• Home
  • Search
  • Investigation on reference value error in multivariate calibration
  • https://doi.org/10.1117/12.806627Copy DOI Icon

Investigation on reference value error in multivariate calibration

  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Near infrared spectral analysis is a kind of indirect measuring technology, that is, calibration model is established by using sample spectra and the reference value of the interested concentration, and then predict the interested concentration of the unknown sample by using its spectrum and calibration model. Generally, the quality of calibration model is evaluated by the deviation between the predicted value and the reference value of the measured concentration. Reference value measurement error of the calibration set samples and model error are the main error source of multivariate calibration. When there was reference value measurement error, the regression model would cause great prediction deviation. However in practical application, apparent prediction error caused by reference value measurement error is always considered as the faultiness of calibration model. So it is falsely regarded that the prediction error of multivariate calibration model would be greater than that of reference method. In this paper, effect of reference value measurement error on prediction error was analyzed, and the relationship among apparent prediction error, actual prediction error and reference value measurement error was discussed. At the same time, the applicability and rationality of a computation formula was also discussed, which could estimate the true prediction error in a more precise way. It was proved that the prediction accuracy of an excellent calibration model was greater than that of the reference method by analyzing the reference value measurement error. An experiment of glucose aqueous solution samples was given in this paper. In this example, the effect of reference value measurement error on the prediction error of multivariate calibration model was investigated, and the estimating formula of the corrected prediction error was evaluated. The conclusion could be universally applied to not only multivariate calibration MLR, PCR, PLS and so on, but also in much more complex samples.

Similar Papers
  • Research Article
  • Citations11

Leveraging multiple linear regression for wavelength selection

  • Jul 27, 2017
  • Chemometrics and Intelligent Laboratory Systems
  • Tony Lemos +1
  • Single Report
  • Citations1

Comparison of Alternative Methods of Measuring ASVAB Test Composite Fairness

  • Jul 01, 2004
  • Joseph Zeidner +3
  • Research Article
  • Citations1

Mean Squared Prediction Error Reduction with Instrumental Variables

  • Jul 31, 2016
  • SSRN Electronic Journal
  • Antonis Michis
  • Research Article
  • Citations8

Evaluating the validity of spectral calibration models for quantitative analysis following signal preprocessing

  • Sep 04, 2012
  • Analytical and Bioanalytical Chemistry
  • Da Chen +1
  • Book Chapter

Application of Wavelet Component Selection and Orthogonal Signal Correction in the Multivariate Calibration by Near-Infrared Spectroscopy

  • Jan 01, 2011
  • Dan Peng +3
  • Preprint Article

Incorporating observational errors in multivariate hydrologic model calibration: the value in known unknowns

  • Mar 04, 2021
  • Lucy Marshall
  • Research Article
  • Citations2

Calibration model fusion

  • May 14, 2021
  • Journal of Chemometrics
  • Helene Fog Froriep Halberg +3
  • Research Article
  • Citations68

Determination of free amino acid content in Radix Pseudostellariae using near infrared (NIR) spectroscopy and different multivariate calibrations

  • Jun 27, 2009
  • Journal of Pharmaceutical and Biomedical Analysis
  • Hao Lin +3
  • PDF
  • Research Article
  • Citations15

Multivariate approach in voltammetric identification and simultaneous determination of eugenol, carvacrol, and thymol on boron-doped diamond electrode

  • May 10, 2019
  • Monatshefte für Chemie - Chemical Monthly
  • Mateusz Kowalcze +1
  • PDF
  • Research Article
  • Citations1

Modern Metaheuristic with Multi-Objective Formulation for the Variable Selection Problem

  • Nov 01, 2017
  • Journal of Computer Science
  • Lauro Cassio Martins De Paula +4
  • Research Article
  • Citations2

Linear transformations of multivariate calibration models in near infrared spectroscopy: A comparative study

  • Jul 30, 2017
  • Journal of Near Infrared Spectroscopy
  • Joseph Dubrovkin
  • Research Article
  • Citations50

Multivariate calibration standardization across instruments for the determination of glucose by Fourier transform near-infrared spectrometry.

  • Sep 20, 2003
  • Analytical Chemistry
  • Lin Zhang +2
  • Supplementary Content
  • Citations5

The influence of vegetation cover on the spectroscopic estimation of soil properties

  • Jan 01, 2009
  • Zurich Open Repository and Archive (University of Zurich)
  • Harm Bartholomeus
  • Research Article
  • Citations6

Monitoring of multivariate calibration models in the absence of new reference values: The regression case

  • Jun 08, 2023
  • Chemometrics and Intelligent Laboratory Systems
  • Valeria Fonseca Diaz +4
  • PDF
  • Research Article
  • Citations23

Ripening assessment of ‘Ortanique’ (Citrus reticulata Blanco x Citrus sinensis (L) Osbeck) on tree by SW-NIR reflectance spectroscopy-based calibration models

  • Oct 06, 2021
  • Postharvest Biology and Technology
  • Rosa Pires +9
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.