• Home
  • Search
  • Large strain analysis of a soft polymer electromechanical sensor coupled to an arterial segment
  • Cite Icon8
  • https://doi.org/10.1177/1045389x12436733Copy DOI Icon

Large strain analysis of a soft polymer electromechanical sensor coupled to an arterial segment

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Dielectric elastomer membranes are one of the most promising transducers for developing soft large strain sensors. In this article, we describe the sensor response for a potential biomedical application. It is widely accepted that diseased arteries at various stages have a unique constitutive response. This means that ideally the output of an in situ artery sensor would have distinct profiles corresponding to various stages of unhealthiness. An in situ sensor can potentially allow access to information about the mechanical state of the artery that is not currently available. Furthermore, the potential to combine the functions of providing structural support (stent) and monitoring the mechanical state (sensor) is appealing. Traditional sensors such as strain gages and piezoelectric sensors are stiff and fail at low strains (<1%), whereas some dielectric elastomers are viable at strains up to and even surpassing 100%. Investigating the electromechanical response of a deformable tube sensor sandwiched between a pulsating pressure source and a nonlinear elastic distensible thick wall has not been attempted before now. The successful development of a multiphysics model that correlates the electrical output of a pulsatile membrane sensor to its state of strain would be a significant breakthrough in medical diagnostics. The artery is described using a structural model for a tubular membrane reinforced with two families of initially crimped fibers subjected to a pulsating pressure profile. In this article, the fundamental mechanics associated with electromechanical coupling during dynamic finite deformations of dielectric elastomers is derived. A continuum model for the dynamic response of tubular dielectric elastomer membranes configured for sensing is presented. The pressure profile leads to a nonlinear response of the artery sensor due to the nonlinear deformation behavior of the arterial wall. At pressures above 13 kPa, the artery undergoes infinitesimal deformation, which leads to very small changes in the sensor signal. In this range, fabricating thinner sensors and synthesizing hybrid polymers with higher dielectric constants can enhance the sensitivity.

Similar Papers
  • Conference Article
  • Citations10

Electromechanical performance analysis of inflated dielectric elastomer membrane for micro pump applications

  • Apr 15, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Abhishek Saini +2
  • Research Article
  • Citations4

Development and validation of a fatigue testing setup for dielectric elastomer membrane actuators

  • Apr 18, 2019
  • Smart Materials and Structures
  • Marc Hill +2
  • Research Article
  • Citations17

Controlling wrinkles on the surface of a dielectric elastomer balloon

  • Jun 09, 2016
  • Extreme Mechanics Letters
  • Guoyong Mao +4
  • Conference Article
  • Citations1

Model-based parameter analysis of dielectric elastomer loudspeakers

  • Jul 11, 2022
  • Giacomo Moretti +1
  • Research Article
  • Citations58

Energy harvesting from a novel contact-type dielectric elastomer generator

  • Dec 10, 2019
  • Energy Conversion and Management
  • C.L Zhang +4
  • Research Article
  • Citations39

A robust dual-membrane dielectric elastomer actuator for large volume fluid pumping via snap-through

  • Nov 20, 2017
  • Applied Physics Letters
  • Zhe Li +3
  • Research Article
  • Citations106

Electro-elastomers: Large deformation analysis of silicone membranes

  • Aug 22, 2006
  • International Journal of Solids and Structures
  • N.C Goulbourne +2
  • Conference Article
  • Citations37

New silicone dielectric elastomers with a high dielectric constant

  • Mar 27, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Zhen Zhang +6
  • Conference Article
  • Citations17

Modeling and Control of Lozenge-Shaped Dielectric Elastomer Generators

  • Sep 16, 2013
  • Giacomo Moretti +2
  • PDF
  • Research Article
  • Citations13

Fully Polymeric Domes as High-Stroke Biasing System for Soft Dielectric Elastomer Actuators

  • Jun 10, 2021
  • Frontiers in Robotics and AI
  • Julian Neu +5
  • Research Article

Electromechanical coupled deformation analysis of a hyper-elastic dielectric membrane under combined pressure and electric loading

  • Jan 01, 2026
  • EPJ Web of Conferences
  • Nirmal Kumar +2
  • Conference Article
  • Citations1

An Investigation on the Aerodynamics, Vibrations, and Control of an Electroactive Membrane

  • Oct 30, 2022
  • Oluwatosin Ojo +3
  • Conference Article
  • Citations4

The area of allowable states in Mooney-Rivlin type dielectric elastomer generators

  • Mar 25, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Liwu Liu +5
  • Research Article
  • Citations7

Role of nonlinear elasticity in mechanical impedance tuning of annular dielectric elastomer membranes

  • Mar 06, 2017
  • Extreme Mechanics Letters
  • A Cugno +4
  • Research Article
  • Citations3

Analytical Modeling of Clamped Dielectric Elastomer Strip Membranes Exhibiting Necking Effect

  • Jan 01, 2018
  • IFAC PapersOnLine
  • Gianluca Rizzello +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.