• Home
  • Search
  • Improved high-frequency high frame rate duplex ultrasound linear array imaging system
  • Cite Icon3
  • https://doi.org/10.1109/ultsym.2008.0424Copy DOI Icon

Improved high-frequency high frame rate duplex ultrasound linear array imaging system

  • Nov 1, 2008
  • Lequan Zhang +6 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In this paper, we report recent progress that has been made in the development of a high frame rate duplex HF ultrasound system with both B-scan imaging and Doppler flow measurements. A 32-channel HF analog beamformer module with transmitting focusing and dynamic focusing on reception was implemented. High-speed timing circuits were used to achieve high imaging frame rate by reducing the acquisition overhead. Therefore, the frame rate of the system relies only on the field of view. The system also included a 64-channel analog front-end pulser/receiver, a HF pulsed-wave (PW) Doppler module, a PC with a 200MS/s 14-bit PCI A/D card and real-time Labview software for data acquisition and image display. A wire phantom used to evaluate the resolution of the system. High frame rate B-scan images of mouse hearts have been obtained, as well as the PW Doppler blood flow velocity profiles at the specified location. The system is able to acquire real-time B-mode images at a rate greater than 400 frames per second in a 4.8 × 13 mm field of view. In vivo mouse experiment results show a promising future of this system in small animal research. The system will be expanded to support future arrays with more elements.

Similar Papers
  • Conference Article
  • Citations1

Research on high frame rate scene projection method based on digital micromirror device (DMD)

  • Mar 12, 2020
  • Song Jian +6
  • Research Article
  • Citations9

A Comparison of Visual Recognition of the Laryngopharyngeal Structures Between High and Standard Frame Rate Videos of the Fiberoptic Endoscopic Evaluation of Swallowing.

  • Apr 29, 2017
  • Dysphagia
  • Mehran Alizadeh Aghdam +5
  • Research Article

Principle study on exposure technique for double pulse high speed imaging based on direct control of CCD driving electrodes

  • Jun 24, 2020
  • High Power Laser and Particle Beams
  • Xiaoguo Jiang +7
  • Conference Article
  • Citations8

Physical evaluation of a high-frame-rate extended dynamic range flat panel detector for real-time cone beam computed tomography applications

  • Apr 20, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Sarah J Boyce +2
  • Conference Article

Temporal and Resolution Layering in Advanced Television

  • Feb 01, 1996
  • Gary Demos
  • Research Article

Digitized reality: Effects of high frame rate on visual perception

  • Jun 03, 2016
  • Open Access CRIS of the University of Bern
  • Miriam Laura Loertscher +1
  • Book Chapter
  • Citations9

Frame Rate and Perceptual Quality for HD Video

  • Jan 01, 2015
  • Yutao Liu +3
  • Conference Article
  • Citations4

A Projection-Based Multi-view Time-multiplexed Autostereoscopic 3D Display System

  • Jul 05, 2006
  • Ying Zhang +1
  • Conference Article
  • Citations18

The Effects of Frame Rate Variation on Game Player Quality of Experience

  • Apr 19, 2023
  • Shengmei Liu +3
  • Conference Article
  • Citations8

Evaluating the effects of image persistence on dynamic target acquisition in low frame rate virtual environments

  • Mar 01, 2016
  • David J Zielinski +5
  • Conference Article
  • Citations12

Dual-sensor camera for acquiring image sequences with different spatio-temporal resolution

  • Oct 11, 2016
  • H Nagahara +5
  • Research Article
  • Citations3

The effect of frame rates on knee kinetics during landing and cutting

  • Jan 23, 2013
  • International Journal of Precision Engineering and Manufacturing
  • Seunghoon Lee +1
  • Conference Article

Contrast-resolution Evaluation of Fourier Based High Frame Rate Imaging

  • Dec 10, 2020
  • Zhaohui Wang
  • Research Article
  • Citations12

Effects of Phase Aberration and Noise on Extended High Frame Rate Imaging

  • Apr 01, 2007
  • Ultrasonic Imaging
  • Jing Wang +1
  • Research Article
  • Citations77

Optimized Plane Wave Imaging for Fast and High-Quality Ultrasound Imaging.

  • Nov 01, 2016
  • IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
  • Jonas Jensen +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.