• Home
  • Search
  • Multiphoton parallel transmission (MP-pTx): Pulse design methods and numerical validation.
  • Open Access IconOpen Access
  • Cite Icon1
  • https://doi.org/10.1002/mrm.30116Copy DOI Icon

Multiphoton parallel transmission (MP-pTx): Pulse design methods and numerical validation.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We propose and evaluate multiphoton parallel transmission (MP-pTx) to mitigate flip angle inhomogeneities in high-field MRI. MP-pTx is an excitation method that utilizes a single, conventional birdcage coil supplemented with low-frequency (kHz) irradiation from a multichannel shim array and/or gradient channels. SAR analysis is simplified to that of a conventional birdcage coil, because only the radiofrequency (RF) field from the birdcage coil produces significant SAR. MP-pTx employs an off-resonance RF pulse from a conventional birdcage coil supplemented with oscillating -directed fields from a multichannel shim array and/or the gradient coils. We simulate the ability of MP-pTx to create uniform nonselective brain excitations at 7 T using realistic and field maps. The RF, shim array, and gradient waveform's amplitudes and phases are optimized using a genetic algorithm followed by sequential quadratic programming. A 1 ms MP-pTx excitation using a 32-channel shim array with current constrained to less than 50 Amp-turns reduced the transverse magnetization's normalized root-mean-squared error from 29% for a conventional birdcage excitation to 6.6% and was nearly 40% better than a 1 ms birdcage coil 5 kT-point excitation with optimized kT-point locations and comparable pulse power. The MP-pTx method resembles conventional pTx in its goals and approach but replaces the parallel RF channels with cheaper, low-frequency shim channels. The method mitigates high-field flip angle inhomogeneities to a level better than 3 T CP-mode and comparable to 7 T pTx while retaining the straightforward SAR characteristics of conventional birdcage excitations, as low-frequency shim array fields produce negligible SAR.

Similar Papers
  • Research Article
  • Citations5

Multi-port-driven birdcage coil for multiple-mouse MR imaging at 7 T.

  • May 10, 2016
  • Scanning
  • Phil Heo +6
  • Research Article
  • Citations12

Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI.

  • Jan 31, 2019
  • Medical Image Analysis
  • Seungbin Ko +4
  • PDF
  • Research Article
  • Citations66

Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging

  • Aug 03, 2015
  • PLoS ONE
  • Clare E Mcelcheran +4
  • Research Article
  • Citations5

Design and Analysis of Microstrip-Based RF Birdcage Coil for 1.5 T Magnetic Resonance Imaging

  • Feb 13, 2014
  • Applied Magnetic Resonance
  • Krishnan Thiyagarajan +2
  • Research Article
  • Citations8

Design and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T

  • Dec 16, 2013
  • IOP Conference Series: Materials Science and Engineering
  • Bernat Palau Tomas +2
  • Research Article
  • Citations15

Multiband RF pulse design for realistic gradient performance

  • Sep 14, 2018
  • Magnetic Resonance in Medicine
  • Samy Abo Seada +4
  • Conference Article
  • Citations1

Calculation of SAR and B/sub 1/-field within human head excited by MRI birdcage coils

  • Jul 13, 1997
  • J Chen +1
  • Research Article

Radiofrequency-transparent local B0 shimming coils using float traps.

  • Nov 04, 2024
  • Magnetic resonance in medicine
  • Changzhe Liu +5
  • Conference Article

Safe Imaging at 3 Tesla for Children with Deep Brain Electrodes: A simulation Study of a Double-Row Parallel Transmit Coil Array

  • Sep 16, 2025
  • Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
  • Nejat Karadeniz +3
  • Research Article
  • Citations35

Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils.

  • Jan 22, 2003
  • Magnetic Resonance in Medicine
  • Marcello Alecci +5
  • Research Article
  • Citations49

MRI Coil Design Using Boundary-Element Method With Regularization Technique: A Numerical Calculation Study

  • Apr 01, 2010
  • IEEE Transactions on Magnetics
  • Guofa Shou +5
  • Research Article
  • Citations1

The modular (twin) gradient coil—high resolution, high contrast, diffusion weighted EPI at 1.0 Tesla

  • Feb 01, 1999
  • Magnetic Resonance Materials in Physics, Biology & Medicine
  • Paul R Harvey
  • Research Article
  • Citations15

Joint Design of RF and Gradient Waveforms via Auto-differentiation for 3D Tailored Excitation in MRI.

  • May 24, 2021
  • IEEE Transactions on Medical Imaging
  • Tianrui Luo +3
  • Research Article
  • Citations8

A cradle-shaped gradient coil to expand the clear-bore width of an animal MRI scanner

  • Dec 21, 2009
  • Physics in Medicine & Biology
  • K M Gilbert +3
  • Research Article
  • Citations6

Multimodal surface coils for low field MR imaging

  • Jul 04, 2024
  • Magnetic Resonance Imaging
  • Yunkun Zhao +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.