Improvements of 3-D image quality in integral display by reducing distortion errors

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

An integral three-dimensional (3-D) system based on the principle of integral photography can display natural 3-D images. We studied ways of improving the resolution and viewing angle of 3-D images by using extremely highresolution (EHR) video in an integral 3-D video system. One of the problems with the EHR projection-type integral 3-D system is that positional errors appear between the elemental image and the elemental lens when there is geometric distortion in the projected image. We analyzed the relationships between the geometric distortion in the elemental images caused by the projection lens and the spatial distortion of the reconstructed 3-D image. As a result, we clarified that 3-D images reconstructed far from the lens array were greatly affected by the distortion of the elemental images, and that the 3-D images were significantly distorted in the depth direction at the corners of the displayed images. Moreover, we developed a video signal processor that electrically compensated the distortion in the elemental images for an EHR projection-type integral 3-D system. Therefore, the distortion in the displayed 3-D image was removed, and the viewing angle of the 3-D image was expanded to nearly double that obtained with the previous prototype system.

Similar Papers
  • Conference Article
  • Citations2

Integral imaging system using an array of planar mirrors

  • Feb 15, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jun Arai +2
  • Conference Article
  • Citations14

Human perception of geometric distortions in images

  • Jun 22, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Iwan Setyawan +1
  • Research Article
  • Citations42

Geometrical effects of positional errors in integral photography.

  • Jun 01, 2004
  • Journal of the Optical Society of America A
  • Jun Arai +3
  • Research Article
  • Citations2

Novel diffraction limit implied geometric lens imaging model based on a finite number of pixels for integral imaging display

  • Mar 25, 2023
  • Optics and Lasers in Engineering
  • Yong Seok Hwang +2
  • Research Article
  • Citations38

Diffusion-Weighted Imaging of the Prostate: Image Quality and Geometric Distortion of Readout-Segmented Versus Selective-Excitation Accelerated Acquisitions.

  • Nov 01, 2015
  • Investigative Radiology
  • Borna K Barth +4
  • Conference Article
  • Citations1

Integral imaging using pupil modulation and depth-control processing

  • Feb 04, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jun Arai +4
  • Research Article
  • Citations48

Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate.

  • Apr 01, 2018
  • Investigative Radiology
  • Daniel Stocker +6
  • Research Article
  • Citations4

Evaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T

  • Sep 04, 2023
  • Egyptian Journal of Radiology and Nuclear Medicine
  • Eric Naab Manson +3
  • Research Article

Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences.

  • Dec 05, 2024
  • Dento maxillo facial radiology
  • Tong Su +11
  • Book Chapter
  • Citations30

Exploiting Vector Fields for Geometric Rectification of Distorted Document Images

  • Jan 01, 2018
  • Gaofeng Meng +4
  • Conference Article
  • Citations53

<title>Three-dimensional display system based on computer-generated integral photography</title>

  • Jun 22, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Sung-Wook Min +3
  • Research Article
  • Citations69

DIBR-synthesized image quality assessment based on morphological multi-scale approach

  • Jul 26, 2016
  • EURASIP Journal on Image and Video Processing
  • Dragana Sandić-Stanković +2
  • Research Article

SU‐E‐J‐227: Evaluation of Residual Geometric Distortion in MRI for Treatment Planning

  • Jun 01, 2015
  • Medical Physics
  • J Wang +5
  • Research Article
  • Citations54

Multi-viewer tracking integral imaging system and its viewing zone analysis

  • Sep 22, 2009
  • Optics Express
  • Gilbae Park +6
  • Research Article
  • Citations30

Retrospective distortion correction of diffusion tensor imaging data by semi-elastic image fusion – Evaluation by means of anatomical landmarks

  • Jun 10, 2019
  • Clinical Neurology and Neurosurgery
  • Julia Gerhardt +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.