• Home
  • Search
  • Multiple AI based Controlling Techniques for Power Filter Output Quality Improvement
  • https://doi.org/10.24113/ijoscience.v7i1.342Copy DOI Icon

Multiple AI based Controlling Techniques for Power Filter Output Quality Improvement

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Similar Papers
Abstract

The excessive of power electronics devices in distribution system has evolved the problem of power quality. This work represents the effective solution of shunt active power filter for eliminating the harmonics to maintain the quality of utility power supply. In the proposed scheme shunt active filter acts as a voltage source and eliminates harmonics by injecting equal but opposite harmonics components at the point of common coupling. Simulation of shunt active filter based on instantaneous reactive has been achieved in the MATLAB/SIMULINK environment. The controllers are being designed with the objective of reducing the THD% in voltage and current available at the nonlinear load terminal of the system. The controller incorporated optimization algorithms based on the artificial intelligence techniques as well. The comparative analysis of the effectiveness and efficiency of the controllers in improving the quality factors has been carried out. The distortion level in the output voltage waveforms in both the cases being fed to the load when compared, it is found that proposed hybrid structure of control for the filter is more effective in reducing the distortion as compared to standard PQ theory based architecture. The study concluded that the total harmonic distortion in the voltage output waveform being fed to the load using only PQ theory based online learning algorithm is found to be 1.59 % while in case of the output voltage at the load terminal from the power filter using proposed hybrid algorithm comprising of NN learning with CSA optimizing control and PQ_RLS algorithm for THD reduction the THD% level is 0.43 %.

Loading PDF

Similar Papers
  • Research Article
  • Citations39

Compensation Characteristics of Shunt Active and Series Active Power Filters.

  • Jan 01, 1993
  • IEEJ Transactions on Industry Applications
  • F.Z Peng +2
  • Conference Article
  • Citations5

Predictive Control of Seven Level Multi-level Inverter Based Single Phase Shunt Active Filter

  • Oct 09, 2022
  • Parth Patel +4
  • Book Chapter
  • Citations3

Photovoltaic Cell with Shunt Active Power Filter for Harmonic Cancelation Using Modified PSO-Based PI Controller

  • Jan 01, 2020
  • Amba Subhadarshini Nayak +2
  • Conference Article
  • Citations12

Takagi-sugeno (TS)-type fuzzy logic controller for three-phase four-wire shunt active power filter for unbalanced load

  • Nov 01, 2016
  • Harsha Vanjani +3
  • Research Article
  • Citations4

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

  • Jan 01, 2014
  • IOSR Journal of Electrical and Electronics Engineering
  • M Ramya +3
  • Research Article
  • Citations11

Current Control of the Isolated Self-Excited Induction Generator using Shunt Active Filter

  • Jan 01, 2012
  • Energy Procedia
  • A.M Bouzid +5
  • PDF
  • Research Article
  • Citations2

Network current quality enhancement under nonlinear and unbalanced load conditions using a four-wire inverter-based active shunt filter

  • Aug 31, 2021
  • Indonesian Journal of Electrical Engineering and Informatics (IJEEI)
  • Karim Belalia +4
  • Research Article

Harmonic Compensation Using Shunt Active Power Filter In Power System Using Matlab

  • Mar 27, 2013
  • International Journal of Scientific Engineering and Research
  • Neha Kumari Isha
  • Conference Article
  • Citations89

Modeling and nonlinear control of shunt active power filter in the synchronous reference frame

  • Oct 01, 2000
  • N Mendalek +1
  • Research Article

Adaptive filter based current controller for Shunt Active filter

  • Apr 25, 2018
  • International Journal of Engineering & Technology
  • R Sriranjani +1
  • Research Article
  • Citations49

FLC based shunt active filter (p–q and Id–Iq) control strategies for mitigation of harmonics with different fuzzy MFs using MATLAB and real-time digital simulator

  • Dec 12, 2012
  • International Journal of Electrical Power & Energy Systems
  • Anup Kumar Panda +1
  • Research Article
  • Citations527

Three-phase four-wire shunt active filter control strategies

  • Mar 01, 1997
  • IEEE Transactions on Power Electronics
  • M Aredes +2
  • Conference Article
  • Citations8

A Novel Shunt Hybrid Power Filter for the Mitigation of Power System Harmonics

  • Oct 01, 2007
  • Ab Hamadi +3
  • Conference Article
  • Citations28

Active power filter for harmonic mitigation in a distributed power generation system

  • Apr 01, 2017
  • 2017 Innovations in Power and Advanced Computing Technologies (i-PACT)
  • Ritesh Dash +2
  • Conference Article
  • Citations10

Performance evaluation of Shunt Active Harmonic filter under different control techniques

  • Mar 01, 2015
  • S Parthasarathy +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.