• Home
  • Search
  • Multi objective bacterial foraging optimization algorithm for power factor correction using interleaved DC-DC SEPIC converter
  • Cite Icon4
  • https://doi.org/10.1109/tima.2017.8064781Copy DOI Icon

Multi objective bacterial foraging optimization algorithm for power factor correction using interleaved DC-DC SEPIC converter

  • Jan 1, 2017
  • C Komathi +1 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Power Factor Correction (PFC) is inherently required in Switched Mode Power Supplies (SMPS) to correct the poor power factor caused by nonlinearities introduced by the switching devices. This paper proposes Bacterial Foraging Optimization (BFO) algorithm to obtain the optimal Proportional Integral (PI) controller parameters for Interleaved DC-DC Single Ended Primary Inductance Converter (SEPIC) based Power Factor Correction (PFC). In this paper, conventional PI controller parameters are obtained using frequency domain approach. In order to improve the dynamic performance in terms of minimum rise time, minimum settling time, minimum peak overshoot, minimum % Total Harmonic Distortion (THD), maximum % efficiency, and power factor close to unity, BFO algorithm with weights attached for various error criterion such as Integral Square Error (ISE), Integral Absolute Error (IAE), Integral Time Square Error (ITSE) and Integral Time Absolute Error (ITAE) is used as weighted sum multi objective fitness function to find the best optimal PI controller parameters for Interleaved DC-DC SEPIC PFC converter. Simulation results using Matlab/ Simulink software illustrate the reduction in overshoot, settling time, rise time, %THD, increase in % efficiency and power factor close to unity for multi objective BFO based PI controller over conventional PI controller. The proposed scheme can also produce an improved dynamic performance for variation in load, line and reference voltage.

Similar Papers
  • PDF
  • Research Article
  • Citations6

Servo and Regulatory Response of an Industrial Fluid Catalytic Cracking (FCC) Unit under Fuzzy Logic Supervisory Control

  • Sep 01, 2023
  • Engineering and Technology Journal
  • Princewill Josiah +2
  • PDF
  • Research Article
  • Citations1

Synthesis and Soft Implementation of Supervisory Control Scheme in an Industrial Fluid Catalytic Cracking (FCC) Unit of a Nigerian Refinery

  • Jan 15, 2023
  • Global Journal of Pure and Applied Chemistry Research
  • P.N Josiah +3
  • Conference Article
  • Citations9

Fuzzy Logic Control for a Stand-Alone PV System with PI Controller for Battery Charging Based on Evolutionary Technique

  • Sep 01, 2019
  • Omnia S S Hussian +2
  • Research Article

Analysis of Error Integral Performance Indexes in Grid Connected Photovoltaic System through PI Controller for Improving DC Link Voltage by Metaheuristic and Direct Search Methods

  • May 15, 2025
  • International Energy Journal
  • Amit Verma +2
  • Book Chapter

Modified Design Approach Using Cuckoo Search Optimization Algorithm for Mitigation of Harmonics and Improvement of Efficiency in Back Light LED TV Power Supply

  • Jan 01, 2020
  • C Komathi +1
  • PDF
  • Research Article
  • Citations41

Modern PID/FOPID controllers for frequency regulation of interconnected power system by considering different cost functions

  • Aug 28, 2023
  • Scientific Reports
  • Mohamed Ahmed Ebrahim Mohamed +2
  • PDF
  • Research Article
  • Citations15

Compatibility of objective functions with simplex algorithm for controller tuning of HVDC system

  • Feb 13, 2020
  • Ingeniería e Investigación
  • Haaris Rasool +5
  • PDF
  • Research Article
  • Citations7

Hybrid fuzzy logic–PI control with metaheuristic optimization for enhanced performance of high-penetration grid-connected PV systems

  • Jul 09, 2025
  • Scientific Reports
  • Mohamed Ahmed Ebrahim Mohamed +3
  • Research Article
  • Citations6

A robust PIλDµ controller for enhancing the width of the molten pool and the tracking of welding current in gas metal arc welding (GMAW) processes

  • Aug 04, 2023
  • International Journal of Modelling and Simulation
  • Noureddine Hamouda +3
  • Conference Article
  • Citations12

Performance Analysis of Model Predictive Control for Cascaded Tank Level Control System

  • Dec 10, 2021
  • Bhawesh Prasad +2
  • Research Article
  • Citations10

Optimized Neuro-Adaptive Third-Order Sliding Mode Control With High-Gain Differentiator for Enhanced Photovoltaic System Performance: Simulation and Experimental Validation

  • Oct 01, 2025
  • IEEE Journal of Emerging and Selected Topics in Power Electronics
  • Ameen Ullah +4
  • Research Article
  • Citations13

Optimization of PI-Cascaded Controller’s Parameters for Linear Servo Mechanism: A Comparative Study of Multiple Algorithms

  • Jan 01, 2023
  • IEEE Access
  • M Abdelbar +6
  • Research Article
  • Citations2

Comparison of the Performance of Type-1 and Interval Type-2 Fuzzy PI Controllers for Liquid Level Control in a Coupled Tank System

  • Aug 31, 2024
  • Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
  • Hatice Nursoy +1
  • Research Article
  • Citations52

Performance evaluation of objective functions in automatic generation control of thermal power system using ant colony optimization technique-designed proportional–integral–derivative controller

  • May 16, 2017
  • Electrical Engineering
  • K Jagatheesan +4
  • Conference Article
  • Citations3

Enhancing the Width of Molten Pool and the Tracking of Welding Current in Gas Metal Arc Welding Processes Using a Robust PIλDμ Controller

  • Nov 26, 2022
  • Noureddine Hamouda +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.