• Home
  • Search
  • Motion detection system for AXAF x-ray ground testing
  • Cite Icon1
  • https://doi.org/10.1117/12.140594Copy DOI Icon

Motion detection system for AXAF x-ray ground testing

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The concept, implementation, and performance of the motion detection system (MDS) designed as a diagnostic for X-ray ground testing for AXAF are described. The purpose of the MDS is to measure the magnitude of a relative rigid body motion among the AXAF test optic, the X-ray source, and X-ray focal plane detector. The MDS consists of a point source, lens, centroid detector, transimpedance amplifier, and computer system. Measurement of the centroid position of the image of the optical point source provides a direct measure of the motions of the X-ray optical system. The outputs from the detector and filter/amplifier are digitized and processed using the calibration with a 50 Hz bandwidth to give the centroid's location on the detector. Resolution of 0.008 arcsec has been achieved by this system. Data illustrating the performance of the motion detection system are also presented.

Similar Papers
  • Research Article
  • Citations13

Detection performance of security system using radio waves based on space-time signal processing

  • Jan 01, 2010
  • Procedia - Social and Behavioral Sciences
  • Shun Kawakami +2
  • Conference Article

A simplified geometric calibration method for rotating triple head pinhole SPECT system using point source

  • Jan 01, 2007
  • Joong Hyun Kim +5
  • Research Article
  • Citations64

A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms.

  • Nov 12, 2010
  • Medical Physics
  • Subok Park +4
  • Research Article
  • Citations7

Point-source localization in blurred images by a frequency-domain eigenvector-based method

  • Jan 01, 1995
  • IEEE Transactions on Image Processing
  • M Gunsay +1
  • Conference Article

Design and performance of the pre-fire detection system for the FRX-L main capacitor

  • Jun 15, 2003
  • W.J Waganaar +6
  • Research Article
  • Citations11

Transformable Reflective Telescope for optical testing and education

  • Jun 17, 2020
  • Applied Optics
  • Woojin Park +8
  • Research Article
  • Citations64

Determination of both mechanical and electronic shifts in cone beam SPECT

  • Jun 01, 1993
  • Physics in Medicine & Biology
  • Jianying Li +4
  • Research Article
  • Citations1

Motion Boundary Detection Improved by Bio-Inspired Approach

  • Oct 31, 2019
  • International Journal on Communications Antenna and Propagation (IRECAP)
  • Hayat Yedjour +2
  • Research Article
  • Citations30

Pushing the limits of the coronagraphic occulters on Hubble Space Telescope/Space Telescope Imaging Spectrograph

  • Jun 13, 2019
  • Journal of Astronomical Telescopes, Instruments, and Systems
  • John H Debes +2
  • Conference Article
  • Citations3

Evaluation of the image quality of telescopes using the star test

  • Sep 28, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Sergio Vazquez Y Monteil +2
  • Research Article
  • Citations2

A Multimodal Transfer Learning Method for Classifying Images of Celestial Point Sources

  • Oct 01, 2023
  • Publications of the Astronomical Society of the Pacific
  • Bingjun Wang +5
  • Research Article
  • Citations4

Atmospheric Methane Retrieval Based on Back Propagation Neural Network and Simulated AVIRIS-NG Data

  • Jan 01, 2024
  • IEEE Geoscience and Remote Sensing Letters
  • Yunxia Huang +4
  • Research Article
  • Citations30

Novel outline features for pedestrian detection system with thermal images

  • May 09, 2015
  • Pattern Recognition
  • Chun-Fu Lin +5
  • Research Article
  • Citations10

Optimization of energy window limits for photopeak detection systems

  • Jan 01, 1994
  • Applied Radiation and Isotopes
  • Bradley M Palmer +1
  • Research Article

A-257 Revolutionizing Fungal Infection Diagnosis: A Sensitive, Cost-Effective, and Time-Efficient Solution

  • Oct 02, 2024
  • Clinical Chemistry
  • K Ramakrishnan +10
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.