• Home
  • Search
  • Level Set Method in EIT Image Reconstructions
  • https://doi.org/10.2529/piers091220101350Copy DOI Icon

Level Set Method in EIT Image Reconstructions

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

In present there are a lot of difierent numerical methods, ways and approaches to obtain the stable and efiective image reconstruction process, which can be used for e-cient applications in physical and biological sciences. Electrical Impedance Tomography (EIT) belongs to methods which are very beneflcial, especially in a medical imaging. This method is non-invasive technique and can be used very efiectively for good detection of conductivity tissue changes. Unfortunately the back image reconstruction based on electrical impedance tomography is highly ill-posed inverse problem and it is necessary to flnd such techniques which ofier stable, accurate and not too much time-consuming reconstruction process. This paper proposes new possibilities to improve the stability and the accuracy of today image reconstructions including the level set method. At the present time the image reconstruction problem is a widely investigated problem with many applications in physical and biological sciences. The Electrical Impedance Tomography can be used for reconstruction process. The theoretical background of EIT is given in (1). The currents are applied through the electrodes attached to the surface of the object and the resulting voltages are measured using the same or additional electrodes. An arrangement of EIT system is shown in Fig. 1(left). Finally the internal impedivity distribution is recalculated from the measured voltages and cur- rents. The forward problem is well-posed, but the inverse problem is highly ill-posed. Various numerical techniques with difierent advantages have been developed to solve this problem. The common aim is to reconstruct the impedivity distribution in two or three dimensional models as ac- curately and fast as possible. Usually a set of voltage measurements is acquired from the boundaries of the determined volume, whilst it is subjected to a sequence of low-frequency current patterns, which are preferred to direct current ones to avoid polarization efiects. Since the frequency of the injected current is su-ciently low, usually in the range of 10{100 kHz, EIT can be treated as a quasi-static problem. So we only consider the conductivity ae inside investigated object for simplic- ity. The scalar potential U can be therefore introduced, and so the resulting fleld is conservative and the continuity equation for the volume current density can be expressed by the potential U r ¢ (ae rU) = 0 (1) Equation (1) together with the modifled complete electrode model equations (2) are discretized by the flnite element method (FEM) in the usual way. Using FEM we calculate approximate values of electrode voltages for the approximate element conductivity vector ae(NE), NE is the number of flnite elements. Furthermore, we assume the constant approximation of a conductivity

Similar Papers
  • Dissertation

Robust support identification for direction-of-arrival estimation and EIT application

  • Jan 01, 2020
  • Narong Borijindargoon
  • Conference Article
  • Citations2

Analysis of forward problem for elliptical geometry in EIT by using analytical and finite element methods

  • Dec 27, 2003
  • K.E Akdogan +2
  • Supplementary Content

Algorithms and Numerical Methods for Electrical Brain Imaging

  • May 08, 2017
  • AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna)
  • Andrea Samoré
  • Research Article
  • Citations4

Improvement of performance and sensitivity of 2D and 3D image reconstruction in EIT using EFG forward model

  • Mar 23, 2022
  • Biomedical Physics & Engineering Express
  • M Hadinia +1
  • Book Chapter
  • Citations4

Chapter eight - Electrical impedance tomography image reconstruction based on autoencoders and extreme learning machines

  • Jan 01, 2020
  • Deep Learning for Data Analytics
  • Juliana Carneiro Gomes +5
  • Conference Article

Application of conformal transformation on the analysis of forward problems in electrical impedance tomography

  • Apr 28, 2004
  • K.E Akdogan +2
  • Research Article
  • Citations22

A real-time EIT imaging system based on the split augmented Lagrangian shrinkage algorithm

  • Jun 15, 2017
  • Measurement
  • Yongkang Zhou +1
  • Research Article
  • Citations49

Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography

  • Jan 01, 1999
  • Physiological Measurement
  • H Dehghani +2
  • Research Article
  • Citations21

Image reconstruction using voltage–current system in electrical impedance tomography

  • Aug 17, 2014
  • Nuclear Engineering and Design
  • Bong Seok Kim +4
  • Research Article
  • Citations6

Forward solving in Electrical Impedance Tomography with algebraic multigrid wavelet based preconditioners

  • Apr 01, 2010
  • Journal of Physics: Conference Series
  • A Borsic +1
  • Research Article

Streamlined Gesture and Arm Motion Analysis via Direct EIT Voltage Classification.

  • Jul 01, 2025
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
  • Binh Nguyen +3
  • Conference Article
  • Citations4

Forward and inverse problem solutions for three dimensional electrical impedance tomography

  • Jan 01, 1996
  • K Kleinermann
  • Conference Article

A shape reconstruction method for electrical impedance imaging based on auto-encoder

  • Aug 01, 2022
  • Tao Fang
  • Conference Article
  • Citations12

Image reconstruction algorithm for electrical impedance tomography based on block sparse Bayesian learning

  • Oct 01, 2017
  • Shengheng Liu +2
  • Conference Article

<title>New image reconstruction method in dynamic electrical impedance tomography</title>

  • Sep 04, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Weidong Hou +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.