• Home
  • Search
  • Myopia correction in children: a meta-analysis.
  • Cite Icon9
  • https://doi.org/10.25011/cim.v40i3.28391Copy DOI Icon

Myopia correction in children: a meta-analysis.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The purpose of this study was to conduct a meta-analysis comparing rigid gas permeable lenses (RGP) with soft contact lenses (SCL), spectacles and orthokeratology (OK) lenses for myopia control with respect to axial length elongation, spherical equivalent and measures of corneal curvature. Medline, Cochrane, EMBASE, and Google Scholar databases were searched to September 29, 2015 using the following keywords: rigid gas permeable contact lens; refractive error; and refractive abnormalities. Randomized controlled trials, two-arm prospective studies and retrospective studies of children with myopia treated with RGP lenses compared with spectacles, SCL, and OK lenses were included. Outcome measures were changes of axial length, spherical equivalent, flatter meridian, steeper meridian and corneal apical radius. Five studies were included. Three studies reported axial length change after 2-3 years of treatment with RGP lenses and SCL/spectacles and no difference between the groups was noted (pooled mean difference = -0.077, 95% confidence interval [CI]: -0.120 to 0.097, p = 0.840). Two studies reported a change of spherical equivalent after 2-3 years of treatment with RGP lenses and SCL/spectacles, and no difference between the groups was noted (pooled mean difference = 0.275, 95% CI: -0.390 to 0.941, p = 0.417). Two studies compared corneal curvature measures between RGP and OK lenses after 3-6 months of treatment and no differences in any measures of corneal curvature were seen. The effect of RGP lenses and SCL/spectacles on axial length elongation and spherical equivalent and of RGP and OK lenses on corneal curvature in children with myopia was similar.

Similar Papers
  • Research Article
  • Citations8

Visual performance and aberration associated with contact lens wear in patients with keratoconus: a pilot study

  • Aug 01, 2014
  • Clinical Optometry
  • Bariah Mohd-Ali +2
  • Research Article
  • Citations18

Comparison of two different orthokeratology lenses and defocus incorporated soft contact (DISC) lens in controlling myopia progression

  • Oct 07, 2023
  • Eye and Vision
  • Na Li +5
  • Research Article

Long-Term Efficacy of CRT, Lucid, Euclid, and IBright Orthokeratology Lenses in Controlling Myopia Progression in Children and Adolescents: A 36-Month Retrospective Cohort Study.

  • Jul 01, 2025
  • Clinical ophthalmology (Auckland, N.Z.)
  • Wulan Xi +4
  • PDF
  • Research Article
  • Citations56

Overnight orthokeratology is comparable with atropine in controlling myopia

  • Mar 31, 2014
  • BMC Ophthalmology
  • Hui-Ju Lin +6
  • Research Article
  • Citations21

Effects of orthokeratology lens on axial length elongation in unilateral myopia and bilateral myopia with anisometropia children

  • Dec 17, 2019
  • Contact Lens and Anterior Eye
  • Ai-Cun Fu +6
  • Research Article
  • Citations6

Rigid gas permeable contact lenses: Out in the cold

  • Jul 10, 2009
  • Contact Lens and Anterior Eye
  • A Jonathan Jackson +1
  • Research Article
  • Citations4

General pain perception sensitivity, lid margin sensitivity and gas permeable contact lens comfort

  • Nov 01, 2020
  • Clinical and Experimental Optometry
  • Daniela S Nosch +3
  • Research Article
  • Citations1

Comparison of the efficacy of orthokeratology and highly aspherical lenslets in slowing myopia progression.

  • Jul 01, 2025
  • Photodiagnosis and photodynamic therapy
  • Chao Li +2
  • Research Article
  • Citations4

Visual performance in the correction of astigmatism with contact lenses: Spherical RGPs versus tonic hydrogels

  • Jul 01, 1994
  • International Contact Lens Clinic
  • Christopher Snyder +2
  • Research Article

Design and 3D Printing of Soft Orthokeratology Lenses.

  • May 15, 2025
  • ACS applied materials & interfaces
  • Baijun Li +5
  • Research Article
  • Citations15

Corneal endothelial morphology results in the Menicon Z 30-day continuous-wear contact lens clinical trial.

  • Jan 01, 2003
  • Eye & Contact Lens: Science & Clinical Practice
  • Joseph T Barr +4
  • PDF
  • Research Article
  • Citations27

Comparison of peripheral refraction and higher-order aberrations between orthokeratology and multifocal soft contact lens designed with highly addition

  • Jan 01, 2022
  • Graefe's Archive for Clinical and Experimental Ophthalmology
  • Yingying Huang +6
  • Research Article
  • Citations36

Near binocular visual function in young adult orthokeratology versus soft contact lens wearers.

  • Feb 16, 2017
  • Contact Lens and Anterior Eye
  • Kate Gifford +3
  • Research Article
  • Citations33

Relative peripheral refraction in myopic children wearing orthokeratology lenses using a novel multispectral refraction topographer

  • Sep 22, 2022
  • Clinical and Experimental Optometry
  • Tao Li +3
  • Research Article
  • Citations2

Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.

  • Apr 18, 2013
  • International journal of ophthalmology
  • Qing Yu +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.