• Home
  • Search
  • MCI Detection Using Kernel Eigen-Relative-Power Features of EEG Signals
  • Open Access IconOpen Access
  • Cite Icon14
  • https://doi.org/10.3390/act10070152Copy DOI Icon

MCI Detection Using Kernel Eigen-Relative-Power Features of EEG Signals

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Classification between individuals with mild cognitive impairment (MCI) and healthy controls (HC) based on electroencephalography (EEG) has been considered a challenging task to be addressed for the purpose of its early detection. In this study, we proposed a novel EEG feature, the kernel eigen-relative-power (KERP) feature, for achieving high classification accuracy of MCI versus HC. First, we introduced the relative powers (RPs) between pairs of electrodes across 21 different subbands of 2-Hz width as the features, which have not yet been used in previous MCI-HC classification studies. Next, the Fisher’s class separability criterion was applied to determine the best electrode pairs (five electrodes) as well as the frequency subbands for extracting the most sensitive RP features. The kernel principal component analysis (kernel PCA) algorithm was further performed to extract a few more discriminating nonlinear principal components from the optimal RPs, and these components form a KERP feature vector. Results carried out on 51 participants (24 MCI and 27 HC) show that the newly introduced subband RP feature showed superior classification performance to commonly used spectral power features, including the band power, single-electrode relative power, and also the RP based on the conventional frequency bands. A high leave-one-participant-out cross-validation (LOPO-CV) classification accuracy 86.27% was achieved by the RP feature, using a simple linear discriminant analysis (LDA) classifier. Moreover, with the same classifier, the proposed KERP further improved the accuracy to 88.24%. Finally, cascading the KERP feature to a nonlinear classifier, the support vector machine (SVM), yields a high MCI-HC classification accuracy of 90.20% (sensitivity = 87.50% and specificity = 92.59%). The proposed method demonstrated a high accuracy and a high usability (only five electrodes are required), and therefore, has great potential to further develop an EEG-based computer-aided diagnosis system that can be applied for the early detection of MCI.

Loading PDF

Similar Papers
  • Conference Article
  • Citations26

A robust kernel PCA algorithm

  • Aug 26, 2004
  • Cong-De Lu +3
  • Research Article
  • Citations30

Spatio-Temporal Fluctuations of Neural Dynamics in Mild Cognitive Impairment and Alzheimer's Disease.

  • Aug 22, 2017
  • Current Alzheimer Research
  • Jesús Poza +6
  • Book Chapter
  • Citations75

Electroencephalogram (EEG) Signal Analysis for Diagnosis of Major Depressive Disorder (MDD): A Review

  • Aug 02, 2018
  • Shalini Mahato +1
  • Conference Article
  • Citations25

Face recognition using kernel principal component analysis and genetic algorithms

  • Jun 25, 2003
  • Zhang Yankun +1
  • Research Article

Stability of Magnetoencephalography and Electroencephalography Spectral Features in Mild Cognitive Impairment

  • Dec 01, 2023
  • Alzheimer's & Dementia
  • Antti S Kinnunen +8
  • Research Article
  • Citations30

Features of the superficial white matter as biomarkers for the detection of Alzheimer's disease and mild cognitive impairment: A diffusion tensor imaging study

  • Jan 01, 2022
  • Heliyon
  • Bahare Bigham +2
  • PDF
  • Research Article
  • Citations25

Integrating Biomarkers From Virtual Reality and Magnetic Resonance Imaging for the Early Detection of Mild Cognitive Impairment Using a Multimodal Learning Approach: Validation Study

  • Apr 17, 2024
  • Journal of Medical Internet Research
  • Bogyeom Park +6
  • Book Chapter
  • Citations20

EEG Wavelet Spectral Analysis During a Working Memory Tasks in Stroke-Related Mild Cognitive Impairment Patients

  • Dec 18, 2015
  • N K Al-Qazzaz +4
  • Research Article
  • Citations48

Plasma d-glutamate levels for detecting mild cognitive impairment and Alzheimer's disease: Machine learning approaches.

  • Feb 15, 2021
  • Journal of Psychopharmacology
  • Chun-Hung Chang +7
  • Conference Article
  • Citations21

Content Based Image Retrieval for MR Image Studies of Brain Tumors

  • Aug 01, 2006
  • Shishir Dube +3
  • Conference Article
  • Citations15

Expert System Based Intrusion Detection System

  • Nov 01, 2010
  • Hou Yong +1
  • Research Article
  • Citations1

Comparison of machine learning algorithms for predicting cognitive impairment using neuropsychological tests

  • Sep 06, 2024
  • Applied Neuropsychology: Adult
  • Chanda Simfukwe +2
  • Research Article

A Review on EEG-Based Techniques for Early Dementia Classification Using Machine Learning Approaches

  • Jun 24, 2025
  • International Research Journal on Advanced Engineering and Management (IRJAEM)
  • Mrs Kulsoom Fathima +1
  • PDF
  • Research Article
  • Citations20

Multiple cross-frequency coupling analysis of resting-state EEG in patients with mild cognitive impairment and Alzheimer's disease.

  • Aug 04, 2023
  • Frontiers in Aging Neuroscience
  • Xi Chen +6
  • Conference Article
  • Citations1

Classification of mild cognitive impairment and normal by pattern recognition of EEG Lemple-Ziv complexity and alpha power

  • Jan 01, 2013
  • Jun Yang +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.