Method for transforming CT images for attenuation correction in PET/CT imaging

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A tube-voltage-dependent scheme is presented for transforming Hounsfield units (HU) measured by different computed tomography (CT) scanners at different x-ray tube voltages (kVp) to 511 keV linear attenuation values for attenuation correction in positron emission tomography (PET) data reconstruction. A Gammex 467 electron density CT phantom was imaged using a Siemens Sensation 16-slice CT, a Siemens Emotion 6-slice CT, a GE Lightspeed 16-slice CT, a Hitachi CXR 4-slice CT, and a Toshiba Aquilion 16-slice CT at kVp ranging from 80 to 140 kVp. All of these CT scanners are also available in combination with a PET scanner as a PET/CT tomograph. HU obtained for various reference tissue substitutes in the phantom were compared with the known linear attenuation values at 511 keV. The transformation, appropriate for lung, soft tissue, and bone, yields the function 9.6 x 10(-5). (HU+ 1000) below a threshold of approximately 50 HU and a (HU+ 1000)+b above the threshold, where a and b are fixed parameters that depend on the kVp setting. The use of the kVp-dependent scaling procedure leads to a significant improvement in reconstructed PET activity levels in phantom measurements, resolving errors of almost 40% otherwise seen for the case of dense bone phantoms at 80 kVp. Results are also presented for patient studies involving multiple CT scans at different kVp settings, which should all lead to the same 511 keV linear attenuation values. A linear fit to values obtained from 140 kVp CT images using the kVp-dependent scaling plotted as a function of the corresponding values obtained from 80 kVp CT images yielded y = 1.003 x -0.001 with an R2 value of 0.999, indicating that the same values are obtained to a high degree of accuracy.

Similar Papers
  • Research Article
  • Citations8

Nanoparticles: Untying the Gordian Knot in Conventional Computed Tomography Imaging

  • May 11, 2021
  • CCS Chemistry
  • Zhen Sun +5
  • Research Article
  • Citations123

Small-animal positron emission tomography as a tool for neuropharmacology

  • Jul 06, 2010
  • Trends in Pharmacological Sciences
  • Sophie Lancelot +1
  • Research Article
  • Citations7

Impact of contrast material volume on quantitative assessment of reperfused acute myocardial infarction using delayed-enhancement 64-slice CT: experience in a porcine model

  • Dec 16, 2009
  • La radiologia medica
  • C Martini +12
  • Research Article
  • Citations35

Comparison of Alignment of Computer-registered Data Sets: Combined PET/CT versus Independent PET and CT of the Thorax

  • Nov 01, 2005
  • Radiology
  • Vikram Krishnasetty +3
  • Research Article
  • Citations60

Computed Tomography as a Core Analysis Tool: Applications, Instrument Evaluation, and Image Improvement Techniques

  • Sep 01, 1988
  • Journal of Petroleum Technology
  • Patricia K Hunt +2
  • Research Article
  • Citations4

Validation of the influence of CT slice thickness on the quantitative accuracy and image quality of single photon emission computed tomography.

  • Jan 01, 2021
  • Asia Oceania journal of nuclear medicine & biology
  • Tomohiro Sato +1
  • Research Article
  • Citations29

Detection of Metastases from Gastrointestinal Neuroendocrine Tumors: Prospective Comparison of 18F-TOCA PET, Triple-Phase CT, and PET/CT

  • Jun 01, 2007
  • Technology in Cancer Research & Treatment
  • Marcus D Seemann
  • Research Article

Abstract 4225: Periadventitial Adipose Tissue Inflammation Assessed By 64-slice Computed Tomography Is Associated With Coronary Artery Atherosclerosis

  • Oct 28, 2008
  • Circulation
  • Masaaki Konishi +15
  • PDF
  • Research Article
  • Citations49

Feasibility of using abbreviated scan protocols with population-based input functions for accurate kinetic modeling of [18F]-FDG datasets from a long axial FOV PET scanner

  • Oct 04, 2022
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Hasan Sari +9
  • PDF
  • Research Article
  • Citations17

Fabrication of 3D printed head phantom using plaster mixed with polylactic acid powder for patient-specific QA in intensity-modulated radiotherapy

  • Oct 19, 2022
  • Scientific Reports
  • Sung Yeop Kim +4
  • PDF
  • Research Article
  • Citations3

Improved PET/MRI accuracy by use of static transmission source in empirically derived hardware attenuation correction

  • Mar 08, 2021
  • EJNMMI Physics
  • Adam Farag +4
  • Research Article

SU‐FF‐T‐406: The Effect of User Definable CT Acquisition Parameters On CT Numbers for Materials of Various Electron Densities

  • Jun 01, 2007
  • Medical Physics
  • A Pevsner +1
  • Research Article
  • Citations107

Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging.

  • Jan 01, 1996
  • Alzheimer Disease & Associated Disorders
  • Claire Labbé +4
  • Research Article

The clinical value of computed tomography Hounsfield unit for diagnosing palpable inguinal lymph node metastasis in patients with penile cancer.

  • Feb 10, 2025
  • Frontiers in oncology
  • Yu Li +4
  • PDF
  • Research Article
  • Citations33

Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

  • Jan 01, 2016
  • BioMed Research International
  • G J Pelgrim +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.