Abstract

Noninvasive assessment of diastolic dysfunction relies on multiple echocardiographic indicators, including measurements from both standard B-mode images and Doppler, obtained at various cardiac locations such as the mitral annulus, tricuspid annulus, left ventricle, and left atrium. The diagnostic process is complex and subject to interobserver variability, making accurate and rapid evaluation challenging. Automated semantic segmentation of key cardiac structures, such as the left atrium, left ventricle, and mitral valve annulus, offers a potential solution by capturing temporal changes throughout the cardiac cycle. This study aims to improve the accuracy of segmenting the left atrium, left ventricle, and mitral valve annulus in echocardiographic images and to leverage the resulting temporal segmentation features for more reliable identification of diastolic dysfunction. This study presents Diff-TransUNet, a novel segmentation model incorporating a noise-robust Differential Transformer module. Evaluations on private (1137 training images, 135 validation images, and 88 test images), CAMUS (1400 training images, 200 validation images, and 200 test images), and EchoNet-Dynamic (5000 training images, 2546 validation images, and 2528 test images) datasets demonstrate improved performance over state-of-the-art methods, assessed by Dice coefficient (Dice), Intersection-over-Union (IoU), and 95th percentile Hausdorff Distance (HD95) metrics. Statistical analysis was performed to compare Diff-TransUNet with baseline methods across evaluation metrics. To control for errors arising from multiple comparisons, p-values were adjusted using the Benjamini-Hochberg false discovery rate (FDR) correction. Statistical significance was assessed at a 95% confidence level. In addition to p-values, Cohen's d effect size was computed to quantify the practical significance of performance differences. The proposed Diff-TransUNet achieved a Dice of 87.49%, IoU of 79.07%, and HD95 of 1.48 on the private dataset. Compared with state-of-the-art models, Dice improved by 1.35%-4.30% (p<0.05, Cohen's d=0.32-0.90), IoU by 1.97%-5.67% (p<0.05, Cohen's d=0.37-1.03), and HD95 by 0.16-0.83 (p<0.05, Cohen's d=0.21-0.90). On the CAMUS dataset, the model achieved a Dice of 88.74%, IoU of 80.58%, and HD95 of 2.83, showing improvements of 1.07%-4.96% (p<0.05, Cohen's d=0.18-0.63) in Dice, 1.55%-6.89% (p<0.05, Cohen's d=0.19-0.71) in IoU, and 0.41-2.85 (p<0.05, Cohen's d=0.12-0.46) in HD95 compared to advanced models. On the EchoNet-Dynamic dataset, the model obtained a Dice of 92.25%, IoU of 85.87%, and HD95 of 1.65, outperforming other methods by 0.42%-2.00% (p<0.05, Cohen's d=0.10-0.40) in Dice, 0.69%-3.21% (p<0.05, Cohen's d=0.10-0.43) in IoU, and 0.21-1.12 (p<0.05, Cohen's d=0.09-0.34) in HD95. Furthermore, by extracting volumetric segmentation features, the proposed method achieved an accuracy of 88.95% (95 % CI 87.15% to 90.08%) in identifying diastolic dysfunction. The proposed Diff-TransUNet model achieves significant improvements in ultrasound segmentation. Features extracted from the left ventricle, left atrium, and mitral annulus segmented by Diff-TransUNet can be effectively used for the identification of diastolic dysfunction.

Similar Papers
  • Research Article
  • Citations5

Presystolic mitral annular septal–lateral shortening is independent from left atrial and left ventricular contraction during acute volume depletion☆☆☆

  • Apr 25, 2009
  • European Journal of Cardio-Thoracic Surgery
  • Wolfgang Bothe +6
  • Abstract

Mitral annular electrogram morphology - a balanced signal does not identify the anatomical annulus

  • May 24, 2023
  • Europace
  • Sdoctor Williams +12
  • Research Article
  • Citations11

Values for Mitral Valve Annulus Dimensions in Normals and Patients with Mitral Regurgitation.

  • Nov 01, 1997
  • Echocardiography (Mount Kisco, N.Y.)
  • Marie-Christine Herregods +4
  • Research Article
  • Citations46

Circumferential suture of the mitral annulus for correction of mitral regurgitation in dogs.

  • May 01, 1998
  • Veterinary Surgery
  • James W Buchanan +1
  • Research Article
  • Citations1

Dynamics of the Mitral Valve Annulus in Hypertrophic Obstructive Cardiomyopathy Patients Undergoing Septal Myectomy: Insights From 3D Transesophageal Echocardiography.

  • Oct 01, 2025
  • Echocardiography (Mount Kisco, N.Y.)
  • Mahmoud Shaaban +6
  • Research Article
  • Citations14

Histopathology of Monopolar Transcatheter Radiofrequency Ablation at the Mitral Valve Annulus

  • Nov 01, 1991
  • Pacing and Clinical Electrophysiology
  • Michael C Chin +5
  • Research Article
  • Citations21

Evaluation of the hemodynamic relationship between the left atrium and left ventricle during atrial systole by pulsed tissue Doppler imaging in patients with left heart failure.

  • Jan 01, 1999
  • Japanese Circulation Journal
  • Miho Abe +8
  • Research Article
  • Citations8

Mitral annulus after mitral repair: geometry and dynamics.

  • Jul 01, 2002
  • ASAIO journal (American Society for Artificial Internal Organs : 1992)
  • Takeshi Komoda +5
  • Research Article
  • Citations468

American society of echocardiography guidelines and standards for performance of the fetal echocardiogram

  • Jul 01, 2004
  • Journal of the American Society of Echocardiography
  • Jack Rychik +6
  • Research Article
  • Citations48

Stepwise linear approach to catheter ablation of atrial fibrillation

  • Aug 11, 2007
  • Heart Rhythm
  • Yan Yao +9
  • Research Article
  • Citations21

A simplified method for determining regurgitant fraction by Doppler echocardiography in patients with aortic regurtitation

  • Oct 01, 1994
  • Journal of the American College of Cardiology
  • Gong-Yuan Xie +3
  • Research Article
  • Citations12

DYNAMIC CHANGE IN LEFT VENTRICULAR (LV) BASE WITH OR WITHOUT A RIGID MITRAL VALVE PROSTHESIS

  • Mar 01, 1997
  • ASAIO Journal
  • T Komoda +9
  • Research Article
  • Citations1

Find me if you can: lessons learned using the novel cartofinder algorithm in a routine workflow for catheter ablation of atrial fibrillation

  • May 24, 2021
  • EP Europace
  • C Sohns +10
  • Research Article
  • Citations53

Guidelines for Performing a Comprehensive Epicardial Echocardiography Examination: Recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists

  • Jul 01, 2007
  • Anesthesia &amp; Analgesia
  • Scott T Reeves +6
  • Peer Review Report
  • Citations19

Author response: Early patterning and specification of cardiac progenitors in gastrulating mesoderm

  • Sep 24, 2014
  • W Patrick Devine +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.