• Home
  • Search
  • Miniaturized Magnetoelastic Sensor System
  • Cite Icon5
  • https://doi.org/10.1109/jsen.2024.3379880Copy DOI Icon

Miniaturized Magnetoelastic Sensor System

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on the Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 0.3 mm in diameter. Up to four sensor bodies can be configured as an evenly spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. The responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient DC biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters. A Raspberry Pi single-board computer and associated software performs data acquisition and controls all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data is then displayed along with a graph of the signal.

Similar Papers
  • Research Article
  • Citations3

The Effect of Ultrasonic Resonance on Impedance in Magnetic Rods

  • Nov 01, 2008
  • IEEE Transactions on Magnetics
  • H Osada +5
  • Research Article
  • Citations10

A novel film eddy current probe having a detection coil interleaved to the excitation coil and the amplified effect by ferromagnetic amorphous alloys particles

  • Nov 01, 2022
  • Sensors and Actuators A: Physical
  • Le Quang Trung +3
  • Research Article
  • Citations7

Design and Performance Research of a New Dual-Excitation Uniform Eddy Current Probe.

  • Nov 16, 2022
  • Sensors
  • Tao Chen +6
  • PDF
  • Research Article
  • Citations1

Design and Analysis of Micro Signal Detection Circuit for Magnetic Field Detection Utilizing Coil Sensors

  • Apr 25, 2024
  • Applied Sciences
  • Qifan Xu +5
  • Research Article
  • Citations6

Field Results of the Electromagnetic Casing Inspection Log

  • Apr 01, 1964
  • Journal of Petroleum Technology
  • J.M Edwards +1
  • Video Transcripts

High spatial resolution flaw detector based on the GMR eddy-current probe

  • Mar 30, 2021
  • Underline Science Inc.
  • Jen-Tzong Jeng +5
  • Research Article
  • Citations10

Burrowing habits of two Arthropods; Odenthobutus doriae and Hemilepistus schirasi in desert of Isfahan, Iran

  • Jan 01, 2017
  • Journal of Entomological Research
  • Rouhullah Dehghani +2
  • Research Article
  • Citations12

Eddy current measurement of crystal axial thermal profiles during Czochralski silicon crystal growth

  • Apr 01, 1988
  • Journal of Crystal Growth
  • K.S Choe +3
  • Research Article
  • Citations24

Development of a flexible alligator forceps: a new instrument for removal of heartworms in the pulmonary arteries of dogs.

  • Jan 01, 1986
  • Nihon juigaku zasshi. The Japanese journal of veterinary science
  • Katsuya Ishihara +2
  • Research Article

A novel modular inner aortic arch stent-graft for localized Stanford type A aortic dissection aneurysm with short healthy proximal ascending aorta

  • May 28, 2022
  • JTCVS Techniques
  • Feng Liu +7
  • Conference Article
  • Citations20

Compact high-speed streak camera for impact-shock study of solids

  • Jan 01, 1993
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tsutomu Mashimo +2
  • Research Article
  • Citations1

Preparation of cylindrical Bi-2223 sintered bulk composed with nickel meshes for current lead

  • Jun 01, 2006
  • Journal of Physics: Conference Series
  • S Yoshizawa +5
  • Research Article
  • Citations2

Bi2212 HTS bulk tubes prepared by the diffusion process for current lead application

  • Sep 01, 2006
  • Fusion Engineering and Design
  • J Ohkubo +4
  • Research Article
  • Citations13

Healing of physeal fracture after fixation with biodegradable self-reinforced polyglycolic acid pins. An experimental study on growing rabbits

  • Jan 01, 1990
  • Clinical Materials
  • E Antero Mäkelä +6
  • Conference Article
  • Citations1

Design of the Detection Probe Based on ACFM

  • Jan 01, 2019
  • Jianyu Li +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.