• Home
  • Search
  • Improving Calibration of Photon Counting Detector CT Using Redundant Sampling
  • https://doi.org/10.1109/nss/mic/rtsd57106.2025.11286727Copy DOI Icon

Improving Calibration of Photon Counting Detector CT Using Redundant Sampling

  • Nov 1, 2025
  • Scott S Hsieh +3 more
Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Ring artifacts are a major obstacle that prevent the easy adoption of photon counting detectors (PCDs) into next-generation CT scanners. PCDs use a direct conversion semiconductor rather than an indirect conversion scintillator, but the stability of common direct conversion semiconductors (CdTe, CZT) remains limited. Small changes in sensitivity between neighboring pixels are amplified in CT reconstruction and result in ring artifacts in PCD CT images. To reduce these artifacts, we propose that pixels be dynamically autocalibrated to each other during the scan. This is done by measuring line integrals with two neighboring detector pixels and building a model of the differences between these two pixels. This can be done practically using flying focal spot, which minimizes the temporal offset between the two datasets. In this work, we demonstrate the proof of principle with a detector shift. The two resulting sinograms are used in an optimization problem that estimates gain factors on a per-pixel level. Preliminary results in a chicken thigh specimen and resolution phantom show strong reductions in ring artifact by about 75%.

Similar Papers
  • Research Article
  • Citations2

Feature shared multi-decoder network using complementary learning for Photon counting CT ring artifact suppression.

  • Apr 25, 2024
  • Journal of X-ray science and technology
  • Wei Cui +7
  • Research Article
  • Citations4

DuDo-RAC: Dual-domain optimization for ring artifact correction in photon counting CT.

  • May 01, 2025
  • Computer methods and programs in biomedicine
  • Shengqi Kan +6
  • Research Article
  • Citations2

GDP-Net: Global Dependency-Enhanced Dual-Domain Parallel Network for Ring Artifact Removal.

  • Jun 01, 2025
  • IEEE transactions on medical imaging
  • Yikun Zhang +11
  • Research Article
  • Citations23

Ring-artifacts removal for photon-counting CT.

  • Aug 11, 2020
  • Optics Express
  • Kang An +4
  • Research Article
  • Citations3

TH‐E‐330A‐03: Reduction of Ring Artifacts in Cone Beam CT: Artifact Detection and Correction for Flat Panel Imagers

  • Jun 01, 2006
  • Medical Physics
  • M Altunbas +2
  • Research Article
  • Citations14

Removing ring artefacts in CT images via unidirectional relative variation model

  • Oct 01, 2016
  • Electronics Letters
  • Qirun Huo +2
  • Conference Article
  • Citations9

A count rate-dependent method for spectral distortion correction in photon counting CT

  • Jan 01, 2018
  • Medical Imaging 2018: Physics of Medical Imaging
  • Jannis Dickmann +6
  • Research Article
  • Citations5

Assessment of material identification and quantification in the presence of metals using spectral photon counting CT.

  • Sep 13, 2024
  • PloS one
  • Briya Tariq +8
  • Book Chapter

Ring artifacts on Ethos HyperSight kV cone beam CT (kV- CBCT) scans: a comparative study using patient images, QA phantoms and an anthropomorphic phantom supporting on-couch adaptive radiotherapy

  • Jan 01, 2025
  • Research Article
  • Citations7

Combine TV-L1 model with guided image filtering for wide and faint ring artifacts correction of in-line x-ray phase contrast computed tomography.

  • Feb 23, 2018
  • Journal of X-Ray Science and Technology
  • Dongjiang Ji +4
  • Research Article
  • Citations8

Photon-Counting Detector CT With Denoising for Imaging of the Osseous Pelvis at Low Radiation Doses: A Phantom Study.

  • Nov 22, 2023
  • AJR. American journal of roentgenology
  • Roy P Marcus +5
  • Research Article
  • Citations24

Estimation of Basis Line-Integrals in a Spectral Distortion-Modeled Photon Counting Detector Using Low-Rank Approximation-Based X-Ray Transmittance Modeling: K-Edge Imaging Application.

  • Aug 29, 2017
  • IEEE Transactions on Medical Imaging
  • Okkyun Lee +3
  • Research Article
  • Citations8

3D-T2W-TSE radiotherapy treatment planning MRI using compressed sensing acceleration for prostate cancer: Image quality and delineation value.

  • Jan 24, 2022
  • Asia-Pacific Journal of Clinical Oncology
  • Oi Lei Wong +9
  • Conference Article
  • Citations4

Metal Artifact Correction Algorithm for CT

  • Oct 01, 2013
  • Debashish Pal +2
  • Research Article
  • Citations2

Reliability and benefits of single-energy projection-based metallic artifact reduction (SEMAR) in the different orthopedic hardware for the hip.

  • Mar 26, 2022
  • Skeletal Radiology
  • Yu-Hua Chen +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.