• Home
  • Search
  • Long term dga trend evaluation of transmission power transformers
  • Cite Icon2
  • https://doi.org/10.1049/icp.2022.0234Copy DOI Icon

Long term dga trend evaluation of transmission power transformers

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The deterioration of transformer insulation materials results in the formation of gases and oxidation products. The main gases are hydrogen, hydrocarbons and carbon oxides. The gases are dissolved in the transformer oil and they are periodically measured for transformer health assessment, which is known as Dissolved Gas Analysis (DGA). In this paper, a study was performed to determine the influence of the transformer service age on the DGA trends. Around 40,000 DGA data samples from 672 in-service transmission power transformers, from new transformers up to 63 years in service in the UK, were used in this study. The 50th, 75th and 90th percentile values of gas level were computed for each gas in ppm at every service age in years to understand the central tendency of gassing trends along with the service age. In this analysis, three trend patterns were observed. Firstly, hydrogen values are independent of the service age. Secondly, methane, ethane and ethylene tend to stay constant up to around 50 years, before increasing noticeably. Finally, carbon oxides increase gradually with a decremental rate. These observations provide insights into incorporating transformer age in substantiating DGA based condition assessment.

Similar Papers
  • Conference Article
  • Citations27

The side effects of gassing in transmission power transformers

  • Oct 15, 2000
  • J Sabau +1
  • Conference Article

On the transmission power transformers in Nigeria: Lagos sub region as case study

  • Jun 01, 2016
  • T R Ayodele +2
  • Research Article
  • Citations16

Surge analysis for lightning strike on overhead lines of wind farm

  • Feb 05, 2021
  • Electric Power Systems Research
  • Qiuqin Sun +6
  • Conference Article
  • Citations2

Protection relay stability study for 115kV and 34.5kV transmission and distribution system

  • Oct 01, 2011
  • Sin-Jo Jung +1
  • Conference Article
  • Citations6

Romanian innovative system for power losses real time monitoring and analysis in electrical transmission and distribution systems

  • Jun 16, 2021
  • Constantin Moldoveanu +6
  • Conference Article
  • Citations1

Development of Measures to Optimize the Transformers Loading

  • May 16, 2022
  • Azat Salavatovich Khismatullin
  • Conference Article
  • Citations7

Influence of aging degree on polarization and depolarization currents of oil-paper insulation

  • Oct 01, 2013
  • Li Xiao +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.