• Home
  • Search
  • Megavoltage computed tomography: an emerging tool for image-guided radiotherapy.
  • Cite Icon32
  • https://doi.org/10.1097/coc.0b013e3180546770Copy DOI Icon

Megavoltage computed tomography: an emerging tool for image-guided radiotherapy.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Helical tomotherapy is a unique approach to image-guided IMRT that combines features of a linear accelerator and a CT scanner. This design allows generation of megavoltage CT (MVCT) images, which among other uses, are used to verify daily setup. In this study, we assessed the image-quality, absorbed radiation doses, and clinical practicality of MVCT from our helical tomotherapy prototype unit. Phantom studies were first performed to assess the capabilities of MVCT. Next, MVCT images from human patients prospectively enrolled on institutional review board-approved imaging and treatment protocols were analyzed. MVCT was obtained using a 4-MV beam from the University of Wisconsin helical tomotherapy prototype device. These scans were compared with conventional kilovoltage (kVCT) images from a diagnostic CT scanner. MVCT images in phantoms demonstrate an ability to detect contrast differences as small as 3%. Small objects, 1.2 to 1.6 mm, were seen with good resolution. In human subjects, MVCT imaging of tumor targets and normal anatomy revealed sufficient detail for patient repositioning. MVCT imaging of metallic objects showed minimal artifact in comparison with kVCT. Patient scans were obtained in about 1 to 5 minutes and resulted in absorbed radiation doses of 1.5 to 3 cGy. MVCT is an elegant pretreatment position and setup verification tool. MVCT images of human subjects obtained from the helical tomotherapy unit showed good resolution and contrast. The high-quality three-dimensional information permits its use in day-to-day setup verification. The unique properties of MVCT also provide the potential for primary imaging of anatomic regions near metal prostheses as well as nonmedical applications. Additional investigations are underway to improve image quality, further reduce patient dose, and aid adaptive radiotherapy and dose reconstruction.

Similar Papers
  • Research Article
  • Citations51

Megavoltage Computed Tomography Imaging: A Potential Tool to Guide and Improve the Delivery of Thoracic Radiation Therapy

  • Mar 01, 2004
  • Clinical lung cancer
  • James S Welsh +9
  • Research Article

SU‐E‐T‐802: Dosimetric Examination and Verification of Megavoltage Computed Tomography (MVCT) Based IMRT Treatment Planning with Helical TomoTherapy

  • Jun 01, 2011
  • Medical Physics
  • M Chao +6
  • Research Article
  • Citations1

SU‐FF‐T‐169: Dose Calculation Accuracy in the Presence of High‐Z Materials Using Megavoltage CT for Treatment Planning

  • Jun 01, 2006
  • Medical Physics
  • R Hecox +3
  • Research Article
  • Citations3

DeCoGAN: MVCT image denoising via coupled generative adversarial network

  • Jul 09, 2024
  • Physics in Medicine & Biology
  • Kunpeng Zhang +2
  • Research Article

Megavoltage CT enhancement for cervical cancer tomotherapy using a generative adversarial network with deformable convolution and self-attention.

  • Apr 01, 2026
  • Medical physics
  • Wanwei Jian +8
  • Research Article
  • Citations4

Megavoltage Computed Tomography Image-based Low-dose Rate Intracavitary Brachytherapy Planning for Cervical Carcinoma

  • Apr 01, 2009
  • Technology in Cancer Research & Treatment
  • Thomas H Wagner +8
  • Research Article
  • Citations2

The effects of mega-voltage CT scan parameters on offline adaptive radiation therapy.

  • Feb 09, 2024
  • Radiological Physics and Technology
  • Kento Hoshida +4
  • Research Article
  • Citations14

Improving dose calculations on tomotherapy MVCT images

  • Sep 06, 2012
  • Journal of Applied Clinical Medical Physics
  • F Crop +2
  • Research Article
  • Citations10

High-dose-rate prostate brachytherapy in a patient with bilateral hip prostheses planned using megavoltage computed tomography images acquired with a helical tomotherapy unit

  • Nov 28, 2008
  • Brachytherapy
  • Rick Holly +4
  • Research Article
  • Citations21

Modeling set-up error by daily MVCT for prostate adjuvant treatment delivered in 20 fractions: Implications for the assessment of the optimal correction strategies

  • Sep 18, 2009
  • Radiotherapy and Oncology
  • Sara Broggi +7
  • Research Article

SU‐FF‐J‐116: Image‐Guided Adaptive Radiation Therapy for Improving Level I Lymph Node Coverage for Head and Neck Cases

  • May 26, 2005
  • Medical Physics
  • D Chase +3
  • Research Article

WE-C-AUD C-07: Expected Clinical Impact of the Differences Between Planned and Delivered Dose Distributions in Helical Tomotherapy

  • Jun 01, 2008
  • Medical Physics
  • N Papanikolaou +2
  • Research Article
  • Citations12

Evaluation of metal artifacts in MVCT systems using a model based correction method

  • Sep 27, 2012
  • Medical Physics
  • M R Paudel +3
  • Research Article
  • Citations1

Endobiliary Stent: Marker for Patient Alignment in Image-Guided Radiotherapy in Pancreatic and Periampullary Cancers

  • Jun 04, 2013
  • Journal of Gastrointestinal Cancer
  • Pragya Shukla +3
  • Research Article
  • Citations173

Helical tomotherapy: an innovative technology and approach to radiation therapy.

  • Aug 01, 2002
  • Technology in Cancer Research & Treatment
  • James S Welsh +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.