• https://doi.org/10.1117/3.898443.ch2Copy DOI Icon

Optical Systems With Circular Pupils

  • Aug 4, 2011
  • Virendra N Mahajan
Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

In this chapter, we consider the imaging properties of a system with a circular exit pupil by applying the general formulas derived in Chapter 1. We derive expressions for its point-spread function (PSF), optical transfer function (OTF), and encircled, ensquared, and excluded powers. The effect of aberrations on a PSF is first studied in terms of its central value, i.e., its Strehl ratio. An exact expression is obtained for the Strehl ratio and the results for primary aberrations are compared with those obtained from the approximate expressions based on the phase variance of the aberration across the pupil derived in Chapter 1. The tolerances for primary aberrations are given for a certain value of the Strehl ratio. Balanced primary aberrations are also discussed and they are identified with the Zernike circle polynomials. A defocused PSF is considered next, and it is shown that systems with large Fresnel numbers, such as photographic systems, have a very small depth of focus. However, systems with small Fresnel numbers, e.g., a laser transmitter, have a large depth of focus. Focused and collimated beams are discussed, and the concept of near- and far-field distances is introduced. It is shown that if the Fresnel number of the beam focused on a target is small, the axial irradiance is maximum at a point that is closer to the focusing optics. However, maximum central irradiance on a target at a given distance is obtained when a beam is focused on it, even though a larger irradiance is obtained at a closer point. Aberrated PSFs for rotationally symmetric aberrations are considered, and numerical results are obtained that show that the size of their central spot is practically independent of the aberration. Symmetry properties of the aberrated PSFs are considered next. Full PSFs for primary aberrations are shown graphically and pictorially. A brief comparison of the diffraction and geometrical PSFs is also given. The line of sight of an optical system is identified with the centroid of its PSF and discussed for aberrated systems. It is shown that only coma-type aberrations change the line of sight. The OTFs for primary aberrations are discussed, and the concept of contrast reversal is described. The OTF aberrated by coma is complex, and we give its real and imaginary parts as well as its modulus and phase. Aberration tolerances are given for a certain value of the Hopkins ratio. The geometrical OTF is also discussed and approximate expressions for it are obtained for the primary aberrations. It gives reasonably accurate results in the region of very low spatial frequencies, a region of practical interest when the MTF of an aberrated system at high frequencies is practically negligible. It is shown that the MTF averaged over all angular orientations of a spatial frequency vector is maximum when the standard deviation of the ray aberration [i.e., the root mean square (rms) radius of the spot diagram with respect to its centroid] is minimum. The diffraction OTF is shown to approach the geometrical OTF in the limit of zero wavelength. The differences between the diffraction and geometrical OTFs are summarized. The incoherent line- and edge-spread functions are discussed, and numerical results for both the aberration-free and the aberrated systems are given. The aberration tolerances for a certain value of the Struve ratio are also given.

Similar Papers
  • Research Article
  • Citations35

Phase transfer and point-spread function of the human eye determined by a new asymmetric double-pass method.

  • Nov 01, 1995
  • Journal of the Optical Society of America A
  • Rafael Navarro +1
  • Conference Article

Design of CMOS-APS smart imagers with mixed signal processing and analysis of their transfer characteristics

  • Aug 31, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Karel Fliegel +2
  • Research Article

Comparison of point spread function in myopia treated by LASIK and RGPCL

  • Oct 25, 2011
  • Chinese Journal of Optometry & Ophthalmology
  • Jun Jiang +3
  • Research Article
  • Citations3

Effects of processing steps with an edge image on determining the presampled modulation transfer function

  • Jul 01, 2012
  • Journal of the Korean Physical Society
  • Ye-Seul Kim +2
  • Research Article
  • Citations3

Effects of truncated Gaussian beam on the performance of fiber optical synthetic aperture system

  • May 01, 2012
  • Optoelectronics Letters
  • Li Liu +2
  • Conference Article

Ultraresolution of microwave, color, and synthetic color images

  • Nov 10, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Evgeni N Terentiev +2
  • Research Article
  • Citations79

Quantitative performance of bifocal and multifocal intraocular lenses in a model eye: point spread function in multifocal intraocular lenses.

  • Jan 01, 2002
  • Archives of Ophthalmology
  • Stefan Pieh
  • Conference Article
  • Citations10

Novel algorithm for measuring the MTF of a digital radiographic system with a CCD array detector

  • Apr 25, 2000
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xinhua Cao +2
  • Research Article
  • Citations5

Error analysis of the Golay3 optical imaging system

  • Apr 22, 2013
  • Applied Optics
  • Quanying Wu +4
  • Conference Article
  • Citations13

Automatic MTF measurement through a least square method

  • Nov 04, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Christophe Latry +2
  • Book Chapter

Aberration Analysis for the Computing Optical Design Method

  • Jan 01, 2017
  • Xiaopeng Shao +3
  • Research Article
  • Citations10

Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis

  • Aug 30, 2022
  • Ophthalmology and Therapy
  • Andreas F Borkenstein +2
  • Research Article
  • Citations2

An Experimental Comparison Of Directly And Indirectly Derived Modulation Transfer Functions

  • Mar 01, 2015
  • The Photogrammetric Record
  • Chia‐Hsiang Yang +4
  • Research Article
  • Citations305

Properties of a Defocused Optical System*

  • Oct 01, 1969
  • Journal of the Optical Society of America
  • Per A Stokseth
  • Research Article

Higher order aberration of polychromatic light with blue light filtering and clear intraocular lenses based on the schematic eye

  • Nov 25, 2012
  • Chinese Journal of Optometry & Ophthalmology
  • Yuan‐Yuan Wang
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.