• Home
  • Search
  • Optimization of Outflow-Tract Ventricular Arrhythmia Ablation Using a Universal Right Ventricle Model
  • https://doi.org/10.3390/jcdd12090323Copy DOI Icon

Optimization of Outflow-Tract Ventricular Arrhythmia Ablation Using a Universal Right Ventricle Model

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Introduction: The radiofrequency catheter ablation (RFCA) of ventricular arrhythmias (VAs) originating from the right ventricular outflow tract (RVOT) is a well-established therapy. Traditionally, RFCA is guided using electroanatomical 3D mapping systems involving manual catheter navigation within cardiac chambers. While effective, this approach may be time-consuming, and it carries a potential risk of cardiac wall perforation. Although the risk is low, it cannot be underestimated. Therefore, alternative mapping methods are sought to reduce procedural times and improve the overall efficiency of RVOT-VAs ablation. Aim: To evaluate the safety, feasibility, and efficacy of a universal RVOT 3D model implementation for the ablation of idiopathic RVOT-VAs. Methods: Consecutive patients undergoing VA ablation supported with a universal RVOT 3D model (3D-MODEL group) were included in the study. The RVOT universal model in this group was created by processing DICOM images for the improved segmentation of anatomical structures, followed by production using 3D printing technology. Patients who underwent classic endocardial electroanatomical mapping served as controls (EAM group). Results: A total of 228 patients were included in the study (143 women, age 50 ± 17 years): 149 in the 3D-MODEL group and 79 in the EAM group. The acute complete elimination of clinical VAs was achieved for 133 (89%) of patients in the 3D-MODEL group vs. 65 (82%) in the EAM group (p = 0.14). The procedural time was significantly shorter in the 3D-MODEL group compared to the EAM group (38 ± 14 min vs. 80 ± 39 min, p < 0.001). A significant difference was also observed in the radiofrequency time between the 3D-MODEL and EAM groups (251 ± 176 s vs. 503 ± 425 s, p < 0.001). No significant difference in fluoroscopy time was found between the groups (284 ± 167 s vs. 260 ± 327 s, p = 0.49). Two cases of cardiac tamponade occurred, both in patients from the EAM group. During follow-up, lasting 14 ± 10 months, 87% of patients in the 3D-MODEL group and 75% in the EAM group remained arrhythmia-free (p = 0.45). Conclusions: The use of universal RVOT 3D modeling is a feasible, safe, and effective alternative to classic electroanatomical mapping in the ablation of idiopathic RVOT-VAs.

Similar Papers
  • Research Article
  • Citations17

Radiation exposure in the treatment of pediatric supracondylar humerus fractures.

  • Aug 07, 2019
  • Archives of Orthopaedic and Trauma Surgery
  • Alex Schmucker +4
  • Research Article

Idiopathic right ventricular outflow tract arrhythmia: gender difference in the origin of ventricular arrhythmia and influence factors of ablation results

  • Apr 28, 2018
  • Chin J Cardiac Arrhyth
  • Gang Chen +4
  • Research Article

Low-fluoro workflows and impact in radiation exposure in the electrophysiology lab

  • May 24, 2021
  • EP Europace
  • V Ferreira +13
  • Research Article

Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract: A Case Report.

  • Oct 01, 2015
  • Medicine
  • Li Yue-Chun +2
  • Research Article

Performance of surface electrocardiographic vectors in differentiating ventricular arrhythmia originating from coronary cusp, peri-pulmonic valve and right ventricular outflow tract

  • Aug 02, 2013
  • European Heart Journal
  • F Syed +9
  • Research Article
  • Citations50

Safety of radiofrequency catheter ablation without coronary angiography in aortic cusp ventricular arrhythmias.

  • Apr 13, 2014
  • Heart Rhythm
  • Kurt S Hoffmayer +8
  • Research Article
  • Citations23

Electroanatomic mapping systems (CARTO/EnSite NavX) vs. conventional mapping for ablation procedures in a training program.

  • Nov 12, 2015
  • Journal of Interventional Cardiac Electrophysiology
  • Jorge Romero +11
  • Research Article
  • Citations33

Reasons for failed ablation for idiopathic right ventricular outflow tract-like ventricular arrhythmias

  • May 22, 2013
  • Heart Rhythm
  • Miki Yokokawa +10
  • Research Article

Abstract 21364: Multicenter Prospective Study Comparing Phased Multipolar versus Traditional Radiofrequency Ablation

  • Nov 14, 2017
  • Circulation
  • Zahra Azizi +11
  • Discussion
  • Citations6

Ventricular Arrhythmias Linked to the Left Ventricular Summit Communicating Veins: A New Mapping Approach for an Old Ablation Problem.

  • Jan 01, 2018
  • Circulation: Arrhythmia and Electrophysiology
  • Daniele Muser +1
  • Research Article

YIA Abstracts: Best abstracts on clinical studies

  • Jun 01, 2009
  • Europace
  • Christian Veltmann +20
  • Research Article

Validation of an electrocardiographic marker of low voltage areas in the right ventricular outflow tract in patients with idiopathic ventricular arrhythmias.

  • Aug 21, 2022
  • Journal of Cardiovascular Electrophysiology
  • Leonor Parreira +9
  • Research Article
  • Citations3

Validation of a clinical model for predicting left versus right ventricular outflow tract origin of idiopathic ventricular arrhythmias.

  • Aug 24, 2023
  • Pacing and clinical electrophysiology : PACE
  • Luc Bourquin +16
  • Research Article
  • Citations1

Cryoablation of ventricular tachycardia using ultra-low temperature technology: acute success and insights from the post-interventional CMR

  • May 24, 2024
  • Europace
  • B Dinov +6
  • Research Article
  • Citations1

Retrospective study of the electrophysiological characteristics and criteria of ablation target for ventricular arrhythmia originating from right ventricular outflow tract

  • Dec 28, 2018
  • Chin J Cardiac Arrhyth
  • Peng Yang +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.