Abstract

Despite significant progress, malapposed or overlapped stents are a complication that affects daily percutaneous coronary intervention (PCI) procedures. These malapposed stents affect blood flow and create a micro re-circulatory environment. These disturbances are often associated with a change in Wall Shear Stress (WSS), Time-averaged WSS (TAWSS), relative residence time (RRT) and oscillatory character of WSS and disrupt the delicate balance of vascular biology, providing a possible source of thrombosis and restenosis. In this study, 2D axisymmetric parametric computational fluid dynamics (CFD) simulations were performed to systematically analyze the hemodynamic effects of malapposition and stent overlap for two types of stents (drug-eluting stent and a bioresorbable stent). The results of the modeling are mainly analyzed using streamlines, TAWSS, oscillatory shear index (OSI) and RRT. The risks of restenosis and thrombus are evaluated according to commonly accepted thresholds for TAWSS and OSI. The small malapposition distances (MD) cause both low TAWSS and high OSI, which are potential adverse outcomes. The region of low OSI decrease with MD. Overlap configurations produce areas with low WSS and high OSI. The affected lengths are relatively insensitive to the overlap distance. The effects of strut size are even more sensitive and adverse for overlap configurations compared to a well-applied stent.

Loading PDF

Similar Papers
  • Research Article
  • Citations14

Numerical simulation in the abdominal aorta and the visceral arteries with or without stenosis based on 2D PCMRI.

  • Jan 18, 2022
  • International Journal for Numerical Methods in Biomedical Engineering
  • Chen Peng +8
  • Research Article

P3588The synergistic effect of NIRS-detected lipid-rich plaque and 5 different multidirectional wall shear stress metrics on human coronary plaque growth

  • Oct 01, 2019
  • European Heart Journal
  • E M J Hartman +6
  • PDF
  • Research Article
  • Citations30

On the Potential Self-Amplification of Aneurysms Due to Tissue Degradation and Blood Flow Revealed From FSI Simulations.

  • Dec 10, 2021
  • Frontiers in Physiology
  • Haifeng Wang +4
  • Research Article
  • Citations12

Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts

  • Mar 19, 2015
  • Journal of Biomechanics
  • T Meirson +2
  • Research Article
  • Citations15

Newly Identified Hemodynamic Parameter to Predict Thin-Walled Regions of Unruptured Cerebral Aneurysms Using Computational Fluid Dynamics Analysis

  • Jun 01, 2021
  • World Neurosurgery
  • Hidehito Kimura +8
  • Research Article
  • Citations65

Impact of bifurcation angle and other anatomical characteristics on blood flow – A computational study of non-stented and stented coronary arteries

  • Mar 29, 2016
  • Journal of Biomechanics
  • Susann Beier +7
  • Research Article

Hemodynamic characteristics of type I Endoleak and intra-prosthetic thrombus following endovascular aneurysm repair: A computational fluid dynamics study.

  • May 01, 2026
  • Computer methods and programs in biomedicine
  • Jun Wen +6
  • Research Article
  • Citations1

A hemodynamic study of blood flow models on various stent graft configurations during aorto-iliac reconstruction.

  • Jun 25, 2024
  • Clinical Hemorheology and Microcirculation
  • Konstantinos Tzirakis +2
  • Research Article
  • Citations14

Numerical analysis of hemodynamic parameters in stenosed arteries under pulsatile flow conditions

  • Sep 29, 2023
  • Medicine in Novel Technology and Devices
  • Priyambada Praharaj +7
  • Research Article
  • Citations6

A multi-modal computational fluid dynamics model of left atrial fibrillation haemodynamics validated with 4D flow MRI.

  • Jan 19, 2025
  • Biomechanics and modeling in mechanobiology
  • Louis Parker +9
  • Research Article

Integrated Assessment of Wall Shear Stress-Related Hemodynamic Parameters in Abdominal Aortic Aneurysms: A Retrospective Cross-Sectional Study onRuptured Cases.

  • Mar 01, 2026
  • International journal for numerical methods in biomedical engineering
  • Onur Mutlu +7
  • Research Article
  • Citations4

De Novo Aneurysm Formation After Wingspan Stenting of Intracranial Carotid Stenosis: Computational Hemodynamic Analysis

  • Mar 13, 2019
  • World Neurosurgery
  • Feng Wang +3
  • Research Article

Patient-specific fluid-structure interaction modeling of cerebral aneurysm: influence of wall compliance, tissue prestress, and blood rheology.

  • May 01, 2026
  • Computer methods and programs in biomedicine
  • Amit Raj +2
  • PDF
  • Research Article
  • Citations35

Baseline local hemodynamics as predictor of lumen remodeling at 1-year follow-up in stented superficial femoral arteries

  • Jan 15, 2021
  • Scientific Reports
  • Monika Colombo +8
  • Research Article
  • Citations8

MRI and Blood Flow in Human Arteries: Are There Any Adverse Effects?

  • Jan 28, 2019
  • Cardiovascular Engineering and Technology
  • K Gayathri +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.