• Home
  • Search
  • Increasing the darkfield contrast-to-noise ratio using a deconvolution-based information retrieval algorithm in X-ray grating-based phase-contrast imaging
  • Cite Icon19
  • https://doi.org/10.1364/oe.21.018011Copy DOI Icon

Increasing the darkfield contrast-to-noise ratio using a deconvolution-based information retrieval algorithm in X-ray grating-based phase-contrast imaging

Show More
  • Abstract
  • Highlights & Summary
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A novel information retrieval algorithm for X-ray grating-based phase-contrast imaging based on the deconvolution of the object and the reference phase stepping curve (PSC) as proposed by Modregger et al. was investigated in this paper. We applied the method for the first time on data obtained with a polychromatic spectrum and compared the results to those, received by applying the commonly used method, based on a Fourier analysis. We confirmed the expectation, that both methods deliver the same results for the absorption and the differential phase image. For the darkfield image, a mean contrast-to-noise ratio (CNR) increase by a factor of 1.17 using the new method was found. Furthermore, the dose saving potential was estimated for the deconvolution method experimentally. It is found, that for the conventional method a dose which is higher by a factor of 1.66 is needed to obtain a similar CNR value compared to the novel method. A further analysis of the data revealed, that the improvement in CNR and dose efficiency is due to the superior background noise properties of the deconvolution method, but at the cost of comparability between measurements at different applied dose values, as the mean value becomes dependent on the photon statistics used.

Similar Papers
  • Research Article
  • Citations10

Lateral geniculate nucleus volumetry at 3T and 7T: Four different optimized magnetic-resonance-imaging sequences evaluated against a 7T reference acquisition

  • Oct 17, 2018
  • NeuroImage
  • Njoud Aldusary +12
  • Research Article
  • Citations124

Susceptibility weighted imaging with multiple echoes

  • Dec 20, 2009
  • Journal of Magnetic Resonance Imaging
  • Christian Denk +1
  • Research Article
  • Citations91

Noise in x‐ray grating‐based phase‐contrast imaging

  • Jun 23, 2011
  • Medical Physics
  • Thomas Weber +7
  • Research Article
  • Citations34

Evaluation of gadobutrol, a macrocyclic, nonionic gadolinium chelate in a brain glioma model: Comparison with gadoterate meglumine and gadopentetate dimeglumine at 1.5 T, combined with an assessment of field strength dependence, specifically 1.5 versus 3 T

  • Feb 25, 2010
  • Journal of Magnetic Resonance Imaging
  • Ulrike I Attenberger +5
  • Research Article
  • Citations131

Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT1

  • Apr 10, 2015
  • Radiology
  • Shuai Leng +3
  • PDF
  • Research Article
  • Citations1

A Spatial Compounding Method for Non-Delayed Sequential Beamforming

  • Oct 02, 2021
  • Applied Sciences
  • Siyi Liang +1
  • Research Article
  • Citations1

Quantitative analysis of deep learning reconstruction in CT angiography: Enhancing CNR and reducing dose.

  • Dec 18, 2024
  • Journal of X-ray science and technology
  • Chang-Lae Lee
  • Research Article

A modular deep learning pipeline for enhanced plane-wave beamforming and B-mode image quality.

  • Jul 23, 2025
  • Medical physics
  • Hamza Hadri +2
  • Research Article
  • Citations14

Application of X-ray grating interferometry for the imaging of joint structures

  • Oct 01, 2013
  • Anatomical Science International
  • Masabumi Nagashima +5
  • Research Article
  • Citations23

Comparison of breast specific gamma imaging and molecular breast tomosynthesis in breast cancer detection: Evaluation in phantoms.

  • Jun 19, 2015
  • Medical physics
  • Zongyi Gong +1
  • Research Article
  • Citations1

Optical coherence tomography angiography integrating differential phase and intensity images for in vivo imaging of a mouse retina.

  • Jun 23, 2025
  • Optics letters
  • Fuwang Wu +8
  • Research Article
  • Citations431

The Generalized Contrast-to-Noise Ratio: A Formal Definition for Lesion Detectability.

  • Nov 29, 2019
  • IEEE transactions on ultrasonics, ferroelectrics, and frequency control
  • Alfonso Rodriguez-Molares +6
  • Research Article
  • Citations1

An Investigation of PET Scan Parameters for Lesion Detection With GE VISTA Small-Animal Scanner Using Monte Carlo Simulation and Multivariate Analysis

  • Apr 01, 2013
  • IEEE Transactions on Nuclear Science
  • Tung-Hsin Wu +2
  • Research Article
  • Citations10

Assessing the deep learning based image quality enhancements for the BGO based GE omni legend PET/CT

  • Oct 16, 2024
  • EJNMMI Physics
  • Meysam Dadgar +4
  • Research Article
  • Citations2

Adaptive dual-energy algorithm based on pre-calibrated weighting factors for chest radiography

  • Apr 21, 2022
  • Physics in Medicine & Biology
  • Ivan Romadanov +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.