• Home
  • Search
  • M-beat-A novel marker for selective left bundle branch capture.
  • Cite Icon9
  • https://doi.org/10.1111/jce.15597Copy DOI Icon

M-beat-A novel marker for selective left bundle branch capture.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Premature-ventricular-complexes (template/fixation beat) guided left bundle branch pacing (LBBP) was recently described as a novel method of successful lead deployment by rapid rotations. We aimed at analyzing the incidence of a unique morphology template beat, which we labelled as 'M-beat' in patients undergoing PVC-guided LBBP, its ability to predict selective LBB-capture and clinical significance. Overall 210 out of 217 attempted-patients (96.7%) underwent successful LBBP. Template beat was noted in 90.4% patients (n = 190) and M-beat in 32.8%(n = 69). Non-selective to selective capture transition demonstrated in 55.2%(n = 116). The QRS duration of the M-beat was 129.3 ± 13.1ms. Patients were divided into two groups: Group-I with M-beat (n = 69;32.8%) and Group-II without M-beat (n = 141; 67.2%). The mean fluoroscopy-time was significantly less in group-I as compared to group-II (13.1 ± 11.1 vs 16.8 ± 12.04 minutes; p-0.03). Patients in group-II required more attempts as compared to group-I for successful lead deployment (2.8 ± 1.09 vs 2.2 ± 1.04; p - 0.01). Six patients showed loss of R-wave in lead-V1 and 2 showed rise in LBB capture threshold by >1V during follow-up in group-II. M-beat had a specificity of 96.77% and sensitivity of 58.62% (positive-predictive-value-98.55%) to predict selective-LBB capture. Myocardial excitability would not modify the occurrence of M-beat as opposed to capture transition response since it could be demonstrated without pacing protocols. When confirmation of LBB-capture itself would be difficult in patients with baseline LBBB-morphology, M-beat with 42.8% incidence predicted selective capture with 96.7% specificity and 66.04% sensitivity(positive-predictive-value-97.22%). M-beat is a marker of transient-selective LBB-capture, independent of the local myocardial excitability with high specificity and positive predictive value irrespective of the baseline QRS morphology.

Similar Papers
  • Discussion
  • Citations47

Template Beat: A Novel Marker for Left Bundle Branch Capture During Physiological Pacing.

  • Apr 01, 2021
  • Circulation: Arrhythmia and Electrophysiology
  • Shunmuga Sundaram Ponnusamy +4
  • Research Article

B-011-23 QRS CHARACTERISTICS DURING LEFT BUNDLE BRANCH PACING WITH AND WITHOUT BIDIRECTIONAL LEFT INTRAHISIAN BLOCK

  • Aug 01, 2021
  • Heart Rhythm
  • Weiping Sun +6
  • Research Article
  • Citations28

A Continuous Pacing and Recording Technique for Differentiating Left Bundle Branch Pacing From Left Ventricular Septal Pacing: Electrophysiologic Evidence From an Intrapatient-Controlled Study.

  • Jan 01, 2023
  • Canadian Journal of Cardiology
  • Jiabo Shen +5
  • Research Article
  • Citations65

Electrophysiological characteristics and clinical values of left bundle branch current of injury in left bundle branch pacing.

  • Feb 10, 2020
  • Journal of Cardiovascular Electrophysiology
  • Lan Su +9
  • Research Article

Abstract 13984: The Feasibility and Safety of Left Bundle Branch Pacing in Patients With Tricuspid Valve Disease

  • Nov 16, 2021
  • Circulation
  • Xueying Chen +2
  • Research Article
  • Citations1

Electrogram transition patterns in left bundle branch pacing: a case report

  • May 30, 2025
  • BMC Cardiovascular Disorders
  • Jiabo Shen +3
  • Research Article
  • Citations7

Increased capture threshold in permanent His-bundle pacing associated with flecainide.

  • Feb 17, 2020
  • Pacing and Clinical Electrophysiology
  • Michael Jiang +3
  • Research Article
  • Citations21

Development and evaluation of an EHR-based computable phenotype for identification of pediatric Crohn's disease patients in a National Pediatric Learning Health System.

  • Aug 28, 2020
  • Learning Health Systems
  • Ritu Khare +8
  • Research Article
  • Citations2

Comparative Evaluation of the Radiographic Parameters for Screening Early Blount Disease.

  • Feb 03, 2022
  • Journal of Pediatric Orthopaedics
  • Jidapa Wongcharoenwatana +4
  • Research Article
  • Citations26

A simple laboratory measurement for discrimination of transudative and exudative pleural effusion: Pleural viscosity

  • Nov 21, 2005
  • Respiratory Medicine
  • Ozkan Yetkin +4
  • Research Article
  • Citations515

The sensitivity, specificity, and predictive value of traditional clinical evaluation of peripheral arterial disease: results from noninvasive testing in a defined population.

  • Mar 01, 1985
  • Circulation
  • M H Criqui +4
  • Research Article
  • Citations3

Assessment of the applicability of transthoracic lung ultrasound for diagnosing purulent lobar pneumonia – A case study

  • Jan 01, 2020
  • Polish Annals of Medicine
  • Jolanta Grabala +3
  • Research Article

SCREENING: THE CORNERSTONE FOR SECONDARY PREVENTION

  • Dec 31, 2018
  • Gomal Journal of Medical Sciences
  • Iftikhar Ahmad
  • Research Article
  • Citations9

Novel utility of Vesical Imaging-Reporting and Data System in multimodal treatment for muscle-invasive bladder cancer.

  • Apr 13, 2023
  • European radiology
  • Koichiro Kimura +12
  • Research Article

CT-MIBI Image Fusion: Transmission and Emission Tomography for Localization of Bronchogenic Carcinoma and Nodal Metastasis

  • Jun 01, 2006
  • Clinical Nuclear Medicine
  • Rajnish Sharma +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.