  • Monte Carlo-based diode design for correction-less small field dosimetry
  • Open Access IconOpen Access
  • Cite Icon57
  • https://doi.org/10.1088/0031-9155/58/13/4501Copy DOI Icon

Monte Carlo-based diode design for correction-less small field dosimetry

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Due to their small collecting volume, diodes are commonly used in small field dosimetry. However, the relative sensitivity of a diode increases with decreasing small field size. Conversely, small air gaps have been shown to cause a significant decrease in the sensitivity of a detector as the field size is decreased. Therefore, this study uses Monte Carlo simulations to look at introducing air upstream to diodes such that they measure with a constant sensitivity across all field sizes in small field dosimetry. Varying thicknesses of air were introduced onto the upstream end of two commercial diodes (PTW 60016 photon diode and PTW 60017 electron diode), as well as a theoretical unenclosed silicon chip using field sizes as small as 5 mm × 5 mm. The metric used in this study represents the ratio of the dose to a point of water to the dose to the diode active volume, for a particular field size and location. The optimal thickness of air required to provide a constant sensitivity across all small field sizes was found by plotting as a function of introduced air gap size for various field sizes, and finding the intersection point of these plots. That is, the point at which was constant for all field sizes was found. The optimal thickness of air was calculated to be 3.3, 1.15 and 0.10 mm for the photon diode, electron diode and unenclosed silicon chip, respectively. The variation in these results was due to the different design of each detector. When calculated with the new diode design incorporating the upstream air gap, was equal to unity to within statistical uncertainty (0.5%) for all three diodes. Cross-axis profile measurements were also improved with the new detector design. The upstream air gap could be implanted on the commercial diodes via a cap consisting of the air cavity surrounded by water equivalent material. The results for the unclosed silicon chip show that an ideal small field dosimetry diode could be created by using a silicon chip with a small amount of air above it.

Similar Papers
  • Research Article
  • Citations44

The effect of very small air gaps on small field dosimetry

  • Oct 09, 2012
  • Physics in Medicine and Biology
  • P H Charles +10
  • Research Article
  • Citations18

Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.

  • Oct 01, 2014
  • Medical physics
  • P H Charles +9
  • Research Article
  • Citations9

Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields

  • Jan 01, 2016
  • Internatuinal Journal of Radiation Research
  • W Parwaie +5
  • PDF
  • Research Article
  • Citations38

Mass-density compensation can improve the performance of a range of different detectors under non-equilibrium conditions

  • Nov 11, 2013
  • Physics in Medicine and Biology
  • T S A Underwood +3
  • Abstract
  • Citations1

Measurement, modelling and reporting of small field output factors requires systematic approaches for accurate dosimetry

  • Jan 01, 2014
  • Physica Medica
  • D.I Thwaites +3
  • Research Article
  • Citations1

TH‐EF‐204‐02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

  • Jun 01, 2016
  • Medical Physics
  • J Seuntjens
  • Research Article
  • Citations1

Comparison of Air-Gaps Effect in a Small Cavity on Dose Calculation for 6 MV Linac.

  • Feb 01, 2021
  • Journal of biomedical physics & engineering
  • A Azzi
  • Research Article
  • Citations7

Investigation of 2D radiophotoluminescence films in radiotherapy: Multileaf collimator Quality Assurance and small field dosimetry

  • Jan 25, 2022
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Luana De Freitas Nascimento +5
  • Research Article
  • Citations4

SU‐EE‐A2‐02: Present Status of IAEA/AAPM Recommendations on Small and Composite Field Dosimetry

  • Jun 01, 2010
  • Medical Physics
  • R Alfonso +12
  • Research Article

SU‐E‐T‐471: Small Field Jaw/MLC Reference Data

  • May 29, 2014
  • Medical Physics
  • J Kerns +6
  • Research Article
  • Citations109

Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy

  • Apr 19, 2000
  • Radiation Measurements
  • Martin J Butson +3
  • Research Article
  • Citations4

Characterisation of small photon field outputs in a heterogeneous medium using X-ray voxel Monte Carlo dose calculation algorithm

  • Aug 23, 2017
  • Journal of Radiotherapy in Practice
  • Karthikeyan Nithiyanantham +6
  • Research Article

Explicit Constructions of Capacity-Achieving T-PIR Schemes Over Small Fields via Generalized Minor Matrices

  • Jul 01, 2025
  • IEEE Transactions on Information Theory
  • Jingke Xu +1
  • Research Article

SU-E-T-552: Dosimetry Investigation of a PinPoint Ion Chamber for SRS Commissioning and Treatment Verification

  • Jun 01, 2011
  • Medical Physics
  • L Jin +4
  • Research Article

SU‐F‐T‐445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

  • Jun 01, 2016
  • Medical Physics
  • I Das +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.