• Home
  • Search
  • Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters
  • Cite Icon5
  • https://doi.org/10.1364/osac.2.001565Copy DOI Icon

Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters

Show More
  • Abstract
  • Highlights & Summary
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Snapshot imaging polarimeters are used in many different areas. Recently, division of focal plane (DoFP) polarimeters have proved useful as snapshot polarimeters for dynamic applications. For an optimal performance of polarimeters, different works dealing with the error analysis of such devices are proposed in literature. In terms of noise amplification from intensity measurements to the final polarization calculations, well-established quality metrics, as in the condition number or the equally weighted variance criteria, are used. Other studies analyze systematic errors due to deviations in the construction parameters. However, something not considered so far is the effect produced by misalignment between the various pixelated masks over the pixelated structure of the camera sensor, always occurring in experimental implementations of DoFPs. In this work, we study the effect of such misalignments in DoFP polarimeters and demonstrate how they lead to polarimetric systems composed of partially depolarized analyzers. We calculate the combined degree of polarization related to different amounts of misalignment and analyze the corresponding system performance. From this study, we show how an imaging polarimeter based on partially polarized analyzers can still lead to a robust and accurate polarimetric performance, and we also provide the misalignment limits in which an acceptable performance is obtained. We evaluate both the monochromatic and the polychromatic cases with special focus on the latter.

Similar Papers
  • Research Article
  • Citations43

Conditional generative adversarial network demosaicing strategy for division of focal plane polarimeters.

  • Dec 04, 2020
  • Optics express
  • Garrett C Sargent +2
  • Conference Article
  • Citations12

A novel smoothness-based interpolation algorithm for division of focal plane Polarimeters

  • May 01, 2017
  • Jieyun Zhang +5
  • Conference Article
  • Citations1

A New Polarization Image Demosaicking Method in the Frequency Domain for DoFP Polarization Imaging

  • Jul 01, 2020
  • Jinglei Hao +2
  • Research Article
  • Citations3

Reverse Design of Pixel-Type Micro-Polarizer Arrays to Improve Polarization Image Contrast.

  • Oct 12, 2024
  • Micromachines
  • Yonggui Shi +6
  • Research Article
  • Citations50

Assessing effects of exoskeleton misalignment on knee joint load during swing using an instrumented leg simulator

  • Jan 29, 2022
  • Journal of NeuroEngineering and Rehabilitation
  • Jule Bessler-Etten +3
  • Research Article

KYImproving patient care through safety metrics

  • Dec 01, 2013
  • Pharmacy Today
  • Melinda C Joyce
  • Conference Article
  • Citations183

Image quality assessment for iris biometric

  • Apr 17, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nathan D Kalka +3
  • Research Article
  • Citations4

Readmissions after Pancreatic Surgery in Patients with Pancreatic Cancer: Does Hospital Variation Exist for Quality Measurement?

  • Sep 24, 2019
  • Visceral Medicine
  • Ching-Yu Wang +1
  • Research Article
  • Citations3

Summary of United States Human Proteome Organisation (HUPO) Symposium Entitled “Standardized Clinical Proteomics Platforms”

  • May 01, 2009
  • Molecular & Cellular Proteomics
  • Daniel C Liebler
  • Research Article
  • Citations32

Signal detection in turbid water using temporally encoded polarimetric integral imaging.

  • Nov 12, 2020
  • Optics express
  • Rakesh Joshi +3
  • Book Chapter
  • Citations69

A Practical Guide to Model Observers for Visual Detection in Synthetic and Natural Noisy Images

  • Feb 16, 2000
  • Miguel Eckstein +2
  • Conference Article

Adaptive optics imaging technology for extended object based on bilateral filter

  • May 13, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Huizhen Yang +1
  • PDF
  • Research Article
  • Citations30

Polarimetric imaging for cervical pre-cancer screening aided by machine learning: ex vivo studies

  • Jul 06, 2023
  • Journal of Biomedical Optics
  • Demelza Robinson +7
  • Research Article
  • Citations207

Nonlinear Control of a Shape Memory Alloy Actuated Manipulator

  • Sep 20, 2002
  • Journal of Vibration and Acoustics
  • Mohammad H Elahinia +1
  • Research Article

Novel three-axis beam waveguide feed for space-based millimeter-wave applications

  • Jun 01, 1997
  • IEEE Transactions on Antennas and Propagation
  • B Toland +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.