  • Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model.
  • Cite Icon33
  • https://doi.org/10.1002/mp.12004Copy DOI Icon

Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Contrast-enhanced (CE) breast imaging involves the injection contrast agents (i.e., iodine) to increase conspicuity of malignant lesions. CE imaging may be used in conjunction with digital mammography (DM) or digital breast tomosynthesis (DBT) and has shown promise in improving diagnostic specificity. Both CE-DM and CE-DBT techniques require optimization as clinical diagnostic tools. Physical factors including x-ray spectra, subtraction technique, and the signal from iodine contrast, must be considered to provide the greatest object detectability and image quality. We developed a cascaded linear system model (CLSM) for the optimization of CE-DM and CE-DBT employing dual energy (DE) subtraction or temporal (TE) subtraction. We have previously developed a CLSM for DBT implemented with an a-Se flat panel imager (FPI) and filtered backprojection (FBP) reconstruction algorithm. The model is used to track image quality metrics - modulation transfer function (MTF) and noise power spectrum (NPS) - at each stage of the imaging chain. In this study, the CLSM is extended for CE breast imaging. The effect of x-ray spectrum (varied by changing tube potential and the filter) and DE and TE subtraction techniques on breast structural noise was measured was studied and included as a deterministic source of noise in the CLSM. From the two-dimensional (2D) and three-dimensional (3D) MTF and NPS, the ideal observer signal-to-noise ratio (SNR), also known as the detectability index (d'), may be calculated. Using d' as a FOM, we discuss the optimization of CE imaging for the task of iodinated contrast object detection within structured backgrounds. Increasing x-ray energy was determined to decrease the magnitude of structural noise and not its correlation. By performing DE subtraction, the magnitude of the structural noise was further reduced at the expense of increased stochastic (quantum and electronic) noise. TE subtraction exhibited essentially no residual structural noise at the expense of increased quantum noise, even over that of the DE case. For DE subtraction, optimization of dose weighting to the HE view (fh ) results in the minimization of quantum noise. Both subtraction weighting factor (wSub ) and the iodine contrast signal were dependent on the LE and HE x-ray spectra. To best detect a 5 mm Gaussian lesion with 5 mg/ml of iodine within a 4 cm thick breast, it was found that the high energy (HE) view should be acquired with a tube potential of 47 kVp (W/Ti spectrum) and the low energy (LE) view with a potential of 23 kVp (W/Rh spectrum). Due to the complete removal of structural noise, TE subtraction produced much higher d' than DE subtraction both as a function of mean glandular dose and iodine concentration. We have shown the effect of increasing x-ray energy as well as projection domain subtraction on breast structural noise. Further, we have exhibited the utility of the CLSM for DE and TE subtraction CE imaging in the optimization of imaging parameters such as x-ray energy, fh , and wSub as well as guiding the understanding of their effects on image contrast and noise.

Similar Papers
  • Conference Article
  • Citations11

A 3D linear system model for the optimization of dual-energy contrast-enhanced digital breast tomosynthesis

  • Mar 03, 2011
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yue-Houng Hu +1
  • Book Chapter

Application of a Dynamic 4D Anthropomorphic Breast Phantom in Contrast-Based Imaging System Optimization: Dual-Energy or Temporal Subtraction?

  • Jan 01, 2012
  • Nooshin Kiarashi +4
  • Research Article
  • Citations62

Improved detection of lung nodules by using a temporal subtraction technique.

  • Jul 01, 2002
  • Radiology
  • Shingo Kakeda +6
  • Research Article

Image quality comparison of synthesized two-dimensional images and digital mammography in breast tomosynthesis: A quantitative analysis.

  • Apr 01, 2026
  • Journal of applied clinical medical physics
  • Kazumi Sogabe +3
  • Research Article

TH‐C‐332‐07: Dual Energy Contrast‐Enhanced Breast Computed Tomography: A Phantom Study

  • Jun 01, 2008
  • Medical Physics
  • H Le +2
  • Research Article
  • Citations70

Dual-energy contrast-enhanced digital breast tomosynthesis – a feasibility study

  • Jun 08, 2009
  • The British Journal of Radiology
  • A-K Carton +5
  • Research Article
  • Citations35

Dual energy imaging using a clinical on-board imaging system

  • Jun 04, 2013
  • Physics in Medicine and Biology
  • M A Hoggarth +6
  • Research Article

TU‐CD‐204‐02: Measuring CT Slice Profile and Characterizing Automatic Tube Current Modulation

  • Jun 01, 2015
  • Medical Physics
  • J Fan
  • Research Article
  • Citations10

Challenges associated with the incorporation of digital radiography into a picture archival and communication system.

  • May 01, 1999
  • Journal of Digital Imaging
  • Eliot L Siegel +1
  • Conference Article
  • Citations23

Pipeline for effective denoising of digital mammography and digital breast tomosynthesis

  • Mar 09, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Lucas R Borges +4
  • Research Article
  • Citations3

The performance of digital x‐ray imaging systems in detection of subtle lung nodules

  • Oct 01, 1998
  • Medical Physics
  • Ehsan Samei
  • Research Article

WE-C-304A-08: The Instrumentation Noise Equivalent Exposure (INEE): Including Conversion, Secondary Quantum, Structure and Electronic Noise

  • Jun 01, 2009
  • Medical Physics
  • A Kuhls-Gilcrist +2
  • Single Report

Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

  • Nov 01, 2009
  • Christina M Li +2
  • Research Article

Modulation transfer function (MTF) and noise power spectrum (NPS) studies on three industrial digital radiography (IDR) systems

  • Jun 01, 2009
  • Insight - Non-Destructive Testing and Condition Monitoring
  • K A Mohd Salleh +2
  • Research Article
  • Citations25

Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study

  • Feb 01, 2011
  • Physics in Medicine & Biology
  • Tong Xu +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.