  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Mechanical and biomechanical testing provides crucial information about the safety, effectiveness and function of spinal implants. Mainly static and dynamic tests are carried out. While mechanical tests may be carried out according to testing standards or in some cases to individual testing procedures, biomechanical tests should be conducted according to published recommendations or in case of dynamic testing, as individual test procedures. In order to allow for direct comparison between testing laboratories, it should be strived for standardised testing. However, as standardised loading often simplifies the in vivo occurring conditions, more physiological testing can be carried out additionally and may become the next improved testing standard. Mechanical testing focuses mainly on the safety issue, while effectiveness and function of an implant can be tested in a biomechanical setup. Each type of implant generally requires specific mechanical and biomechanical tests depending on its design, material, indication and function. In general, mechanical testing can be subdivided in static and dynamic fatigue testing as well as special types of testing such as wear or corrosion testing. Biomechanical testing concentrates on quasi-static and short-term dynamic testing mostly in interaction with biological tissue.

Similar Papers
  • Research Article
  • Citations128

Fatigue Life of Reciproc and Mtwo Instruments Subjected to Static and Dynamic Tests

  • Feb 08, 2013
  • Journal of Endodontics
  • Hélio P Lopes +9
  • PDF
  • Research Article
  • Citations37

Tensile behaviour of soda-lime-silica glass and the significance of load duration – A literature review

  • Jul 22, 2021
  • Journal of Building Engineering
  • Martin J Meyland +2
  • Research Article
  • Citations1

Performance of CVD Mullite Coatings on Silicon Nitride under High Temperature High Load Conditions

  • Jun 01, 2005
  • Key Engineering Materials
  • S.M Zemskova +3
  • Conference Article

Application of Electron Microscopy for the Analysis of the Mechanical Behavior of Advanced Ceramics

  • Jun 06, 1988
  • V J Tennery +3
  • Research Article
  • Citations14

In situ deformation of growth plate chondrocytes in stress-controlled static vs dynamic compression

  • Mar 11, 2017
  • Journal of Biomechanics
  • Elizabeth A Zimmermann +5
  • Research Article
  • Citations20

Comparison between fatigue behavior of some ceramics: a new concept of intrinsic stress-corrosion exponent n0

  • Mar 06, 2002
  • International Journal of Fatigue
  • G.J Qiao
  • Research Article
  • Citations18

Solution Casting Blending: An Effective Way for Tailoring Gas Transport and Mechanical Properties of Poly(vinyl butyral) and Pebax2533

  • Apr 19, 2019
  • The Journal of Physical Chemistry C
  • Gabriele Clarizia +4
  • Research Article
  • Citations4

Correlation between AFM characterizations and dynamic mechanical testing to assess the ductile-to-brittle transition during ABS photodegradation

  • Aug 09, 2024
  • Polymer Degradation and Stability
  • Laëtitia Delarue +6
  • Research Article
  • Citations8

Time-dependent mechanical behaviour of alumina ceramics

  • Jan 01, 1991
  • Engineering Fracture Mechanics
  • A.T Yokobori +2
  • Research Article
  • Citations143

Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design.

  • Jun 01, 2000
  • Journal of Spinal Disorders
  • Stephen D Cook +3
  • Research Article
  • Citations18

A Linear Laser Scanner to Measure Cross-Sectional Shape and Area of Biological Specimens During Mechanical Testing

  • Sep 10, 2010
  • Journal of Biomechanical Engineering
  • Claudio Vergari +6
  • Research Article

In vitro short term cartilage tissue engineering with oriented cartilage extracellular matrix scaffolds and bone marrow mesenchymal stem cells

  • Dec 01, 2010
  • Chinese Journal of Orthopaedics
  • Jun Yao +7
  • Research Article
  • Citations8

Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures

  • Dec 05, 2014
  • Chinese Medical Journal
  • Ying Chen +6
  • Conference Article
  • Citations20

Recommended Practice for Dynamic Testing for Sheet Steels - Development and Round Robin Tests

  • Apr 03, 2006
  • SAE technical papers on CD-ROM/SAE technical paper series
  • B Yan +5
  • Research Article
  • Citations10

A five-parameter fractional derivative temperature spectrum model for polymeric damping materials

  • May 29, 2020
  • Polymer Testing
  • Heng Zhang +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.