• Home
  • Search
  • Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections
  • Cite Icon9
  • https://doi.org/10.1088/0031-9155/43/4/010Copy DOI Icon

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam projections

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In single photon emission computed tomography (SPECT), a varying-focal-length cone-beam collimator can be used to reduce the truncation problem and to maintain sensitivity when imaging the organ of interest. The collimator is constructed so that the collimator holes focus to a circular symmetric, spatially varying, focal point function. The focal length increases radially from the shortest focal length at the centre to the longest focal length at the periphery of the collimator. This paper describes a 3D backprojection-filtering (BF) algorithm for this varying-focal-length cone-beam geometry. The proposed algorithm is compared to an iterative ML-EM (maximum likelihood-expectation maximization) algorithm. The 3D Hoffman brain phantom and Defrise phantom are used in computer simulations. Since the maximum tilt angle of the projection rays is small for most realistic imaging geometries, the proposed algorithm provides a good approximation. When a circular orbit is used, the BF algorithm gives an exact reconstruction of the central slice.

Similar Papers
  • Research Article
  • Citations9

Filtered Backprojection Algorithm Can Outperform Iterative Maximum Likelihood Expectation-Maximization Algorithm.

  • May 12, 2012
  • International Journal of Imaging Systems and Technology
  • Gengsheng L Zeng
  • Research Article
  • Citations53

Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT.

  • Aug 01, 2015
  • American Journal of Roentgenology
  • Sana Boudabbous +5
  • Research Article
  • Citations2

Information analysis for 3D SPECT imaging of radionuclide distributions in attenuating objects

  • Aug 01, 1994
  • IEEE Transactions on Nuclear Science
  • Huili Wang +2
  • Research Article
  • Citations46

Improvement of Image Quality at Low–Radiation Dose and Low–Contrast Material Dose Abdominal CT in Patients With Cirrhosis

  • Jan 01, 2012
  • Journal of Computer Assisted Tomography
  • Tomohiro Namimoto +6
  • Research Article
  • Citations146

FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection.

  • Feb 01, 2001
  • European Journal of Nuclear Medicine
  • Celso D Ramos +7
  • Research Article
  • Citations140

Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection.

  • Jul 01, 1986
  • Medical Physics
  • Ronald J Jaszczak +4
  • PDF
  • Research Article
  • Citations20

SPECT Imaging of 2-D and 3-D Distributed Sources with Near-Field Coded Aperture Collimation: Computer Simulation and Real Data Validation

  • Jan 01, 2016
  • Journal of Medical and Biological Engineering
  • Zhiping Mu +2
  • Research Article
  • Citations10

Pinhole single-photon emission tomography reconstruction based on median root prior

  • Nov 08, 2002
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Antti Sohlberg +2
  • Conference Article
  • Citations20

Spatial Resolution Properties of FB and ML-EM Reconstruction Methods

  • Jan 01, 1993
  • D.W Wilson +1
  • Research Article

Graph-Enhanced Expectation Maximization for Emission Tomography

  • Jan 20, 2026
  • Journal of Imaging
  • Ryosuke Kasai +1
  • Research Article
  • Citations78

Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT

  • May 01, 1998
  • Journal of Nuclear Cardiology
  • Hidehiro Iida +1
  • Research Article
  • Citations13

Fusion of the MR image to SPECT with possible correction for partial volume effects

  • Feb 01, 2006
  • IEEE Transactions on Nuclear Science
  • P Calvini +3
  • Research Article
  • Citations3

Evaluation of Image Reconstruction Techniques in Single Photon Emission Computed Tomography (SPECT/CT) Imaging

  • Apr 20, 2018
  • Research & Reviews: Journal of Physics
  • F Usman +3
  • Research Article
  • Citations9

On Wiener-type filters in SPECT

  • Feb 01, 2008
  • Inverse Problems
  • J-P Guillement +1
  • Conference Article

Measurements of axisymmetric temperature and H2O concentration distributions on a circular flat flame burner based on tunable diode laser absorption tomography

  • Oct 25, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Huihui Xia +9
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.