• Home
  • Search
  • Operation and performance of the CMS Level-1 Calorimeter Trigger upgrade
  • Open Access IconOpen Access
  • Cite Icon1
  • https://doi.org/10.1109/nssmic.2015.7581866Copy DOI Icon

Operation and performance of the CMS Level-1 Calorimeter Trigger upgrade

  • Oct 1, 2015
  • P Klabbers
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The Large Hadron Collider (LHC) at CERN has begun the physics program for Run 2. The center-of-mass energy has risen from 8 to 13 TeV and the instantaneous luminosity will increase for both proton and heavy-ion running. This will make it more challenging to trigger on interesting events since the number of interactions per crossing (pile-up) and the overall trigger rate will be significantly larger than LHC Run 1. The Compact Muon Solenoid (CMS) experiment has installed a two-stage upgrade to their Calorimeter Trigger to ensure that the trigger rates can be controlled and the thresholds can stay low, so that physics data collection will not be compromised. The first-stage upgrade is installed and includes new electronics and duplicated optical links so that the LHC Run 1 CMS calorimeter trigger is still functional and algorithms can be developed while data taking continues. The second-stage will fully replace the calorimeter trigger at CMS with AMC form-factor boards and an optical link system, and require that the updates to the calorimeter back-ends, the source of the trigger primitives, are also installed and operational. The stage-2 system's boards will utilize Xilinx Virtex 7 FPGAs and have hundreds of high-speed links operating at up to 10 Gbps to maximize data throughput. The integration, commissioning, operation, and performance of stage-1 for 2015 data taking and stage-2 for triggering in 2016 will be described.

Similar Papers
  • PDF
  • Conference Article

Operation and performance of a new microTCA-based CMS calorimeter trigger in LHC run 2

  • Oct 01, 2016
  • P Klabbers
  • Conference Article

Improved thermal monitoring in particle accelerators using FBGs: first insights from the iPipe Project in LHC Run 3

  • Jan 01, 2023
  • Francesco Fienga +9
  • PDF
  • Research Article

Trigger Rate Monitoring Tools at CMS

  • Jan 01, 2019
  • EPJ Web of Conferences
  • Andrew Wightman +3
  • Research Article
  • Citations6

Gas mixture quality studies for the CMS RPC detectors during LHC Run 2

  • Apr 01, 2021
  • Journal of Instrumentation
  • A Gelmi +2
  • Research Article
  • Citations3

Flexible trigger menu implementation on the Global Trigger for the CMS Level-1 trigger upgrade

  • Oct 01, 2017
  • Journal of Physics: Conference Series
  • Takashi Matsushita
  • Research Article
  • Citations7

Radiation testing of electronics for the CMS endcap muon system

  • Sep 17, 2012
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • B Bylsma +16
  • Research Article
  • Citations4

A brief review of measurements of electroweak bosons at the LHCb experiment in LHC Run 1

  • Nov 25, 2016
  • Modern Physics Letters A
  • William Barter
  • Supplementary Content

Search for the MSSM Neutral Higgs Boson in the $\mu^{+}\mu^{-}$ final state with the CMS experiment at LHC

  • Mar 07, 2014
  • AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna)
  • F Primavera
  • Research Article
  • Citations2

Silicon Sensors for the Upgrades of the CMS Pixel Detector

  • Dec 15, 2015
  • CERN Document Server (European Organization for Nuclear Research)
  • Matteo Centis Vignali
  • Conference Article
  • Citations1

Data preparation for the Compact Muon Solenoid experiment

  • Mar 18, 2014
  • Roberto Castello
  • Supplementary Content

WAN Emulation Development and Testing at Fermilab

  • Dec 01, 2004
  • University of North Texas Digital Library (University of North Texas)
  • A Bobyshev +4
  • PDF
  • Conference Article

Front-End control and monitoring system for the Resistive Plate Chambers at the CMS experiment

  • Oct 01, 2011
  • F Thyssen
  • PDF
  • Conference Article

Data Quality Monitoring of the CMS Tracker

  • Oct 01, 2009
  • V Adler
  • Research Article
  • Citations1

Detector Control System for the Electromagnetic Calorimeter of the CMS experiment

  • Jan 01, 2009
  • CERN Bulletin
  • P Adžić +18
  • PDF
  • Research Article
  • Citations4

Gaussian process regression as a sustainable data-driven background estimate method at the (HL)-LHC

  • Aug 06, 2025
  • The European Physical Journal C
  • Jackson Barr +1