• Cite Icon49
  • https://doi.org/10.1161/circulationaha.112.117143Copy DOI Icon

Optical Coherence Tomography

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Case presentation : A 56-year-old man presented to the hospital with chest pain and a non–ST-segment elevation myocardial infarction. Thrombotic plaque rupture in the left anterior descending coronary artery was treated with an everolimus-eluting stent. After stent deployment, angiography demonstrated the presence of a hazy opacity at the distal edge of the stent, and there was concern about a possible edge dissection. Optical coherence tomography (OCT) imaging of the opacity showed residual thrombus and no dissection. Subsequent aspiration thrombectomy and balloon dilation effectively treated the lesion without deployment of an additional stent. OCT is an intravascular imaging modality that utilizes near-infrared light to generate cross-sectional blood vessel images. OCT is similar to intravascular ultrasound (IVUS), and both OCT and IVUS provide information about intravascular anatomy that far exceeds the level of detail obtained from conventional contrast cineangiography. With the use of light rather than ultrasound reflectance, OCT generates in vivo images of coronary arteries and deployed stents with up to 10 to 15 μm of spatial resolution compared with the 100- to 200-μm resolution of IVUS. Although the spatial resolution of OCT is markedly superior to that of IVUS, near-infrared light does not penetrate tissue as effectively as sound, and therefore OCT imaging depths range from 1 to 3 mm into the vessel wall, whereas IVUS imaging depths range from 4 to 10 mm (Table). Additionally, near-infrared light is scattered by red blood cells, and therefore OCT imaging requires transient blood clearing during image acquisition. View this table: Table. Comparison of FD-OCT and IVUS The speed of light was initially a central challenge to developing a “clinically friendly” OCT system. Light travels too quickly for direct measurement of differential reflectance caused by vascular structures, and the original time delay OCT (TD-OCT) systems utilized a moving reference mirror to calibrate reflected light waves for image …

Similar Papers
  • Research Article
  • Citations1

Basic interpretation of intracoronary ultrasound and optical coherence tomography images: examples

  • Jun 01, 2016
  • Continuing Cardiology Education
  • M I Papafaklis
  • Research Article
  • Citations3

When the doctor needs an engineer to be the matchmaker

  • May 01, 2012
  • EuroIntervention
  • Pranav Patel +1
  • Research Article
  • Citations1232

Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound

  • Feb 01, 2002
  • Journal of the American College of Cardiology
  • Ik-Kyung Jang +12
  • Research Article
  • Citations169

Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention

  • Mar 01, 2013
  • JACC: Cardiovascular Interventions
  • Hiram G Bezerra +10
  • Research Article

The true character of lipid rich plaque by intravascular imaging: message from pathologist to cardiologist

  • Aug 02, 2013
  • European Heart Journal
  • H Hao +6
  • Research Article
  • Citations81

Frequency‐domain optical coherence tomography assessment of unprotected left main coronary artery disease—a comparison with intravascular ultrasound

  • Mar 16, 2013
  • Catheterization and Cardiovascular Interventions
  • Yusuke Fujino +10
  • Research Article
  • Citations22

Optical coherence tomography versus intravascular ultrasound to evaluate stent implantation in patients with calcific coronary artery disease

  • Dec 01, 2015
  • Open Heart
  • Ingibjorg Gudmundsdottir +9
  • Research Article
  • Citations117

The Role of Optical Coherence Tomography in Coronary Intervention

  • Jan 01, 2012
  • The Korean Journal of Internal Medicine
  • Mitsuyasu Terashima +2
  • Research Article
  • Citations4

Intravascular ultrasound and optical coherence tomography for the assessment of coronary artery disease and percutaneous coronary intervention optimization: Specific lesion subsets

  • May 01, 2018
  • Vijayakumar Subban +4
  • Dissertation

Investigation of low coherence interferometry techniques for biomedical applications

  • Jan 01, 2014
  • Tzu Hao Chow
  • Research Article
  • Citations173

Safety and Feasibility of an Intravascular Optical Coherence Tomography Image Wire System in the Clinical Setting

  • Jan 10, 2008
  • The American Journal of Cardiology
  • Tetsu Yamaguchi +12
  • Research Article
  • Citations7

Reciprocal assistance of intravascular imaging in three-dimensional stent reconstruction: Using cross-modal translation based on disentanglement representation.

  • Mar 01, 2023
  • Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
  • Peng Wu +6
  • Research Article
  • Citations12

Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology.

  • Jun 07, 2019
  • The international journal of cardiovascular imaging
  • Aiko Shimokado +13
  • Research Article
  • Citations5

Toward image quality assessment in optical coherence tomography (OCT) of rat kidney

  • Sep 05, 2020
  • Photodiagnosis and Photodynamic Therapy
  • Yuhong Fang +6
  • Research Article
  • Citations54

Images in cardiovascular medicine. Intracoronary imaging with optical coherence tomography: a new high-resolution technology providing striking visualization in the coronary artery.

  • Oct 29, 2002
  • Circulation
  • Eberhard Grube +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.