• Home
  • Search
  • Multi-Scale Deconvolution of Mass Spectrometry Signals
  • Cite Icon1
  • https://doi.org/10.5772/37772Copy DOI Icon

Multi-Scale Deconvolution of Mass Spectrometry Signals

  • Apr 4, 2012
  • Mhamed Boulakroune +1 more
Show More
  • Abstract
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

It has become more important to measure accurate depth profiles in developing more advanced devices. To this aim, Depth profiling in secondary ion mass spectrometry (SIMS) has been extensively used as an informative technique in the semiconductor and electronic devices fields due to its high sensitivity, quantification accuracy and depth resolution (Fujiyama et al, 2011; Seki et al, 2011). However, the depth resolution in SIMS analysis is still limited to provide reliable and precise information in very thin structures such as delta layers, abrupt interfaces, etc. By optimization of the experimental conditions, the depth resolution can be enhanced. In particular, lowering the primary energy seems to be a good solution, but this increases the measurement time and leads to other limitations, owing to the wrong focalization of primary ion beam, such as roughness in the crater bottom, not flat crater, etc. Therefore, the depth resolution remains so far to its perfect limit. It is only by numerical processing like deconvolution that the depth resolution can be improved beyond its experimental limits.

Loading PDF

Similar Papers
  • Research Article
  • Citations61

Transient phenomena and impurity relocation in SIMS depth profiling using oxygen bombardment: pursuing the physics to interpret the data

  • Nov 15, 1996
  • Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
  • Klaus Wittmaack
  • Research Article
  • Citations1

Ion Etching Effects Occurring in Secondary Ion Mass Spectrometry Depth profiling of InGaAs/InP and InGaAs/AlAs/InP MBE Grown Heterostructures

  • Nov 01, 1996
  • Acta Physica Polonica A
  • A.V Kozhukhov +2
  • Research Article
  • Citations40

Challenges of biological sample preparation for SIMS imaging of elements and molecules at subcellular resolution

  • May 08, 2008
  • Applied Surface Science
  • Subhash Chandra
  • Research Article
  • Citations18

Noise,resolution and entropy in sputter profiling

  • Nov 15, 1996
  • Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
  • Mitch Dowsett +1
  • Conference Article

Effects of cleaning techniques on residual contamination in SIMOX

  • Oct 01, 1991
  • M.J Anc +4
  • Research Article
  • Citations7

Critical need and future directions of SIMS depth profiling in CMOS fabrication

  • Jan 29, 2018
  • Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena
  • Paul A W Van Der Heide
  • Book Chapter
  • Citations6

Chemical Microscopy of Biological Samples by Dynamic Mode Secondary Ion Mass Spectrometry (SIMS)

  • Jan 01, 2009
  • Gradimir N Misevic +9
  • Research Article
  • Citations9

Quantification of Liquid Crystal Concentrations in Periodically Stratified Polymer-Dispersed Liquid Crystal Films by Dynamic Secondary Ion Mass Spectrometry and Multivariate Statistical Analysis

  • Jun 28, 2007
  • The Journal of Physical Chemistry C
  • B K C Kjellander +5
  • Conference Article
  • Citations3

Sputter rate change and surface roughening during oblique and normal incidence O/sub 2//sup +/ bombardment of silicon, with and without oxygen flooding

  • Jan 01, 1999
  • C.W Magee +4
  • Research Article
  • Citations38

Pyroxene standards for SIMS oxygen isotope analysis and their application to Merapi volcano, Sunda arc, Indonesia

  • Oct 11, 2016
  • Chemical Geology
  • Frances M Deegan +6
  • Book Chapter
  • Citations10

Understanding of Corrosion Mechanisms after Irradiation: Effect of Ion Irradiation of the Oxide Layers on the Corrosion Rate of M5

  • Jan 01, 2018
  • Marc Tupin +11
  • Research Article
  • Citations6

Loss of depth resolution with depth in secondary ion mass spectrometry (SIMS) due to variations in ion dose density across the rastered area

  • Nov 01, 1986
  • Vacuum
  • Ds Mcphail +2
  • Conference Article
  • Citations9

A review of SIMS techniques for characterization of ultra low energy ion implants

  • Jun 16, 1996
  • S.P Smith +3
  • Research Article

III-V Semiconductors

  • Jan 01, 1986
  • Hyomen Kagaku
  • Shunsuke Kurosawa +1
  • Research Article
  • Citations36

Variation of yield with thickness in SIMS and PDMS: Measurements of secondary ion emission from organized molecular films

  • Feb 01, 1988
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
  • G Bolbach +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.