• Home
  • Search
  • LiDAR measurement system and the calibration method of loading robot
  • Cite Icon2
  • https://doi.org/10.12086/oee.2019.190002Copy DOI Icon

LiDAR measurement system and the calibration method of loading robot

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

To carry out the measurement of vehicle body position and dimension of loading robot before loading, an intelligent vehicle body measurement system based on two-dimensional LiDAR was provided, and the calibration method of this system was studied as a key point. The two-dimension LiDAR was driven by rotating the platform, and the three-dimensional information of car body measured was obtained by using the single two-dimensional laser radar. In allusion to the complexity of calibration method of LiDAR measurement system and the difficulty in making calibration pieces, a system parameter calibration method was proposed based on 321 coordinate system building method, and mathematical models of calibration was established, with the principle and procedure of calibration method in detail. Measurement system was set up in a laboratory to carry out calibration experiment and measurement experiment on simulation vehicle body, and the measurement experiment for real vehicle body was conducted outside. The experiment result shows that the maximum measurement error of vehicle body size and length of this measurement system was 26.4 mm; maximum angle measurement error was 0.18 degree, which fully meets the precision requirements of loading.

Similar Papers
  • Research Article
  • Citations65

Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients

  • Apr 01, 2008
  • Journal of American Association for Pediatric Ophthalmology and Strabismus
  • Maya Eibschitz-Tsimhoni +3
  • Conference Article
  • Citations1

<title>Lidar system for atmospheric turbulence measurement with Mersen telescope</title>

  • Feb 13, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • A V Savin +3
  • Research Article
  • Citations7

Combined non-contact coordinate measurement system and calibration method

  • Feb 23, 2015
  • Optics & Laser Technology
  • Yiyan Fan +1
  • Research Article

Accidental external rotation of distal interlock jig in retrograde femoral nailing can lead to more prominent screws

  • Nov 12, 2018
  • Injury
  • Boshen Liu +3
  • Research Article
  • Citations8

An error compensation method for on-machine measuring blade with industrial robot

  • Jan 01, 2025
  • Measurement
  • Junjie Zhang +4
  • PDF
  • Research Article
  • Citations11

Effects of lower limb and pelvic pin positions on leg length and offset measurement errors in experimental total hip arthroplasty

  • Mar 16, 2021
  • Journal of Orthopaedic Surgery and Research
  • Haruo Kawamura +3
  • Research Article
  • Citations2

Measurement error of mean sac diameter and crown-rump length among pregnant women at Mulago hospital, Uganda

  • May 04, 2018
  • BMC Pregnancy and Childbirth
  • Sam Ali +14
  • Research Article
  • Citations912

Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables

  • Feb 27, 2008
  • Ultrasound in Obstetrics & Gynecology
  • J W Bartlett +1
  • Conference Article
  • Citations1

Calibration methods of near-infrared frequency domain diffused light measurement system

  • Feb 10, 2011
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ying Fan +5
  • Research Article
  • Citations28

Improvement of stereo vision-based position and velocity estimation and tracking using a stripe-based disparity estimation and inverse perspective map-based extended Kalman filter

  • May 07, 2010
  • Optics and Lasers in Engineering
  • Young-Chul Lim +4
  • PDF
  • Research Article
  • Citations3

Adaptive Weighted Data Fusion for Line Structured Light and Photometric Stereo Measurement System.

  • Jun 27, 2024
  • Sensors (Basel, Switzerland)
  • Jianxin Shi +4
  • Research Article
  • Citations13

An optical distance sensor : tilt robust differential confocal measurement with mm range and nm uncertainty

  • Nov 18, 2015
  • Data Archiving and Networked Services (DANS)
  • L.A Cacace
  • Research Article
  • Citations47

Partial discharge. XVIII. Errors in the location of partial discharges in high voltage solid dielectric cables

  • Nov 01, 1993
  • IEEE Electrical Insulation Magazine
  • F.H Kreuger +3
  • Research Article
  • Citations30

Calibration of triaxial MEMS vector field measurement system

  • Nov 01, 2014
  • IET Science, Measurement & Technology
  • Zhang Xiaoming +3
  • Research Article
  • Citations3

Aniseikonia in Intraocular Lens (IOL) Implants: An Optical Analysis

  • Feb 01, 1994
  • European Journal of Implant and Refractive Surgery
  • Vasudevan Lakshminarayanan +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.