• Home
  • Search
  • Mechanical effects of stem cement interface characteristics in total hip replacement.
  • Open Access IconOpen Access
  • Cite Icon104
  • https://doi.org/10.1097/00003086-199608000-00040Copy DOI Icon

Mechanical effects of stem cement interface characteristics in total hip replacement.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Stem cement debonding is 1 of the most common forms of fixation failure and is thought to be a prelude to gross loosening of a total hip reconstruction. However, the immediate consequences of debonding remains a matter of controversy. The dynamic effects of stem cement debonding in total hip reconstruction were analyzed using 3-dimensional finite element techniques. Stem cement interface conditions were assumed as completely bonded or unbonded, with or without friction. The dynamic effects were accounted for, as presented by the stance and swing phases of the gait cycle. It was found that both cyclic micromotions at the stem cement interface and stresses in the cement mantle were effectively reduced by friction. The friction cases produced failure probabilities of the cement mantle that were relatively close to the one generated by the bonded stem. The probability of mechanical failure of the cement bone interface decreased after debonding and decreased more with reduced stem cement friction. These results show that, although a firm and lasting bond between stem and cement may be desirable for preventing cement failure, the mechanical effects of a debonded stem are less detrimental than were assumed earlier. For straight tapered stem shapes subjected to the loading conditions described, a polished stem may be desirable for the cement bone interface mechanics.

Similar Papers
  • Research Article
  • Citations49

The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses

  • Aug 05, 2009
  • Journal of Biomechanics
  • A Ramos +1
  • Research Article
  • Citations5

Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem–cement debonding

  • Dec 15, 1998
  • Journal of Biomedical Materials Research
  • N Verdonschot +2
  • Research Article
  • Citations41

Fatigue crack growth rate does not depend on mantle thickness: an idealized cemented stem construct under torsional loading

  • Jan 30, 2002
  • Journal of Orthopaedic Research
  • Justin Hertzler +2
  • Research Article
  • Citations18

Bone creep and short and long term subsidence after cemented stem total hip arthroplasty (THA)

  • Jan 26, 2013
  • Journal of Biomechanics
  • T.L Norman +4
  • Research Article
  • Citations6

Femoral Stem Displacement During Closed Reduction of a Dislocated Bipolar Hemiarthroplasty of the Hip

  • Feb 01, 2010
  • Orthopedics
  • Ho Hyun Yun +3
  • Research Article
  • Citations34

The significance of stem-cement loosening of grit-blasted femoral components.

  • Nov 01, 2000
  • Orthopedics
  • Thomas P Schmalzried +2
  • Research Article
  • Citations46

Understanding initiation and propagation of fretting wear on the femoral stem in total hip replacement

  • Jul 24, 2008
  • Wear
  • H Zhang +4
  • Research Article
  • Citations29

Characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems

  • Dec 07, 2013
  • Journal of the Mechanical Behavior of Biomedical Materials
  • M Bryant +6
  • Research Article
  • Citations13

Precooling of the femoral canal enhances shear strength at the cement–prosthesis interface and reduces the polymerization temperature

  • Jan 01, 2006
  • Journal of Orthopaedic Research
  • Pang-Hsin Hsieh +5
  • Research Article
  • Citations2

Wedge Episiotomy for Long Cemented Femoral Stem Removal and Reconstruction. A Case Report on One-Stage Revision for Failed Bipolar for Proximal Femur Giant Cell Tumor

  • Oct 01, 2022
  • Journal of Orthopaedic Case Reports
  • Kalaivanan Kanniyan +1
  • Research Article
  • Citations47

Distal stem design and the torsional stability of cementless femoral stems

  • Aug 01, 1995
  • The Journal of Arthroplasty
  • J Barton Kendrick +2
  • Research Article
  • Citations7

Prevention of thromboembolism.

  • Feb 01, 1973
  • Archives of surgery (Chicago, Ill. : 1960)
  • Charles M Evarts
  • Research Article
  • Citations3

Effect of the Residual Stresses at the Stem–Cement Interface on the Mechanical Behaviour of Cemented Hip Femoral Prosthesis

  • Jul 15, 2015
  • International Journal of Engineering Research in Africa
  • Mohamed Mokhtar Bouziane +5
  • Research Article
  • Citations151

POROSITY REDUCTION IN BONE CEMENT AT THE CEMENT-STEM INTERFACE

  • May 01, 1996
  • The Journal of Bone and Joint Surgery. British volume
  • N E Bishop +2
  • Research Article
  • Citations38

Fatigue failure analysis of a specific total hip prosthesis stem design

  • Nov 22, 2007
  • International Journal of Fatigue
  • S Griza +6
Cactus Communications logo