Line focal X-ray source imaging

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

High spatial coherent and bright X-ray beam is necessary condition for acquiring high quality radiography image. However, traditional X-ray tube can only provide high flux X-ray light or high spatial coherent light. In general, X-ray photons are generated by using energetic electrons with several tens or even hundreds keV to hit a target. Unfortunately, over 99% electron energy are converted into heat rather than the energy of X-ray photons. Thus, the heat dissipation of the target restricts the emission power and radiation flux. Increasing the emission area of X-ray can relieve the heat dissipation, but it would bring another serious problemlow spatial coherence that is in inverse proportion to emission area or focal spot. In order to solve the conflict between brightness and spatial coherence, an X-ray source with one-dimensional coherence is proposed in this work. The new X-ray source has a special focal spot where one side is small enough to ensure the spatial coherence and the perpendicular side is big enough to provide sufficient X-ray flux. In the direction of long side, the long size of focal spot will result in losing the image details. Consequently, an algorithm of superposition and rotation, in which many images with different rotation angles are added together, is proposed to retrieve the lost information. On the other hand, the spatial transfer function of superposition is analyzed in the frequency domain, and the result shows that the method of superposition can transfer more components of frequency than single image. Based on a traditional X-ray tube, a line focal spot source is designed and fabricated. Two series of experiments are performed for different destinations. After 17 images of a chip with different rotation angles and the line focal spot are collected, those images are rotated in the reverse direction and added together. The image of superposition clearly presents some details which are invisible in one of 17 images. At the same tube voltage and for the same object, some comparative experiments with micro-focus source, line focal spot source and normal focal spot source are presented. Compared with traditional X-ray tube, line focal spot source can provide high-resolution image. In the aspect of image visibility, the new source has definite advantages compared with micro-focus source, despite no improvement in imaging resolution. Finally, the reason for the difference in imaging resolution is discussed from the aspects of spatial coherence and light flux.

Similar Papers
  • Research Article
  • Citations34

Observations on magnification radiography. Visualization of small blood vessels and determination of focal spot size.

  • Mar 01, 1969
  • Radiology
  • Paul J Friedman +1
  • Research Article
  • Citations2

An alignment test jig for measuring the effective focal-spot size of mammographic X-ray tubes

  • May 01, 1989
  • The British Journal of Radiology
  • M L Ramsdale +2
  • Research Article
  • Citations66

Generation and analysis of clinically relevant breast imaging x-ray spectra

  • May 04, 2017
  • Medical physics
  • Andrew M Hernandez +3
  • Research Article
  • Citations30

Method for measuring the focal spot size of an x‐ray tube using a coded aperture mask and a digital detector

  • Mar 23, 2011
  • Medical Physics
  • Paolo Russo +1
  • PDF
  • Research Article
  • Citations5

Single-pulse characterization of the focal spot size of X-ray free-electron lasers using coherent diffraction imaging

  • Mar 22, 2023
  • Journal of Synchrotron Radiation
  • Zichen Gao +12
  • Dissertation

Therapy and medical imaging applications of focusing polycapillary X-Ray optics

  • Jan 01, 2021
  • Weiyuan Sun
  • Research Article
  • Citations1

Overcoming the thermal limits of photon counting CT resolution using focal spot multiplexing: A feasibility study.

  • Jan 25, 2025
  • Medical physics
  • Scott S Hsieh
  • Research Article
  • Citations5

A Monte Carlo study of the influence of focal spot size, intensity distribution, breast thickness and magnification on spatial resolution of an a-Se digital mammography system using the generalized MTF

  • Sep 05, 2013
  • Physica Medica
  • T Sakellaris +3
  • Research Article
  • Citations14

Slit camera focal spot measurement errors in mammography

  • Nov 01, 1995
  • Medical Physics
  • S Tang +2
  • Research Article
  • Citations27

The effect of x‐ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging

  • Mar 20, 2009
  • Medical Physics
  • Kostas Perisinakis +2
  • Conference Article

Novel beam analysis applications and hardware

  • Jan 01, 2009
  • Thomas R Kugler
  • Research Article
  • Citations29

High power, high uniformity strip electron gun design, simulation and performance

  • Jan 01, 2001
  • Review of Scientific Instruments
  • K B Thakur +3
  • Research Article
  • Citations26

Correction for Resolution Nonuniformities Caused by Anode Angulation in Computed Tomography

  • Sep 01, 2008
  • IEEE Transactions on Medical Imaging
  • P.J La Riviere +1
  • Book Chapter

Speckle-Free Digital Holographic Phase Microscopy and Tomography Using Partially Spatially Coherent Monochromatic Light with Improved Image Sharpness, Resolution and Phase Noise

  • Jan 01, 2021
  • Dalip Singh Mehta
  • Research Article
  • Citations8

RETRACTED ARTICLE: Modelling and verification of white light oil immersion microsphere optical nanoscope

  • Oct 30, 2017
  • Optical and Quantum Electronics
  • Jinzhong Ling +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.