Abstract

This study aims to assess setup errors for patients immobilized on different board inclinations and to evaluate the effect of body mass index (BMI) and breast size on positioning errors. Furthermore, the dosimetric impact of setup errors on target and organs at risk was measured using three different irradiation techniques (3D conformal radiotherapy, intensity modulated and volumetric modulated arc radiotherapy). A cohort of 40 breast cancer patients was split into two groups as a function of immobilization board inclination: 20 patients immobilized on 7.5° inclination (group A) and 20 on 0° (group B). Systematic and random errors were determined with weekly portal and tangential images. A strong correlation between BMI and both systematic (r=0.720) and random errors (r=0.752) was observed in posterior direction for group B, while the correlation between breast size and setup errors showed a moderate association under systematic errors for right (r=-0.507) and left (r=0.503) directions. The dosimetric impact of setup errors on target volume showed higher contribution from systematic than from random errors. Suboptimal coverage of target volume was more prominent in group A for all planning techniques (46.65Gy 3DCRT, 46.95Gy IMRT, 46.90Gy VMAT). Patients with high BMI could benefit from the inclined immobilization board with a higher frequency of image position verification. When comparing 3DCRT versus modulated techniques the ipsilateral lung is better spared with the latter, while the contralateral lung is more efficiently protected with conformal technique.

Similar Papers
  • PDF
  • Research Article
  • Citations49

Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

  • Dec 01, 2007
  • Radiation Oncology (London, England)
  • Tejpal Gupta +6
  • Research Article

A SINGLE INSTITUTIONAL AUDIT OF SETUP ERRORS FOR 3DCRT RECTAL CANCERS

  • Jan 29, 2020
  • Journal of Health and Translational Medicine
  • Wei Zhuen Chew +7
  • Research Article
  • Citations1

Impact of the Body-Mass Factors on Set-up Displacement in Patients Treated with Pelvic Irradiation for Gynecological Cancer with Daily On-Line Image Guidance

  • Mar 01, 2014
  • 放射治療與腫瘤學
  • Yo-Liang Lai +3
  • Research Article

SU‐GG‐J‐111: Evaluation of Reproducibility of Immobilization Device for Head‐And‐Neck Radiotherapy

  • Jun 01, 2010
  • Medical Physics
  • Y Chen +8
  • Research Article

Evaluation of set-up errors and estimation of set-up margin during external beam radiation therapy of prostate cancer using electronic portal imaging device (EPID)

  • Apr 22, 2021
  • Journal of Radiotherapy in Practice
  • Daryoush Khoramian +2
  • Research Article
  • Citations12

Macrosteatotic Allografts and Obese Recipients Have Nearly Equal Negative Impact on Liver Transplant Survival.

  • Jun 01, 2020
  • Transplantation
  • Patrick G Northup +4
  • Research Article

Analyzing of correlation between the setup error and the couch position in radiotherapy

  • Mar 15, 2016
  • Chinese Journal of Radiation Oncology
  • Guangbo Fu +5
  • Research Article
  • Citations23

Evaluation of set-up errors in head and neck radiotherapy using electronic portal imaging

  • Jan 02, 2013
  • Physica Medica
  • Bojan Strbac +1
  • Research Article
  • Citations1

Electronic portal imaging device in the real-time correction of setup error in intensity modulated radiation therapy for nasopharyngeal carcinoma

  • Sep 15, 2009
  • Chinese Journal of Radiation Oncology
  • Ci Pan +4
  • Research Article
  • Citations3

Comparative study of setup errors between new and reused thermoplastic masks in irradiated head and neck cancer patients

  • Aug 31, 2023
  • The ASEAN Journal of Radiology
  • Nipha Chumsuwan +3
  • Research Article

Investigating the Impact of Random and Systematic Errors on GPS Precise Point Positioning Ambiguity Resolution

  • Jun 30, 2014
  • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
  • Joong-Hee Han +2
  • Research Article
  • Citations17

Set-Up Errors, Organ Motion, Tumour Regression and its Implications on Internal Target Volume–Planning Target Volume During Cervical Cancer Radiotherapy: Results From a Prospective Study

  • Nov 02, 2021
  • Clinical Oncology
  • U Mahantshetty +9
  • Research Article
  • Citations1

Evaluation of Interfractional Setup Uncertainties and Calculation of Adequate CTV-PTV Margin for Head and Neck Radiotherapy using Electronic Portal Imaging Device.

  • Jan 01, 2023
  • Journal of biomedical physics & engineering
  • Elham Ahmadi +5
  • Research Article

SU‐F‐BRD‐07: Empirical Derivation of Site‐Specific Margin Formulas

  • May 29, 2014
  • Medical Physics
  • L Conroy +2
  • Research Article
  • Citations1

A service evaluation of on-line image-guided radiotherapy to lower extremity sarcoma: Investigating the workload implications of a 3 mm action level for image assessment and correction prior to delivery

  • Jan 06, 2018
  • Radiography
  • C Taylor +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.