• Home
  • Search
  • MRSCloud: a Cloud-based MR Spectroscopy Tool for Basis Set Simulation
  • Cite Icon5
  • https://doi.org/10.1101/2022.03.22.485310Copy DOI Icon

MRSCloud: a Cloud-based MR Spectroscopy Tool for Basis Set Simulation

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Abstract Background Accurate quantification of in vivo proton magnetic resonance spectra involves modeling with a linear combination of known metabolite basis functions. Basis sets can be generated by numerical simulation using the quantum mechanical density-matrix formalism. Accurate simulations for a basis set require correct sequence timings, and pulse shapes and durations. Purpose To present a cloud-based spectral simulation tool ‘MRSCloud’. It allows community users of MRS to simulate a vendor- and sequence-specific basis set online in a convenient and timeefficient manner. This tool can simulate basis sets for 3 major MR scanner vendors (GE, Philips, Siemens), including conventional acquisitions and spectral editing schemes (MEGA, HERMES, HERCULES) with PRESS and semi-LASER localization. Study Type Prospective. Specimen N/A Field Strength/Sequence Simulations of 3T basis sets for conventional and spectral-editing sequences (MEGA, HERMES, HERCULES) with PRESS and sLASER localizations. Assessment Simulated metabolite basis functions generated by MRSCloud are compared to those generated by FID-A and MARSS, and a phantom-acquired basis-set from LCModel. Statistical Tests Intraclass correlation coefficients (ICC) were calculated to measure the agreement between individual metabolite basis functions generated using different packages. Statistical analysis was performed using R in RStudio. Results Simulation time for a full basis set is approximately 1 hour. ICCs between MRSCloud and FID-A were at least 0.98 and ICCs between MRSCloud and MARSS were at least 0.96. ICCs between simulated MRSCloud basis spectra and acquired LCModel basis spectra were lowest for Gln at 0.68 and highest for NAA at 0.96. Data Conclusion Substantial reductions in runtime have been achieved by implementing the 1D projection method, coherence-order filtering, and pre-calculation of propagators. High ICC values indicated that the accelerating features are running correctly and produce comparable and accurate basis sets. The generated basis set has been successfully used with LCModel.

Similar Papers
  • Research Article
  • Citations2

Evaluation of the International Spinal Cord Injury Bowel Function Basic Data Set Version 2.0 in Children and Youth With Spinal Cord Injury.

  • Oct 25, 2021
  • Topics in spinal cord injury rehabilitation
  • Kathryn Dent +8
  • Research Article

Effect of maturity status on lower-limb strength testing reliability in academy football players from an elite professional club

  • Jan 27, 2025
  • Current Issues in Sport Science (CISS)
  • Maxime Violin +3
  • Research Article
  • Citations22

CHOROIDAL NEOVASCULAR AREA AND VESSEL DENSITY COMPARISON BETWEEN TWO SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY DEVICES

  • Mar 01, 2020
  • Retina
  • Avi Ohayon +5
  • Research Article
  • Citations1

Evaluating the reproducibility and validity of maximal mouth opening measurement techniques

  • Oct 01, 2024
  • Journal of Stomatology oral and Maxillofacial Surgery
  • Maximiliaan Smeets +6
  • Research Article
  • Citations5

Reliability and characterisation of the 20-maximum trampoline jump test

  • May 01, 2021
  • Isokinetics and Exercise Science
  • Natalie Dyas +3
  • Research Article
  • Citations21

Reliability of gait variability assessment in older individuals during a six-minute walk test

  • Oct 20, 2015
  • Journal of Biomechanics
  • Eleni Grimpampi +5
  • Research Article
  • Citations22

The Reliability of the Associate Platinum Digital Foot Scanner in Measuring Previously Developed Footprint Characteristics: A Technical Note

  • Feb 01, 2011
  • Journal of Manipulative and Physiological Therapeutics
  • M Owen Papuga +1
  • Research Article

Ultrasonic cleaning equipment

  • Aug 01, 1995
  • Metal Finishing
  • Book Chapter

Influence of Scan Duration on the Reliability of Resting-State fMRI Regional Homogeneity

  • Jan 01, 2014
  • Xiaotang Li +2
  • Research Article

Technical and functional validations of High Angular Resolution Diffusion Imaging (HARDI)-MR tractography in paediatric epilepsy patients

  • Jan 01, 2013
  • Frontiers in Human Neuroscience
  • Barton Sarah +7
  • Research Article
  • Citations74

Validity and reliability of the Turkish translation of the Pediatric Evaluation of Disability Inventory (PEDI)

  • Jan 01, 2007
  • Disability and Rehabilitation
  • Gulten Erki˙N +4
  • Research Article
  • Citations10

Reliability and Reproducibility of Manual and Automated Volumetric Measurements of Periapical Lesions

  • Jul 31, 2015
  • Journal of Endodontics
  • Eduardo Massaharu Aoki +4
  • PDF
  • Research Article
  • Citations1

Test-Retest Intra-Session Reliability of Isokinetic Knee Strength Measurements in Obese Children

  • Aug 26, 2020
  • Applied Sciences
  • Daniel Collado-Mateo +6
  • Research Article
  • Citations54

Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects

  • Feb 21, 2019
  • British Journal of Ophthalmology
  • Danqi Fang +4
  • Research Article
  • Citations166

Accurate relativistic Gaussian basis sets for H through Lr determined by atomic self-consistent field calculations with the third-order Douglas–Kroll approximation

  • Sep 08, 2001
  • The Journal of Chemical Physics
  • Takashi Tsuchiya +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.