• Home
  • Search
  • Method for testing small light spot produced by optical systems of high NA
  • https://doi.org/10.1117/12.649829Copy DOI Icon

Method for testing small light spot produced by optical systems of high NA

  • Abstract
  • Literature Map
  • Similar Papers
Abstract

We report a method for testing small light spot produced by an optical system with high numerical-aperture (NA). A high NA objective was used to converge the incident linear polarized light, and a tapered optical fiber probe with an opening of 50-80 nm mounted in the near-field optical microscopy (SNOM) apparatus was used to measure light intensity. The small light spot can be measured with high spatial resolution. The results show that a resolution of 50~100 nm can be obtained.

Similar Papers
  • Research Article
  • Citations47

Subwavelength focusing of a spatio-temporal wave packet with transverse orbital angular momentum.

  • Jun 05, 2020
  • Optics Express
  • Jian Chen +3
  • Conference Article

Automated aberration compensation in high numerical aperture systems for arbitrary laser modes (Conference Presentation)

  • Apr 28, 2017
  • Julian Hering +2
  • Research Article
  • Citations4

Hybrid-type 3-axis actuator for active tilt compensation in optical pickup

  • Dec 11, 2007
  • Mechatronics
  • Kyung Taek Lee +3
  • Research Article
  • Citations12

Fabrication of microneedles using two photon-polymerization with low numerical aperture

  • Nov 01, 2023
  • Optics Communications
  • Zewei He +2
  • Conference Article
  • Citations5

On topography characterization of micro-optical elements with large numerical aperture using digital holographic microscopy

  • Apr 26, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • K Liżewski +3
  • Conference Article

Generation of optical needle with wavelength magnitude by tight focusing of circular partially coherent beams

  • May 17, 2019
  • Huichuan Lin +3
  • Research Article
  • Citations4

Focusing properties of radially polarized Bessel-like beam with radial cosine phase wavefront by a high numerical aperture objective

  • May 24, 2017
  • Optical and Quantum Electronics
  • E M El Halba +3
  • Book Chapter
  • Citations7

Imaging with a High Numerical-Aperture Objective

  • Jan 01, 2000
  • Min Gu
  • Conference Article
  • Citations10

Double patterning at NA 0.33 versus high-NA single exposure in EUV lithography: an imaging comparison

  • Mar 19, 2018
  • Weimin Gao +7
  • Research Article
  • Citations5

Topographic optical profilometry of steep slope micro-optical transparent surfaces.

  • Apr 03, 2015
  • Optics express
  • Juan Carlos Martínez Antón +2
  • Research Article

Analysis of Phase Distribution of Focused Light in High Numerical Aperture Systems

  • May 01, 2010
  • Key Engineering Materials
  • Alexander Normatov +2
  • Conference Article
  • Citations1

Optical biosensor based on localized surface plasmon resonance with high spatial resolution

  • Jun 16, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xin Hong +1
  • Research Article
  • Citations45

Microscopic optical coherence tomography (mOCT) at 600 kHz for 4D volumetric imaging and dynamic contrast.

  • Sep 07, 2021
  • Biomedical Optics Express
  • Michael Münter +9
  • PDF
  • Research Article
  • Citations67

Three-dimensional super-resolution longitudinal magnetization spot arrays

  • Aug 01, 2017
  • Light, Science & Applications
  • Zhong-Quan Nie +10
  • Research Article
  • Citations11

Low energy-density recording with a high-repetition-rate laser beam in gold-nanorod-embedded discs

  • Oct 11, 2012
  • Optics Express
  • Md Azim Ullah +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.