• Home
  • Search
  • Multichannel applications of double relaxation oscillation SQUIDs
  • Cite Icon6
  • https://doi.org/10.1088/0953-2048/14/12/308Copy DOI Icon

Multichannel applications of double relaxation oscillation SQUIDs

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Double relaxation oscillation SQUIDs (DROSs) provided high flux-to-voltage transfers of larger than 1 mV Φ0−1 and simple flux-locked loop circuits were used for SQUID operation. We constructed two multichannel systems based on DROSs. The first system is a 40-channel planar gradiometer system consisting of integrated first-order pickup coils. average noise level of the 40 channels is 1 fT cm−1 Hz−1/2 at 100 Hz, corresponding to a field noise of 4 fT Hz−1/2, operating inside a magnetically shielded room. The second one is a 37-channel magnetometer system with 37 integrated magnetometers distributed on a spherical surface and measures field component normal to the head surface. The average noise of the magnetometers is 3 fT Hz−1/2 at 100 Hz. The two systems were applied to measure neuromagnetic fields.

Similar Papers
  • Research Article
  • Citations3

Comparison of Double Relaxation Oscillation SQUIDs and DC-SQUIDs of Large Stewart-McCumber Parameter

  • Aug 01, 2023
  • IEEE Transactions on Applied Superconductivity
  • Bokyung Kim +3
  • Research Article
  • Citations1

Flux to voltage transfer function and noise in double relaxation oscillation SQUIDs

  • Jun 01, 1997
  • IEEE Transactions on Appiled Superconductivity
  • Genghua Chen +2
  • Research Article
  • Citations6

Low-noise SQUIDs with large transfer: two-stage SQUIDs based on DROSs

  • Mar 12, 2002
  • Physica C: Superconductivity
  • M Podt +2
  • Research Article
  • Citations9

Compact Readout Electronics for 62-Channel DROS Magnetocardiogram System

  • Jun 01, 2005
  • IEEE Transactions on Appiled Superconductivity
  • J.-M Kim +5
  • Research Article
  • Citations3

Development of a SQUID Readout System for the MiniGRAIL

  • Jun 01, 2005
  • IEEE Transactions on Appiled Superconductivity
  • M Podt +4
  • Dissertation
  • Citations3

Second Generation dc SQUID Magnetometers: (Double) Relaxation Oscillation SQUIDs

  • Sep 23, 1993
  • Derk Jan Adelerhof
  • Book Chapter
  • Citations14

Monte-Carlo Simulation of Ultrasonic Grain Noise

  • Jan 01, 1993
  • Review of Progress in Quantitative Nondestructive Evaluation
  • I Yalda-Mooshabad +2
  • Research Article
  • Citations10

Application of the double relaxation oscillation superconducting quantum interference device sensor to micro-tesla 1H nuclear magnetic resonance experiments

  • Sep 01, 2011
  • Journal of Applied Physics
  • Chan Seok Kang +8
  • Research Article
  • Citations15

Design of Digital DROS With SFQ Up/Down Counter for Wide Dynamic Operation Range

  • Jun 01, 2011
  • IEEE Transactions on Applied Superconductivity
  • Hiroaki Myoren +3
  • Research Article
  • Citations4

Acoustics in South African classrooms: Regulations versus reality

  • Aug 13, 2021
  • Building Acoustics
  • Coralie Van Reenen +1
  • Conference Article
  • Citations2

Fast calculation of computer-generated spherical hologram by spherical harmonic transform

  • May 15, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Y Sando +3
  • Research Article
  • Citations11

The Status of Noise Pollution in the Major Traffic Intersections of Khulna Metropolitan City in Bangladesh and its Possible Effect on Noise-Exposed People

  • Sep 14, 2020
  • European Journal of Environment and Earth Sciences
  • Aliza Sultana +2
  • Research Article
  • Citations79

Road traffic noise in southern Sweden and its relation to annoyance, disturbance of daily activities and health

  • Oct 01, 2006
  • Scandinavian Journal of Work, Environment & Health
  • Jonas Björk +5
  • Research Article

Traffic-Noise Assessment at Rush Hours in Quetta City

  • Jun 25, 2020
  • Journal of Applied and Emerging Sciences
  • Anila Ali +4
  • PDF
  • Research Article
  • Citations3

Measurement of hazardous personal noise exposure in spice manufacturing industry

  • Jan 01, 2019
  • Journal of Physics: Conference Series
  • P Alagapan +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.