- Supplementary Content
- 10.1016/j.annder.2009.01.005
Fibrose systémique néphrogénique
- Mar 09, 2009
- Annales de dermatologie et de venereologie
- P Senet
Fibrose systémique néphrogénique
Brain-inspired high-dimensional (HD) computing represents and manipulates data using very long, random vectors with dimensionality in the thousands. This representation provides great robustness for various classification tasks where classifiers operate at low signal-to-noise ratio (SNR) conditions. Similarly, hyperdimensional modulation (HDM) leverages the robustness of complex-valued HD representations to reliably transmit information over a wireless channel, achieving a similar SNR gain compared to state-of-the-art codes. Here, we first propose methods to improve HDM in two ways: (1) reducing the complexity of encoding and decoding operations by generating, manipulating, and transmitting bipolar or integer vectors instead of complex vectors; (2) increasing the SNR gain by 0.2 dB using a new soft-feedback decoder; it can also increase the additive superposition capacity of HD vectors up to 1.7times in noise-free cases. Secondly, we propose to combine encoding/decoding aspects of communication with classification into a single framework by relying on multifaceted HD representations. This leads to a near-channel classification (NCC) approach that avoids transformations between different representations and the overhead of multiple layers of encoding/decoding, hence reducing latency and complexity of a wireless smart distributed system while providing robustness against noise and interference from other nodes. We provide a use-case for wearable hand gesture recognition with 5 classes from 64 EMG sensors, where the encoded vectors are transmitted to a remote node for either performing NCC, or reconstruction of the encoded data. In NCC mode, the original classification accuracy of 94% is maintained, even in the channel at SNR of 0 dB, by transmitting 10,000-bit vectors. We remove the redundancy by reducing the vector dimensionality to 2048-bit that still exhibits a graceful degradation: less than 6% accuracy loss is occurred in the channel at − 5 dB, and with the interference from 6 nodes that simultaneously transmit their encoded vectors. In the reconstruction mode, it improves the mean-squared error by up to 20 dB, compared to standard decoding, when transmitting 2048-dimensional vectors.
Loading PDF
Fibrose systémique néphrogénique
Fibrose systémique néphrogénique
Abdominal Magnetic Resonance Imaging at 3.0 T: What Is the Ultimate Gain in Signal-to-Noise Ratio?
Abdominal Magnetic Resonance Imaging at 3.0 T: What Is the Ultimate Gain in Signal-to-Noise Ratio?
Comparison of SNR gain between quantum illumination radar and classical radar.
It has been proved that quantum illumination (QI) radar has the quantum advantages in error-probability exponent. However, the error-probability exponent is not a recognized figure of merit in the radar literature, nor does it correspond in a straightforward manner to any such figure of merit. Signal to noise ratio (SNR) gain is an important criterion in radar theory. While, the theoretical analysis of quantum enhancement in SNR gain of QI radar has not been reported. In this paper, we compare the physical fundamental of matched filter (MF), which can achieve the optimal SNR gain under white noise in classical radar theory, and phase conjugation (PC) receiver. Furthermore, the quantum enhancement of SNR gain in QI radar is studied. It is shown that QI radar with practical receivers can achieve about 3dB quantum advantage in SNR gain. In addition, in the case of extremely weak signal, it can potentially achieve tens of dB enhancement in SNR gain compared with the MF based classical radar.
Read moreUtility of respiratory‐navigator‐rejected k‐space lines for improved signal‐to‐noise ratio in three‐dimensional cardiac MR
To develop and evaluate a technique that uses the k-space lines rejected by prospective respiratory navigator (NAV) to improve the signal-to-noise ratio (SNR) without increasing the scan time. In conventional image reconstruction, the motion-corrupted k-space lines rejected by the NAV are not used. In this study, a set of translational motion parameters for the NAV-rejected lines and a phase-corrected average for the k-space line are estimated jointly using a maximum-likelihood approach and the information from the corresponding accepted k-space lines. Left coronary artery images were acquired in 10 healthy adult subjects, and the proposed approach incorporating the NAV-rejected lines was compared with the conventional dataset with NAV-accepted lines only, as well as a simple average of all k-space lines, in terms of SNR, normalized vessel sharpness and qualitative image scores on a four-point scale (1 = poor, 4 = excellent). Late gadolinium enhancement images of the left atrium were also acquired in 21 patients with atrial fibrillation pre- or post-pulmonary vein isolation. Images reconstructed with the proposed, conventional, and simple averaging methods were compared in terms of SNR, and subjective image quality on a four-point scale. For coronary MRI, there was a significant improvement in SNR with the proposed technique, but no significant difference in normalized vessel sharpness or qualitative image scores were observed with respect to the conventional method. Simple averaging resulted in an SNR gain, but significant loss in vessel sharpness and image quality. For late gadolinium enhancement, there was a significant increase in SNR, but no significant differences were observed in subjective image quality scores between the proposed and conventional methods. There was an SNR gain, but image quality loss for simple averaging, when compared with the conventional technique. In both coronary MRI and late gadolinium enhancement, the SNR gain of the proposed method was not significantly different than the maximum theoretical SNR gain. The proposed technique improves SNR using the additional information from NAV-rejected k-space lines, while providing similar image quality to standard reconstruction using motion-free k-space data only, with no increase in scan time.
Read moreComparison of image Signal-to-Noise Ratio and Noise Equivalent Counts in Time-of-Flight PET
In PET imaging, Noise Equivalent Counts (NEC) represents an estimate of the number of true coincidences necessary in an ideal system to reach the Signal-to-Noise Ratio (SNR) obtained in a real system in the presence of scatter and random coincidences. NEC has been shown to be proportional to the square of image SNR and it is used as an index of the general system performance for conventional PET images. As clinical Time-of-Flight (TOF) PET scanners are now available from all major camera manufacturers, the original NEC formula does not directly account for the contribution of TOF timing resolution to the image SNR. This study measures SNR in images of a uniform phantom for TOF and Non-TOF PET at different NEC levels to study the relationship between SNR and NEC. A cylindrical uniform phantom, 20 cm in diameter was scanned covering a range of activity levels on a Philips Gemini TF scanner. From the original scans, at each activity level, a set of data realizations were obtained through bootstrapping. NEC is calculated from the original datasets using both the original NEMA formula and alternative formulas that include the TOF gain. SNR is calculated from the bootstrapped images, reconstructed with both TOF and Non-TOF algorithms and the relationship between SNR and NEC is investigated. The results show an appreciable gain in SNR obtained by using TOF information, and a correspondence between the region where NEC and SNR peaks occur. The relationship between the two quantities, however, is not clearly established and future studies including finer sampling on the acquisition of larger phantoms and simulations are needed.
Read moreMRI of the carotid artery at 7 Tesla: Quantitative comparison with 3 Tesla
To evaluate the 7 Tesla (T) MRI of the carotid arteries, as quantitatively compared with 3T. The 7T MRI of the carotid arteries was performed in six healthy subjects and in two patients with carotid stenosis. The healthy group was scanned at 3T and at 7T, using current coil setups at both field strengths. T1 and T2 values of the normal carotid vessel wall were assessed at both field strengths. B1 (+) maps and signal to noise ratio (SNR) maps were obtained, as well as T1 weighted images with a resolution as high as 0.4 × 0.4 × 1.5 mm(3) . The T1 of the normal carotid vessel wall was found to be 1227 ± 47 ms at 3T and 1628 ± 130 ms at 7T, while a T2 of 55 ± 11 ms at 3T and 46 ± 4 ms at 7T was found. A twofold average gain in SNR at the carotid arteries was found with 7T. T1 weighted images showed an increased SNR at 7T for all subjects. Evaluation between 3T and 7T carotid MRI with optimized setups at both field strengths showed improved SNR at 7T, an increase in vessel wall T1 and a decrease in vessel wall T2.
Read moreThe Effect of Otoacoustic Emission Stimulus Level on the Strength and Detectability of the Medial Olivocochlear Reflex.
Previous work demonstrates the importance of a high signal to noise ratio (SNR) when using transient evoked otoacoustic emissions (TEOAEs) to assay the medial olivocochlear reflex (MOCR). Increasing stimulus level provides one means to increase TEOAE SNR. However, this may come at the expense of a smaller MOCR effect. It is not clear whether the gain in SNR associated with the use of higher stimulus levels outweighs the disadvantage of a potentially smaller MOCR effect. The present study investigated the strength and detectability of the MOCR when assayed using TEOAEs at different stimulus levels. The hypothesis was that although the strength of the MOCR decreases with increasing stimulus level, the occurrence of statistically significant MOCR effects increases due to an increase in TEOAE SNR. Twenty-five young adult females with normal hearing participated in the study. TEOAEs were measured in the right ear with and without broadband noise presented in the left ear. The strength of the MOCR was quantified as the percent difference in the TEOAE between the contralateral noise and quiet conditions. Statistical bootstrapping was used to detect significant MOCR effects in individual subjects across different frequency bands and stimulus levels. The relationship between a detectable MOCR (response variable) and frequency, stimulus level, TEOAE SNR, MOCR strength, and subject (predictor variables) was evaluated using generalized linear mixed-effect models. The number of statistically significant MOCR effects increased with stimulus level at all frequencies. Occurrence was highest for the 2-kHz TEOAE frequency band and lowest for the 4-kHz frequency band. The strength of the MOCR decreased with increasing click level. TEOAE SNR, MOCR strength, and stimulus level were significant predictors of a detectable MOCR: The likelihood of a detectable MOCR increased with TEOAE SNR, MOCR strength, and stimulus level. Despite a reduction in the strength of the MOCR with increasing stimulus level, the detectability of the MOCR increased. This is due, in part, to an increase in TEOAE SNR with stimulus level. For clinical implementation of TEOAE-based MOCR assays, achieving a high SNR is necessary to permit the detection of the MOCR in individual patients.
Read moreBit error rate analysis of the scheduled TAS with MRC for CR-MIMO systems
Bit error rate analysis of the scheduled TAS with MRC for CR-MIMO systems
Outage Probability of Zero Forcing Precoded Scheduling System for Multiple Input Multiple Output Broadcast Transmission
In this paper, we investigate an error performance issue of a multiple-input multiple-output (MIMO) broadcast system with zero-forcing (ZF) precoder. We propose a ZF-precoded scheduling system for MIMO broadcast transmission which selects a user set with the maximum effective signal to noise ratio (SNR) through feedback information. The tight closed-form expression of the proposed scheduling system for outage probability is derived. We also present asymptotic analysis to quantify diversity order and SNR gain. This analysis results show that the proposed scheduling system provides error performance improvement by diversity order gain, which comes from multi-user diversity (MUD) over the conventional ZF-precoding system.
Read moreFourier decomposition pulmonary MRI using a variable flip angle balanced steady-state free precession technique.
Fourier decomposition (FD) is a noninvasive method for assessing ventilation and perfusion-related information in the lungs. However, the technique has a low signal-to-noise ratio (SNR) in the lung parenchyma. We present an approach to increase the SNR in both morphological and functional images. The data used to create functional FD images are usually acquired using a standard balanced steady-state free precession (bSSFP) sequence. In the standard sequence, the possible range of the flip angle is restricted due to specific absorption rate (SAR) limitations. Thus, using a variable flip angle approach as an optimization is possible. This was validated using measurements from a phantom and six healthy volunteers. The SNR in both the morphological and functional FD images was increased by 32%, while the SAR restrictions were kept unchanged. Furthermore, due to the higher SNR, the effective resolution of the functional images was increased visibly. The variable flip angle approach did not introduce any new transient artifacts, and blurring artifacts were minimized. Both a gain in SNR and an effective resolution gain in functional lung images can be obtained using the FD method in conjunction with a variable flip angle optimized bSSFP sequence.
Read moreFeasibility and Robustness of 3T Magnetic Resonance Angiography Using Modified Dixon Fat Suppression in Patients With Known or Suspected Peripheral Artery Disease.
Objective: Contrast-enhanced magnetic resonance angiography (CE-MRA) is a well-established non-invasive imaging technique for the assessment of peripheral artery disease (PAD). A subtractionless method using modified Dixon (mDixon) fat suppression showed superior image quality at 1.5T over the common subtraction method, using a three-positions stepping table approach with a single dose of contrast agent. The aim of this study was to investigate the feasibility of subtractionless first-pass peripheral MRA at 3T in patients with known or suspected PAD and to compare the performance in terms of vessel-to-background contrast (VBC), signal-to-noise ratio (SNR), and subjective image quality to conventional subtraction MRA.Methods: Ten patients [mean age 69 years ± 12 standard deviation (SD)] with known or suspected PAD were examined on a clinical 3T scanner (Ingenia, Philips Healthcare, Best, Netherlands) at three table positions using subtractionless and subtraction first-pass peripheral MRA. Two readers rated image quality on a four- point scale. Interobserver agreement was expressed in quadratic weighted κ values. VBC was assessed with a semi-automated process and SNR was compared in a healthy volunteer.Results: Subjective image quality was significantly better with the subtractionless method overall (mean image quality for mDixon imaging: 2.88 ± 0.32 SD vs. for subtraction imaging: 2.57 ± 0.48 SD; P < 0.001) and per table position (abdominal position: 2.88 ± 0.32 vs. 2.57 ± 0.48 SD; P < 0.001); upper leg position: (2.97 ± 0.15 SD vs. 2.68 ± 0.37 SD; P < 0.001; lower leg position: 2.60 ± 0.50 SD vs. 2.13 ± 0.60 SD; P < 0.001). Vessel-to-background contrast increased by 22% with the subtractionless method overall (mean VBC for mDixon imaging: 23.16 ± 8.4 SD vs. for subtraction imaging: 19.00 ± 8.1 SD; factor 1.22, P < 0.001). SNR was 82% higher with the subtractionless method (overall SNR gain 1.82; P < 0.001).Conclusion: This study demonstrated the feasibility and robustness of subtractionless first-pass peripheral MRA at 3T in patients with known or suspected PAD using a three- positions stepping table approach with a single dose of contrast agent. It showed increased image quality compared to the conventional subtraction method and superior performance in terms of SNR and vessel-to-background contrast.
Read moreA Near‐Field Coupling Array Enables Parallel Imaging and SNR Gain in MRI
Wireless radiofrequency (RF) coils based on metasurfaces hold great promise for improving clinical magnetic resonance imaging (MRI) workflows by eliminating the need for cable connections to the patient bed and simplifying coil structures. A fundamental requirement for their clinical adoption is the ability to support parallel imaging, which reduces examination time and improves efficiency. Moreover, the implementation of parallel imaging often comes at the expense of image signal‐to‐noise ratio (SNR). Although several wireless RF coils incorporating metamaterials are reported, most do not support parallel imaging and many deliver suboptimal SNR performance. In this work, a novel wireless RF coil architecture is proposed, termed the near‐field coupling array (NFCA), which demonstrates both excellent SNR performance and robust parallel imaging capabilities. A general theoretical framework is presented that establishes a foundation for applying metasurface arrays in magnetic resonance RF coil design. The SNR expression for this architecture is derived from two perspectives, and its fundamental principles are validated through case studies. Experimental results show that the NFCA achieves a 66% SNR improvement over a conventional commercial RF coil architecture (i.e., a wired coil) while its average acceleration factor exceeds 94% of that of the commercial coil.
Read morePerturbative corrections to stochastic resonant quantizers
Perturbative corrections to stochastic resonant quantizers
A compact Fourier transform spectrometer with no moving parts for laser induced breakdown spectroscopy
We report the development of a portable single-shot Fourier transform spectrometer for application in laser induced breakdown spectroscopy (LIBS) with a particular emphasis on remote or standoff LIBS. The device, based on a design by Harvey and Padgett[1], has a number of inherent features that give it performance advantages over a portable grating spectrometer, in particular a gain in signal to noise ratio (SNR). Tests with low-pressure discharge lamps show a gain in SNR of at least five times that of a traditional portable grating spectrometer in stand-off mode. In addition, the instrument has also demonstrated the ability to measure the spectrum from a short or ultrashort pulsed source in a single shot, e.g. a laser produced plasma.
Read moreSignal-to-Noise Ratio Improvement of MAMR on CoX/Pt Media
The signal-to-noise ratio (SNR) gain of microwave-assisted magnetic recording (MAMR) with a spin-transfer oscillator is analyzed by a micromagnetic model simulating the write process on a CoX/Pt media, by including the Voronoi polycrystalline microstructure built upon a regular mesh of micromagnetic cells. With a fixed head of 40 nm-width main pole and a 10.5 kOe maximum perpendicular field, a 2 dB SNR gain is found for low-coercivity media (0 K $H_{c} kOe) and a 4 dB gain is obtained for high-coercivity media (0 K $H_{c}>14$ kOe). Besides, the MAMR performance considering the finite rise time of single-pole-type head field in a bit is also calculated. It is found that the MAMR SNR gain is obtained in the media with lower anisotropy because of the weak writing capacity during the rise time.
Read more