rack and room power densities or even construction of new Internet data centers. But an increase in a data center's business-critical IT equipment (servers, hubs, routers, wiring patch panels, and other network appliances), not to mention the infrastructure needed to keep these devices alive and protected, encroaches on another IT goal: to reduce long-term energy usage. Large Internet Datacenters are looking at every possible way to reduce the cooling cost and improve efficiency. One of the emerging trends in the industry is to move to higher ambient datacenter operation and use air side economizers. However, these two trends can have significant implications for corrosion risk in data centers. prevailing practice surrounding the data centers has often been The colder, the However, some leading server manufacturers and data center efficiency experts share the opinion that data centers can run far hotter than they do today without sacrificing uptime, and with a huge savings in both cooling related costs and CO2 emissions. Why do we need to increase the temperatures? To cool data center requires huge refrigeration system which is energy hog and also cost of cooling infrastructure, maintenance cost and operation cost is heavy cost burden. This paper describes how HTA and Corrosion Resistance technology will reduce the refrigeration output and how this innovation will open up new direction in data centers. Note that, HTA is not to say that the higher the better. Before embracing HTA two keys points need to be addressed and understood. Firstly, server stability along with optimal temperature from data center perspective. Secondly, corrosion resistant technology. With Fresh air cooling the server has to bear with the seasons and diurnal variation of temperatures and these can be over 35 degree C, therefore to some extent, we have to say, HTA design is the premise of corrosion resistant design. In this paper, we present methods to realize precise HTA operation along with corrosive resistant technology. This is achieved through an orchestrated collaboration between the IT and cooling infrastructures.

Similar Papers
  • Conference Article
  • Citations4

Consideration for Running Data Center at High Temperatures and Using Free Air Cooling

  • Jul 06, 2015
  • Yongzhan He +7
  • Conference Article
  • Citations19

Qualitative Study of Cumulative Corrosion Damage of IT Equipment in a Data Center Utilizing Air-Side Economizer

  • Nov 11, 2016
  • Jimil M Shah +7
  • Conference Article

Swarm Intelligence Algorithms for Profit Maximization and Delay Minimization in Internet Data Centers

  • Mar 23, 2023
  • Haritha Paul +1
  • Research Article
  • Citations11

Review on Cooling System Energy Consumption in Internet Data Centers

  • Dec 01, 2016
  • International Journal of Air-Conditioning and Refrigeration
  • Kofi Owura Amoabeng +1
  • Research Article

Development of an energy model of a data center

  • Sep 07, 2025
  • Power engineering: research, equipment, technology
  • A K Yudin
  • Conference Article
  • Citations19

Online Server and Workload Management for Joint Optimization of Electricity Cost and Carbon Footprint Across Data Centers

  • May 01, 2014
  • Zahra Abbasi +2
  • PDF
  • Research Article
  • Citations16

Data Center Energy Evaluation Tool Development and Analysis of Power Usage Effectiveness with Different Economizer Types in Various Climate Zones

  • Jan 22, 2024
  • Buildings
  • Ji Hye Kim +2
  • Conference Article

Power Supply Cloudsim: An Extension of CloudSim for Modeling and Simulation of Power Supply Devices in Cloud Data Centers

  • Jul 08, 2022
  • Guisen Ye +4
  • Conference Article
  • Citations1

Operational Benefits of Real-Time Monitoring and Visualization in Data Centers

  • Jan 01, 2009
  • Tahir Cader +5
  • Conference Article
  • Citations2

Cost-Adaptive Load Sharing for Cloud Computing

  • Mar 01, 2018
  • Naor Zohar
  • Conference Article
  • Citations44

Multi-Scale Modeling of High Power Density Data Centers

  • Jan 01, 2003
  • Jeffrey D Rambo +1
  • Book Chapter

On the Construction of Internet Data Center in Colleges

  • Jan 01, 2013
  • Xiangya Tao +1
  • Research Article
  • Citations7

Data centre sustainability – Beyond energy efficiency

  • Jan 12, 2018
  • Building Services Engineering Research and Technology
  • Sophia Flucker +2
  • Conference Article
  • Citations6

Numerical Convective Heat Transfer Analysis of a Hybrid-Cooled Data Center Blade Server

  • May 01, 2019
  • Sara Battaglioli +2
  • Conference Article
  • Citations3

CFD Modeling of the Distribution of Airborne Particulate Contaminants Inside Data Center Hardware

  • Oct 27, 2020
  • PubMed Central
  • Satyam Saini +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.