• Home
  • Search
  • 高量子検出効率イメージインテンシファイアの画質評価
  • https://doi.org/10.6009/jjrt.kj00001355564Copy DOI Icon

高量子検出効率イメージインテンシファイアの画質評価

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

A new X-ray image intensifier(Toshiba J-type I.I.)has been developed in response to the digital X-ray image requirements of recent diagnostic systems. In the J-type I.I., the input phosphor screen(450-μm thick, CsI)has been deposited directly on the input window. Since there is no space between the input window and phosphor screen, the scattering of X-rays at the input window is reduced. Consequently, the X-ray detection efficiency over a wide range of X-ray tube operating voltages is also improved. Our studies have shown that the 10-mm contrast ratio is 24(for a 9 inch I.I.). Using International Electrotechnical Commission(IEC)Standard methods, we have concluded that the detective quantum efficiency(DQE)is 70%. We have also compared the characteristics of the J-type I.I.with those of the conventional G-type I.I. using the DFP-2000A DF system(TOSHIBA). The main results are enumerated below. (1)The veiling-glare fraction(VGF)was about 5% less for the J-type I.I. (2)The resolution quality was the same for both types of I.I. (3)Noise was less for the J-type I.I.because of the improvement in DQE. (4)The signal to noise ratio was higher for the J-type I.I.because of the reduction of noise. (5)Receiver operating characteristic(ROS)analysis showed that signal detectability was better for the J-type I.I.

Similar Papers
  • Research Article

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors.

  • Jul 02, 2015
  • Medical physics
  • Amber J Gislason‐Lee +4
  • PDF
  • Research Article
  • Citations56

Cascaded systems analysis of photon counting detectors.

  • Oct 01, 2014
  • Medical physics
  • J Xu +8
  • Research Article
  • Citations2

Design, Characterization, and Modeling for a Modular High-Resolution Solid-State X-Ray Image Intensifier (SSXII)

  • Feb 01, 2013
  • IEEE Transactions on Nuclear Science
  • Ying Huang +7
  • Conference Article
  • Citations6

Volumetric cone-beam CT system based on a 41x41 cm2flat-panel imager

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • David A Jaffray +1
  • Research Article

TH-A-L100F-01: Advanced Techniques for Image Quality Assessment in Digital Radiography

  • Jun 01, 2007
  • Medical Physics
  • Nt Ranger
  • Research Article
  • Citations2

The Detective Quantum Efficiency of Television X-Ray Detectors

  • Aug 01, 1992
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Kenneth Kalata +2
  • Research Article
  • Citations3

Reducing the weight of the EC-L cassette

  • Aug 15, 2002
  • International Journal of Radiation Oncology, Biology, Physics
  • Peter Munro +1
  • Research Article
  • Citations47

A fundamental method to determine the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) for a photon counting pixel detector

  • Sep 22, 2006
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • T Michel +11
  • Research Article
  • Citations39

Segmented phosphors: MEMS-based high quantum efficiency detectors for megavoltage x-ray imaging

  • Feb 03, 2005
  • Medical Physics
  • Amit Sawant +10
  • Conference Article
  • Citations3

A novel x-ray detector design with higher DQE and reduced aliasing: Theoretical analysis of x-ray reabsoprtion in detector converter material

  • Mar 22, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tomi Nano +3
  • Conference Article
  • Citations1

Detective quantum efficiency: a standard test to ensure optimal detector performance and low patient exposures

  • Mar 31, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Terenz R Escartin +2
  • Abstract
  • Citations2

Detective quantum efficiency (DQE) of the Dexela 2923MAM detector according to IEC 62220-1-1:2015

  • Aug 26, 2016
  • Physica Medica
  • V Koukou +10
  • Research Article
  • Citations16

Digital x-ray imaging using amorphous selenium: reduction of aliasing.

  • Oct 28, 1998
  • Medical Physics
  • W G Ji +2
  • Research Article
  • Citations290

Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.

  • Jan 01, 1997
  • Medical Physics
  • J H Siewerdsen +6
  • Research Article

P20 phosphor on polyimide as a large area high-resolution transmission screen for slow scan CCD systems

  • Aug 13, 1995
  • Proceedings, annual meeting, Electron Microscopy Society of America
  • C C Ahn +5
Cactus Communications logo