- Research Article
2304
- 10.1016/j.mseb.2017.12.036
Semiconductor metal oxide gas sensors: A review
- Jan 05, 2018
- Materials Science and Engineering: B
- Ananya Dey
Semiconductor metal oxide gas sensors: A review
Electronic noses or array sensors are very popular in the last decades because of their ability to avoid the cross-sensitivity issue in semiconductor metal oxide (SMO) gas sensors. The identification and discrimination of toxic gases have a significant role in industrial applications. This work encompasses the classification of carbon monoxide (CO) and methane (CH4) toxic gases using a gas sensor array. Classification algorithm based on artificial neural network (ANN) with one hidden layer is used for identifying the gas type from the gas mixture. This metal oxide gas sensor array is built with six SMO gas sensors, which are sensitive to several types of gases. The ANN model ensures a training accuracy of 94.57% and a validation accuracy of 93.33%. For practical applications, the gas concentration is randomly assigned in the training stage. Neural network-based classification algorithm provides better performance in identifying the type of gas.
Semiconductor metal oxide gas sensors: A review
Semiconductor metal oxide gas sensors: A review
Application of Deep Learning Network for Humidity Compensation of Semiconductor Metal Oxide Gas Sensors
In this research, we propose a humidity compensation method using a deep learning network for minimizing the effect of humidity on the semiconductor metal oxide (SMO) gas sensors. The SMO gas sensors were fabricated by depositing In<inf>2</inf>O<inf>3</inf> on a suspended microheater platform, and the gas tests were conducted under various humidity conditions using NO<inf>2</inf> gas. The gas sensing data and humidity data were simultaneously used as input data of the deep learning network for real-time humidity compensation. Through the proposed method, we successfully improved the accuracy of predicting the concentration of NO<inf>2</inf> gas in different humidity conditions.
Read moreMachine Learning-Assisted Gas-Specific Fingerprint Detection/Classification Strategy Based on Mutually Interactive Features of Semiconductor Gas Sensor Arrays
A high-performance machine learning-assisted gas sensor strategy based on the integration of supervised and unsupervised learning with a gas-sensitive semiconductor metal oxide (SMO) gas sensor array is introduced. A 4-SMO sensor array was chosen as a test sensor system for detecting carbon monoxide (CO) and ethyl alcohol (C2H5OH) mixtures using 15 different combinations. Gas sensing detection/classification was performed with different numbers of gas sensor and machine learning algorithms. K-Means clustering was successfully employed to rationally identify the similarity features of targeted gases among 4 different groups, i.e., matrix gas, two single-component gases, and one two-gas mixture, based on only unlabeled voltage-based gas sensing information. Detailed classification was performed through a multitude of supervised algorithms, i.e., 2-layer artificial neural networks (ANNs), 4-layer deep neural networks (DNNs), 1-dimensional convolutional neural networks (1D CNNs), and 2-dimensional CNNs (2D CNNs). The numerical-based DNNs and image-based CNNs are shown to be excellent approaches for gas detection and classification, as indicated by the highest accuracy and lowest loss indicators. Through the analysis of the influence of the number of sensors on the arrayed gas sensor system, the application of machine learning methodology to an arrayed gas sensor system demonstrates four unique features, i.e., a data augmentation methodology, machine learning approach of combining K-means clustering and neural networks, and a systematic approach to optimized sensor combinations, potentially leading to the practical sensor networks based on chemical sensors. Even two SMO sensor combinations are shown to be highly effective in gas discrimination against diverse gas environments assisted through numeric-based DNNs and image-based 1D CNNs, overcoming the simple clustering proposed through the unsupervised K-means clustering.
Read moreRecent Progress in Low-Power-Consumption Metal Oxide Semiconductor Gas Sensors
Metal oxide semiconductor (MOS) gas sensors offer several advantages, including low cost, high accuracy, and ease of miniaturization. Thus, they are excellent candidates for environmental monitoring and food spoilage detection applications, particularly in the safe Internet of Things field or for portable instruments. Typically, there are two general routes for realizing low-power-consumption MOS gas sensors: room-temperature MOS gas sensors or MEMS MOS gas sensors. The review focuses on the detection of four typical gases, namely methane, hydrogen, carbon monoxide, and nitrogen dioxide, systematically summarizing and analyzing the most recent results of low-power-consumption MOS gas sensors. The 2D materials, MOS composites, and 3D structured composites exhibit excellent room-temperature gas detection capabilities. The mechanism of the room-temperature gas sensors is also discussed in detail. Another route is MEMS MOS gas sensors. First, the progress of the micro-hotplate research is introduced. Then, several of the latest reported MEMS MOS gas sensors are shown and compared. The gas sensing mechanism of these MEMS MOS gas sensors is also given. The paper will provide a valuable guide for researchers in the MOS gas sensor field, particularly for those working towards low-power-consumption MOS gas sensors.
Read moreSelective Detection of Acetone and Hydrogen Sulfide for the Diagnosis of Diabetes and Halitosis Using SnO2 Nanofibers Functionalized with Reduced Graphene Oxide Nanosheets
Sensitive detection of acetone and hydrogen sulfide levels in exhaled human breath, serving as breath markers for some diseases such as diabetes and halitosis, may offer useful information for early diagnosis of these diseases. Exhaled breath analyzers using semiconductor metal oxide (SMO) gas sensors have attracted much attention because they offer low cost fabrication, miniaturization, and integration into portable devices for noninvasive medical diagnosis. However, SMO gas sensors often display cross sensitivity to interfering species. Therefore, selective real-time detection of specific disease markers is a major challenge that must be overcome to ensure reliable breath analysis. In this work, we report on highly sensitive and selective acetone and hydrogen sulfide detection achieved by sensitizing electrospun SnO2 nanofibers with reduced graphene oxide (RGO) nanosheets. SnO2 nanofibers mixed with a small amount (0.01 wt %) of RGO nanosheets exhibited sensitive response to hydrogen sulfide (Rair/Rgas = 34 at 5 ppm) at 200 °C, whereas sensitive acetone detection (Rair/Rgas = 10 at 5 ppm) was achieved by increasing the RGO loading to 5 wt % and raising the operation temperature to 350 °C. The detection limit of these sensors is predicted to be as low as 1 ppm for hydrogen sulfide and 100 ppb for acetone, respectively. These concentrations are much lower than in the exhaled breath of healthy people. This demonstrates that optimization of the RGO loading and the operation temperature of RGO-SnO2 nanocomposite gas sensors enables highly sensitive and selective detection of breath markers for the diagnosis of diabetes and halitosis.
Read moreHigh Accuracy Real-Time Multi-Gas Identification by a Batch-Uniform Gas Sensor Array and Deep Learning Algorithm.
Semiconductor metal oxide (SMO) gas sensors are attracting great attention as next-generation environmental monitoring sensors. However, there are limitations to the actual application of SMO gas sensors due to their low selectivity. Although the electronic nose (E-nose) systems based on a sensor array are regarded as a solution for the selectivity issue, poor accuracy caused by the nonuniformity of the fabricated gas sensors and difficulty of real-time gas detection have yet to be resolved. In this study, these problems have been solved by fabricating uniform gas sensor arrays and applying the deep learning algorithm to the data from the sensor arrays. Nanocolumnar films of metal oxides (SnO2, In2O3, WO3, and CuO) with a high batch uniformity deposited through glancing angle deposition were used as the sensing materials. The convolutional neural network (CNN) using the input data as a matrix form was adopted as a learning algorithm, which could conduct pattern recognition of the sensor responses. Finally, real-time selective gas detection for CO, NH3, NO2, CH4, and acetone (C3H6O) gas was achieved (minimum response time of 1, 8, 5, 19, and 2 s, respectively) with an accuracy of 98% by applying preprocessed response data to the CNN.
Read moreImproved Sensing Capability of Integrated Semiconducting Metal Oxide Gas Sensor Devices †
Semiconducting metal oxide (SMO) gas sensors were designed, fabricated, and characterized in terms of their sensing capability and the thermo-mechanical behavior of the micro-hotplate. The sensors demonstrate high sensitivity at low concentrations of volatile organic compounds (VOCs) at a low power consumption of 10.5 mW. In addition, the sensors realize fast response and recovery times of 20 s and 2.3 min, respectively. To further improve the baseline stability and sensing response characteristics at low power consumption, a novel sensor is conceived of and proposed. Tantalum aluminum (TaAl) is used as a microheater, whereas Pt-doped SnO2 is used as a thin film sensing layer. Both layers were deposited on top of a porous silicon nitride membrane. In this paper, two designs are characterized by simulations and experimental measurements, and the results are comparatively reported. Simultaneously, the impact of a heat pulsing mode and rubber smartphone cases on the sensing performance of the gas sensor are highlighted.
Read moreSensing Selectivity Enhancement of Palladium Oxide Toward VOCs Using Characteristic Response Features below 250oc
Breath analysis has received much attention for its non-invasive monitoring of human pathological conditions. The exhaled volatile organic compounds (VOCs) from patients can be utilized as potential biomarkers of specific diseases and disorders. For instance, acetone can be the indicator of diabetes and ethanol is an important interfering gas during the breath analysis. This work focuses on the improvement of the gas sensing selectivity for ethanol and acetone, by taking advantage of the intriguing redox behavior of palladium oxide (PdO) in the temperature range between 100 and 250oC. Metal oxide semiconductor (MOS) gas sensors have been extensively studied because of their rapid response and high sensitivity. Furthermore, fabrication of MOS gas sensors is simple and compatible to existing semiconductor fabrication processes. In this study, sputter-deposited PdO nanoflake thin films were used as the sensing material. PdO is a p-type semiconductor with a band gap of 2.2eV and thermally stable up to 800oC in atmosphere. In addition, PdO has a high catalytic reactivity toward reducing gases, such as CO and CH4. For the application of gas sensing, PdO is a good sensitizer in gas sensors for sensitivity and selectivity improvement. According to our previous works, PdO demonstrates characteristic sensing responses toward reducing gases due to its distinctive reduction and reoxidation behaviors. The characteristic sensing response may be ascribed to the reduction of PdO and subsequent reoxidation. In general, the gas sensing principle based on MOS gas sensors is described by two sensing mechanism models: ionosorption and oxygen vacancy models. The characteristic redox property of PdO can modify the gas sensing behavior predicted by the two models. Moreover, adsorption of intermediate adspecies on the PdO sensor in operation also affects the sensing response. Conventional MOS sensors use the sensor signal, which is typically determined under a steady sensing condition, as the input variable for the data processing of gas classification. In this case, simple mathematical models, such as principle component analysis (PCA) and linear discriminant analysis (LDA), can be used to classify the input signals. However, these simple models have poor performance in selectivity improvement and thus have limited applications for MOS gas sensors. Since the PdO gas sensor demonstrates dynamic characteristic responses toward VOC gases, we extracted characteristic response features as the input variables for the artificial neural network (ANN) method to improve the selectivity of VOC gas sensing. Figure (a) shows the electrical sensing response of PdO exposed to a dry air gas mixture of VOCs at 250oC. Ammonia is also included in the study because it is a strong reducing agent and an important indicator of renal diseases and asthma. At the early stage of sensing, the sensing current promptly drops upon the exposure to the gases. The sensing current then gradually rises and reaches the equilibrium. The first prompt current drop can be ascribed to reduction of preadsorbed oxygen anions and PdO by VOCs on the basis of ionosorption and oxygen vacancy models. Reducing gases can react with oxygen anions and lattice oxygen atoms, releasing negative charges to the PdO sensor and thus decreasing its conductance. The latter current rise is a result of the formation of metal Pd nano-domain, which is a surface product of the PdO reduction. Chemical characterizations indicate that ethanol, acetone and ammonia undergo dehydrogenation on the PdO surface. These reducing gases can provide a plentiful amount of hydrogen to reduce the PdO substrate, depending on their bond strength and adsorption structure on the sensor. The reduction rate of the PdO substrate greatly depends on the surface coverage of hydrogen adatoms and the sensing temperature. As a result, the PdO sensor yields distinct response profiles when it is exposed to the studied gases at different temperatures. Two characteristic features extracted from the response profiles for the ANN method are depicted in figure (b). The two features are the slope of the conductance rise trace and the ratio of conductance change at two time points. The classification result is listed in table 1, demonstrating a high classification rate. In summary, the gas sensing behavior of PdO toward VOCs was studied. Characteristic features from the electrical response profiles were used as variables for the ANN pattern recognition algorithm to enhance the sensing selectivity of PdO toward VOCs. Figure 1
Read moreA Compact, Reliable and Efficient 16 Channel Power Supply for the Automated Screening of Semiconducting Metal Oxide Gas Sensors
The choice of suitable semiconducting metal oxide (MOX) gas sensors for the detection of a specific gas or gas mixture is time-consuming since the sensor’s sensitivity needs to be characterized at multiple temperatures to find its optimal operating conditions. To obtain reliable measurement results, it is very important that the power for the sensor’s integrated heater is stable, regulated and error-free (or error-tolerant). Especially the error-free requirement can be only be achieved if the power supply implements failure-avoiding and failure-detection methods. The biggest challenge is deriving multiple different voltages from a common supply in an efficient way while keeping the system as small and lightweight as possible. This work presents a reliable, compact, embedded system that addresses the power supply requirements for fully automated simultaneous sensor characterization for up to 16 sensors at multiple temperatures. The system implements efficient (avg. 83.3% efficiency) voltage conversion with low ripple output (<32 mV) and supports static or temperature-cycled heating modes. Voltage and current of each channel are constantly monitored and regulated to guarantee reliable operation. To evaluate the proposed design, 16 sensors were screened. The results are shown in the experimental part of this work.
Read moreA Compact 16 Channel Embedded System with High Dynamic Range Readout and Heater Management for Semiconducting Metal Oxide Gas Sensors
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100 Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
Read moreChemiresistive gas sensors based on electrospun semiconductor metal oxides: A review
Chemiresistive gas sensors based on electrospun semiconductor metal oxides: A review
Selectivity Enhancement of ZnO Toward Reducing Gases Using Characteristic Response Features Based on Surface Kinetics below 250°C
Biomarkers in human breath are proven to be associated with the metabolic and pathological conditions of personal health. For instance, acetone can be an indicator of diabetes and carbon monoxide is a biomarker of asthma. Therefore, monitoring these biomarkers in human breath can be used for disease diagnosis. Moreover, due to its non-invasive and convenient diagnosis attribute, breath analysis is gaining its popularity. Metal oxide semiconductor (MOS) gas sensors are extensively studied because of their rapid response and high sensitivity. In addition, MOS gas sensors may become a reliable and inexpensive tool for breath analysis because fabrication of MOS gas sensors is simple and fully compatible with existing IC fabrication processes. However, although MOS gas sensors exhibit a sensitive response toward various gases, conventional MOS gas sensors usually show poor selectivity toward target gases. To enhance the selectivity of MOS gas sensors toward target gases, sensor arrays are generally used to monitor input gases under a steady sensing condition and the electrical response of the sensor signals is used as the input variable for gas classification algorithms, such as linear discriminant analysis (LDA) and principle component analysis (PCA). In this work, we studied the sensing response property of ZnO toward various reducing gases, and characteristic response features were examined for selectivity improvement. The ZnO sensor was prepared by sputter-depositing a 20 nm-thick ZnO thin film on the Al electrodes, which were thermal evaporated on a thermal oxide substrate and patterned by a stainless steel (SS) hard mask. During the gas sensing test, the ZnO sensor was exposed to a dry air gas mixture of acetone, ethanol, carbon monoxide, ammonia and hydrogen of various concentrations at 250 oC. The ZnO gas sensor demonstrates a characteristic electrical response toward reducing gases. The sensor shows a prompt electrical conductance rise upon the target gases exposure followed by a gradual drop; the conductance will then slowly level off. The dynamic characteristic sensing response is ascribed to be associated with various surface processes taking place on the sensor during gas sensing. According to our previous works, PdO demonstrates a similar sensing response characteristic but in an opposite manner because it is a p-type semiconductor while ZnO is an n-type one. The PdO sensor exposed to a dry air gas mixture of VOCs at 250oC shows a valley shaped response feature. Upon the gas exposure, the PdO sensor shows promptly drop in conductance, followed by a gradual rise and then by a conductance saturation. The first prompt conductance drop can be ascribed to adsorbed and lattice oxygen removal, releasing negative charge to PdO. The latter conductance rises is due to negative charge transfer to adspecies from Pd nanoclusters formed as a result of PdO reduction. The nanoclusters can be finally reoxidized leading to the conductance saturation. We proposed herein similar surface processes on the ZnO sensor for the characteristic response features observed in this work. The characteristic gas sensing features can be utilized as chemical fingerprints for gas classification. By using the slope of the conductance rise, which suggests the effect of oxygen removal and the slope of the conductance drop, which suggests the effect of the Zn nanocluster formation and charge donation to adspecies from Zn nanocluster as variables for principal component analysis, different gases can be satisfactorily classified into separated clusters. In summary, characteristic electrical response features are observed for the ZnO sensor depending on target gases. The response features are a result of surface processes simultaneously occurring on the ZnO sensor as a result of the exposure to reducing gases. The distinct response feature can be utilized for characteristic feature extraction in pattern recognition algorithms to improve the selectivity of the sensor.
Read moreUSmell: exploring the potential for gas sensors to classify odors in ubicomp applications relative to airflow and distance
Previous research has shown that gas sensors can be used to classify odors when used in highly controlled experimental testing chambers. However, potential ubicomp applications require these sensors to perform an analysis in less controlled environments, particularly at a distance. In this paper, we discuss our design of uSmell--a gas sensor system for sensing smell in ubicomp environments--and an evaluation of its basic efficacy, effects of airflow and distance on classification accuracy, and in an example application. Our system samples an odor fingerprint from eight metal oxide semiconductor (MOS) gas sensors every second. It then processes the time series data to extract three features that highlight how time and distance affect the eight MOS gas sensors' ability to react to the gas molecules released by an odor every 5 s; this generates 24 features in total that are then used to train a decision tree classifier. Using this approach, our system can classify a set of odors with 88 % accuracy when placed both in a small container with the samples and in open air 0.5---2 m from the odor samples. We also demonstrate its ability to classify odors in less controlled environments that might be targets for ubicomp applications by deploying it in a bathroom for a week. These results show the potential for applying this sensing toward the development of context-aware systems, such as lifelogging applications or those geared toward enhancing the sustainability of natural resources (e.g., an automatic dual-flush toilet that always uses an appropriate amount of water based on the user's toileting activities).
Read moreApplication of Unsupervised/Supervised Machine Learning to Harmful Gas Detection/Classification Based on Mutually-Interacting Semiconductor Metal Oxide Gas Sensors
Chemical and/or physical sensors are employed at domestic and industrial sites with the aim to perform a variety of functions, such as prediction, forecasting, prognostics, remaining useful life estimation, anomaly detection, and trend analysis. The sensing information contain the analog signals originating from gas-generated signals, pressure, shear, strain, torsion, temperature, humidity, illumination, electromagnetic radiation, sound, and vibration. Chemical gas sensors can be categorized mainly as semiconductor metal oxide (SMO), electrochemical, or photo-ionization detection (PID) sensors. SMO gas sensors are based on adsorption and desorption of gas molecules onto/from semiconductor metal oxides and however, suffer from the low selectivity to diverse gas species, i.e., the mutually interacting features.Here, we report a high-performance machine learning strategy for gas detection/discrimination against harmful gas combination and adopt the synergistic integration of supervised and unsupervised learning by exploiting a SMO gas sensor array. A 4 SMO sensor array was constructed for detecting carbon monoxide and ethyl alcohol (C2H5OH) mixtures using 15 different gas combinations. Gas detection/discrimination performance was probed in terms of different numbers of gas sensor integrated as an array and machine learning algorithms. Unsupervised K-Means clustering was successfully applied to the rational identification of the similarity features of targeted gases among 4 different groups, which are listed as matrix gas, two single-component gases, and one two-gas by employing only unlabeled voltage-based gas sensing information. Detailed classification was performed through a multitude of supervised algorithms, i.e., 2-layer artificial neural networks (ANNs), 4-layer deep neural networks (DNNs), 1-dimensional convolutional neural networks (1D CNNs), and 2-dimensional convolutional neural networks (2D CNNs). The numerical-based DNNs and image-based CNNs are evaluated to be excellent approaches for gas detection/classification, as corroborated by the highest accuracy and lowest loss parameters.Through the systematic investigation on the influence of the number of sensors on the arrayed gas sensor system, the applicability of machine learning methodology to an arrayed SMO gas sensor system is justified by the four unique features, i.e., i) a data augmentation methodology, ii) machine learning approach of combining K-means clustering and neural networks, and iii) a systematic approach to optimized sensor combinations, potentially recommending the minimized sensor systems based on chemical gas sensors against harmful gas species. Even two SMO sensor combinations are shown to be highly effective in performing gas discrimination against harmful gas species assisted through either numeric-based DNNs or image-based 1D CNNs, overcoming the simple clustering proposed through the unsupervised K-means clustering.
Read moreUnderstanding Semiconducting Metal Oxide Gas Sensors
Research activities regarding semiconductor metal oxide gas sensors are booming all over the world. The importance of semiconductor metal oxide gas sensors has been generally recognized in different research communities, which have been actively promoting fundamental research and practical application of gas sensors. It is well known that semiconductor metal oxide gas sensors have been widely used in various fields, and they are becoming a key demand in modern high-tech society. Therefore, basic research and application technology of semiconductor metal oxide gas sensors have attracted wide attention. This chapter briefly introduces the development history and research progress of semiconductor gas sensors, and particular emphasis is put on introducing recent innovative research and edge-cutting techniques on semiconductor gas sensors.
Read more